• 제목/요약/키워드: Tripping

검색결과 124건 처리시간 0.022초

트리핑 와이어가 설치된 원형실린더 주위의 유동현상 연구 (Experimental Study on the Flow around a Circular Cylinder with Tripping Wires)

  • 류병남;부정숙;조민기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.413-422
    • /
    • 2004
  • The flow characteristic in the wake around a circular cylinder with tripping wires, which was set in constant distance, was experimentally investigated in the uniform flow, Re=2.92$\times10^4$. The measurement of velocity vector and pressure distribution are carried out various angles of tripping wires in the range of $50^(\circ)$ to $80^(\circ)$ with $10^(\circ)$ interval. The results show that velocity profiles and pressure distributions are different with angles of tripping wires. The drag of the circular cylinder was decreased about 60% maximum when tripping wires' angle was $50^(\circ)$. The lowest reduction of the velocity and wake width was occurred by coanda effect when the angle was $60^(\circ)$, and the vortex shedding periodicity become rare at the same time.

복수 트리핑 와이어를 사용한 평판에서의 열전달 촉진에 관한 연구 (A Study on Heat Transfer Enhancement from Flat Plate Using Multiple Tripping Wires)

  • 유성연;조웅선;안종규
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.837-845
    • /
    • 2012
  • The purpose of this research is to investigate the heat transfer enhancement by the multiple tripping wires installed on a flat plate. Naphthalene sublimation technique is used to measure the local mass transfer coefficients, and then heat transfer coefficients are calculated using heat/mass transfer analogy. Experiments are performed for the developed and developing flow conditions. Local and average heat transfer coefficients from the flat plate with three tripping wires are compared with those of no and one tripping wire. Remarkable heat transfer enhancements are found resulting from the boundary layer separation by the tripping wires, especially in the laminar boundary layer.

트리핑 와이어를 사용한 평판에서의 국소물질전달 특성에 관한 실험적 연구 (Experimental Study on Local Mass Transfer Characteristics of Flat Plate Using Tripping Wire)

  • 유성연;조웅선;조우식
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.285-292
    • /
    • 2013
  • 본 연구의 목적은 평판의 선단에 설치된 트리핑 와이어에 의한 경계층 박리가 층류에서 난류로의 천이에 미치는 영향과 그 결과로 발생하는 물질전달에 미치는 영향을 규명하는 것이다. 나프탈렌승화법을 사용하여 평판에서의 국소물질전달계수를 측정하였으며, 유동 경계층의 효과를 평가하기 위해 발달된 유동과 발달하는 유동의 조건에서 트리핑 와이어가 설치된 평판에서의 국소물질전달계수를 설치되지 않은 평판에서의 값과 비교하였다. 발달하는 유동에서 국소물질전달계수가 변화하는 경향은 트리핑 와이어가 설치된 평판과 설치되지 않은 평판이 비슷하지만 발달된 유동에서는 상당히 다르게 나타났다. 평균 Sherwood 수는 경계층 박리로 인하여 트리핑와이어가 설치된 평판이 설치되지 않은 평판에 비해서 훨씬 높았다.

관의 입구구간에 있어서 Tripping Wire의 효과 (제 2 보, 실험적 연구) (Effects of Tripping Wire on Entrance Regions of a Duct (Part 2: Experimental Study))

  • 박승덕;문명국
    • 기계저널
    • /
    • 제16권3호
    • /
    • pp.277-283
    • /
    • 1976
  • An analytical study on the effects of initial turbulence intensities and Reynolds Number on the transition flow of a circular tube is conducted in Part I;Analysis of Transition Flow. In this second report, however, the effects of tripping wire on the developing regions of a horizontal pipe are studied experimentally and the results of analytical and experimental studies are compared. The agreements between the two results are relatively good. The diameter of the apparatus tube in the experimental works is 76.25mm. and the length is about 7m. The tripping wire diameters used in the experiments are 1.0,1.5,2.0,2.5mm., etc. From the experimental works, the relations between tripping wire size; o.e., diameter and Reynolds Number are proposed for the given thbe diameter.

  • PDF

A Novel SIME Configuration Scheme Correlating Generator Tripping for Transient Stability Assessment

  • Oh, Seung-Chan;Lee, Hwan-Ik;Lee, Yun-Hwan;Lee, Byong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1798-1806
    • /
    • 2018
  • When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.

