• Title/Summary/Keyword: Tube angle

Search Result 464, Processing Time 0.025 seconds

Heat Transfer Characteristics of a Horizontal Fin Tube in a Fluidized Bed Combustor (유동층 연소로 내에서 수평전열관의 열전달 특성에 관한 연구)

  • 맹민재;정준기;정태용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2365-2372
    • /
    • 1995
  • The objective of this study is to get the basic data for the development of fluidized bed combustor. For this purpose, various rake angles(.theta.=20.deg., 25.deg., 30.deg., 35.deg.) of finned tubes and a smooth tube were installed horizontally in the fluidized bed combustor of 410*250mm. The effect of fluidized bed temperature, superficial velocity in bed, size of bed materials, rake angle of finned tubes on the heat transfer coefficient was experimentally investigated. The following results were obtained. (1) Under the fluidized bed temperature(750.deg. C-900.deg. C), and the gas velocity in bed(1.1-2.8m/sec), The highest heat transfer coefficient was measured with the rake angle of finned tubes was .theta.=25.deg. and .theta.=35.deg. for the average fluidized material particle size of 1.22mm and 1.54mm, respectively. Generally, the heat transfer coefficient of finned tubes is 1.4 to 2.4 times larger than that of smooth tubes. (2) The size of bed materials influences the rake angle of finned tubes which can have the highest heat transfer coefficient. As the temperature in bed gets higher, the effect of the rake angle of finned tubes on the heat transfer coefficient becomes greater.

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Study on development of Solar Collector using Oscillating Capillary Tube Heat Pipe (진동세관형 히트파이프를 이용한 태양열 집열기 개발에 관한 기초연구(I);작동유체의 내부 충진율과 경사각도의 영향)

  • Kim, Tae-Hoon;Kim, Jong-Soo;Ha, Soo-Jung;Im, Yong-Bin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1394-1399
    • /
    • 2004
  • Recently solar energy is representative in the technology development and spread of alternative energy. Specially in condition of solar collectors, they have had very various shape. This paper reports experimental study about the application of Oscillating Capillary Tube Heat Pipe to flat-plate solar collector. In conclusion, overall temperature distribution of OCHP was investigated by charging ratio and inclination angle. Respective charging ratio is 15%, 20%, 40% and respective inclination angle is horizontal, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, perpendicular. As a result of experiment, charging ratio 20% heat pipe has shown the most uniform temperature distribution and also performance of heat transfer has been the best.

  • PDF

A study of beam hardening effect reduction occur in brain CT (Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구)

  • Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8479-8486
    • /
    • 2015
  • This study aim is occur in brain CT cause of beam hardening effect and reducing method, We will scan Bone opaque bead phantom on variation of image on the influence factor with equipment called 'Samatom Senation 16' with following listed herein : tube voltage, tube current, slice thickness, gantry angle, base line which affect beam-hardening effect. After that we are going to start Quantitative Analysis resulted in previous scanning and Qualitative Assessment with CT image sheet evaluation. result of quantitative analysis 140kVp $31.56{\pm}2.89HU$ on tube voltage, 150mA $-3.87{\pm}0.12HU$ on tube current, 3mm on slice thickness, and $13.31{\pm}1.03HU$ IOML on gantry angle which was the least beam-hardening effect. Like Qualitative Analysis, we went through Qualitative Assessment and most of valuers got a result of 140kVp on tube voltage, 150mA on tube current, 3mm on slice thickness. As before valuers evaluated gantry angle that scanned image from IOML or OML was the least beam-hardening effect occured. There are meaningful differences when we compare all theses factors statistically(P<0.05). therefore We consider that Minimizing artifact that caused by beam-hardening effect can provide better quality of image to deciphers and patients. if we rise tube voltage in permissible dose limit, set tube current in a limit that does not effect to image quality, use slice thickness too thin enough to harm resolution, use IOML or OML on gantry angle.

An Upper Bound Solution of Tube Drawing (관인발의 상계해석)

  • 엄경근;이동녕
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.03b
    • /
    • pp.40-47
    • /
    • 1996
  • An upper bound solution of tube drawing process using a fixed tapered plug has been obtained , which reduces to an solution for tube sinking by setting friction factor between tube and plug at zero. Effects of various process paraments have been discussed based on the solution.

  • PDF

Effect of Punch Shapes on Failure Instability of Expansion Tube (펀치형상이 팽창튜브의 파단불안전성에 미치는 영향)

  • Choi, Won-Mok;Kwon, Tae-Su;Jung, Hyun-Sung;Kim, Jing-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 2011
  • The rupture of an expansion tube is mainly affected by the expansion ratio and the external shape of the punch used to expand the tube. In order to prevent the tube from rupture, the effect of the external shape of the punch should be considered in the design. The aim of this paper is to confirm the effect of key design parameters of the punch on rupture of the tube using a finite element analysis with a ductile damage model. The results of the analysis indicated that the expansion ratio of the tube was mainly affected by variation of the radius of the punch. However, the rupture was more affected by variation of the punch angle than the radius of the punch. The existence of a specific punch angle at which rupture did not occur, even if the radius of the punch was increased, was found from the results.

Measurement of Average Pool Boiling Heat Transfer Coefficient on Near-Horizontal Tube (수평 가까운 튜브 표면의 평균 풀비등 열전달계수의 측정)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • An experimental study is performed to obtain an average heat transfer coefficient around the perimeter of a near horizontal tube. For the test a stainless steel tube of 50.8 mm diameter submerged in water at atmospheric pressure is used. Both subcooled and saturated pool boiling conditions are considered and the inclination angle of the tube is changed from the horizontal position to $9^{\circ}$ in steps of $3^{\circ}$. In saturated water, the local boiling heat transfer coefficient at the azimuthal angle of $90^{\circ}$ from the tube bottom can be regarded as the average of the coefficients regardless of the tube inclination angles. However, when the water is subcooled the location for the average heat transfer coefficient depends on the inclination angle and the heat flux. It is explained that the major mechanisms changing the heat transfer are closely related with the intensity of the liquid agitation and the generation of big size bubbles through bubble coalescence.

Strength Characteristics of Square Concrete Column Confined by Carbon Composite Tube (탄소섬유튜브로 횡구속된 각형 콘크리트 기둥의 압축강도 성능에 관한 연구)

  • 홍원기;김희철;윤석한;박순섭
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The carbon composite tube can play an important role in replacing or complementing longitudinal and transverse reinforcing steels by providing ductility and strength for conventional columns. In this study, both the experimental and analytical investigations of axial behavior of large-scale square concrete columns confined by carbon composite tube are presented. The specimens are filament-wound carbon composite with 90$^{\circ}$+30$^{\circ}$, 90$^{\circ}$+45$^{\circ}$ winding angle respect to longitudinal axis of tube. The instrumented large-scale concrete-filled composite tubes(CFCT) are subjected to monotonic axial loads exerted by 10,000kN UTM. The influence of winding angle, thickness of tube on stress-strain relationships of the confined columns is identified and discussed. Proposed equations to predict both the strength and ductility of confined columns by carbon composite tube demonstrate good correlation with test data obtained from large-scale specimens.

Development of Empirical Correlation to Calculate Pool Boiling Heat Transfer Coefficient on Inclined Tube Surface (경사진 튜브 표면의 풀비등 열전달계수 계산을 위한 실험식 개발)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.527-533
    • /
    • 2016
  • A new empirical correlation was developed to identify the effect of an inclination angle on pool boiling heat transfer coefficient of a tube submerged in the saturated water at atmospheric pressure. Through the experiments and the survey of published results 431 data points were obtained and the nonlinear least square method was used as a regression technique. The heat flux of the tube($0{\sim}120kW/m^2$), inclination angle($0^{\circ}{\sim}90^{\circ}$), and the length divided by the diameter of a tube(18~42.52) were selected as major parameters. The newly developed correlation well predicts the experimental data within ${\pm}18%$, with some exceptions.

Experimental study of heat transfer and pressure drop characteristics for flow of water inside circular smooth and micro-fin tubes (평활관 및 미세휜관 내에서의 물을 이용한 열전달 및 압력강하 특성에 관한 실험)

  • Park, H.B.;You, S.M.;Youn, B.;Yoo, K.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.454-461
    • /
    • 1997
  • Heat transfer and pressure drop for single phase flow of water in circular smooth and micro-fin tubes are measured. Copper tubes of 9.52 and 7mm outer diameter were used. The internal roughness in micro-fin tubes was formed by spiral grooves having $25^{\circ}$ helx angle, 0. 12mm fin height and 0.454mm pitch in 9.52mm tubes; $18^{\circ}$ helix angle, 0.15mm fin height and 0.322mm pitch in 7mm tubes. The measured friction factor and heat transfer coefficient are compared with relevant previous works, and the correlations for micro-fin tube are developed.

  • PDF