Tripping wire가 부착된 회전원주에 의한 난류휴류의 응집구조 (Coherent Structures of Turbulent Wake Past a Rotating Circular Cylinder with a Tripping Wire)

  • 부정숙;이종춘
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1927-1939
    • /
    • 1995
  • An experimental investigation is conducted to find out the large scale coherent structures in the intermediate wake past a rotating cylinder with a single tripping wire attached. Relation between the vortex shedding frequency and the spin rate of rotating cylinder and the effects of the tripping wire on the flow characteristics were studied by using spectral analysis and conditional phase average technique, respectively. It is found that the vortex shedding frequency is bound to a certain range and varies regularly as spin rate increases. The coherent structures are compared with those of the plain rotating cylinder in the case of spin rate of 1.0. Distance between the upper and lower center of vortices increase and the vortex shedding time is delayed, the velocity fluctuation energy decreases near the center line of vortices and it spreads out to the outer region. The Reynolds shear stress increases highly in the upper region and the turbulent wake width expands with strong entrainment process.

고조파가 누전차단기에 미치는 영향 (Effect of Harmonics on Residual Current Protective Devices)

  • 전정채;이상익;유재근
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.84-89
    • /
    • 2006
  • 고조파에 의한 누전차단기 동작이 계속적으로 보고되어 왔으나 누전차단기 동작을 설명할 수 있는 자료가 없는 실정이다. 본 논문에서는 누전차단기에 대한 고조파 영향을 규명하기 위해 누전차단기 오동작 현황에 대한 조사 및 누전차단기 원인불명 동작이 자주 발생하는 건물에서 고조파를 측정 및 분석하였다. 또한 왜곡된 파형을 발생시킬 수 있는 고조파 합성장치를 이용하여 누전차단기 동작 특성을 시험하였다. 시험결과 3차 고조파가 기본파에 합성되었을 때 가장 작은 값의 누설전류에 누전 차단기가 동작되었고 기본파에 더해진 고조파 차수가 증가할 수 록 누전차단기 동작전류는 증가하였다.

배선용 및 누전차단기 오동작 실태조사 (A Survey on the Actual Conditions of False-Tripping of MCCB ard ELB)

  • 유재근;이상익;전정채;정종욱;임용배
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.223-227
    • /
    • 2004
  • False-tripping of MCCB(Molded Case Circuit Breaker) and ELB(Earth Leakage Circuit Breaker), using to protect overload and ground-fault accidents in power system raise direct and indirect losses like as information loss, facilities damage, slipup of goods production in industry place. Cause of false-tipping of MCCB and ELB is various and cause analysis of false-tripping is mostly made up by inference because trip is not reappeared. This paper investigated and analyzed causes and influences of false-tripping of MCCB and ELB by making up a question to safety managers of two hundred and eighteen electrical facilities for private use. Also, the necessity of experimental study on the effect of harmonics on false-tipping of MCCB and ELB was presented.

  • PDF

역압력 구배가 존재하는 난류 경계층의 발달에 트리핑 구조물이 미치는 영향에 관한 연구 (The effects of tripping structure on the development of turbulent boundary layer subjected to adverse pressure gradient)

  • 임태현;김대성;윤순현
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.36-44
    • /
    • 2001
  • The effects of various tripping structures on turbulent boundary layer subjected to adverse pressure gradient were examined. The profiles are compared to zero pressure gradient and adverse pressure gradient. The increases of tripping structures of height, k are affects almost flow parameter included velocity fluctuation, skin friction coefficient and turbulent boundary thickness.

  • PDF

누전차단기의 설계와 제작 (Ground fault circuit interrupter design)

  • 설승기
    • 전기의세계
    • /
    • 제29권5호
    • /
    • pp.303-311
    • /
    • 1980
  • The hazards of electrical shock are well known, but the conventional ground fault circuit breakers did not provide the statis factory safety for human body. Thus this paper considers the standards of performance that they must meet, and describes the new tripping mechanism the operations and the improvements. The experiment at new G.F.C.I. indicates maximum tripping time 25msec minimum sensitive leakage current 25mA and maximum nonaperation leakage current 15mA.

  • PDF