• 제목/요약/키워드: Triple-Density

검색결과 83건 처리시간 0.036초

표준백금저항온도계를 이용한 온도측정능력 상호비교 (Inter-comparison of temperature measurement capability using standard platinum resistance thermometers)

  • 감기술;강주식;이용재;이광복;김용규;박승남
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Clinicopathologic Features of Breast Carcinomas Classified by Biomarkers and Correlation with Microvessel Density and VEGF Expression: A Study from Thailand

  • Chuangsuwanich, Tuenjai;Pongpruttipan, Tawatchai;O-charoenrat, Pornchai;Komoltri, Chulaluk;Watcharahirun, Suwapee;Sa-nguanraksa, Doonyapat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권3호
    • /
    • pp.1187-1192
    • /
    • 2014
  • Background: To correlate breast cancer subtypes with prognostic factors, microvessel density (MVD), vascular endothelial growth factor (VEGF) expression and clinical features. Materials and Methods: One hundred cases of primary breast carcinoma were classified using biomarkers on tissue microarray as: luminal A [estrogen receptor (ER)+, HER2-, $Ki-67{\leq}14%$], luminal B [ER+, HER2+ or ER+, HER2-, Ki-67>14%], HER2, triple negative basal-like (TNB) [any basal cytokeratins (CKs, 5, 14, 17) and/or endothelial growth factor receptor (EGFR) expression], and TN without such markers [TNN, null], and assessed for p53, vimentin, VEGF and CD31 immunoperoxidase. Results: Of the 100 cases (mean age, 51 years; mean tumor size, 3.2cm; 56% with nodal metastasis; 89 invasive ductal carcinomas, not otherwise specified, 4 invasive lobular carcinomas, 3 metaplastic carcinomas, and 4 other types) there were 39 luminal A, 18 luminal B, 18 HER2, 15 TNB and 10 TNN. The positivities of basal-like markers in the basal-like subtype were 78.3% for CK5, 40% for CK14, 20% for CK17, 46.7% for EGFR. There was no significant difference in age distribution, tumor size, degree of tubular formation, pleomorphism, lymphovascular invasion, nodal metastasis, MVD, VEGF expression and survival among subgroups. TNs demonstrated significantly higher tumor grade, mitotic count, Ki-67 index, p53 and vimentin and decreased overall survival compared with nonTN. Conclusions: The distribution of breast cancer subtypes in this study was similar to other Asian countries with a high prevalence of TN. The high grade character of TN was confirmed and CK5 expression was found to be common in our basal-like subtype. No significant elevation of MVD or VEGF expression was apparent.

미세혈관 문합 후 순환계 질환 개선을 위한 원적외선 치료기의 열적 특성 평가 (Evaluation of Thermal Properties for the Far Infrared Therapy After Microvascular Anastomosis for the Treatment of Circulatory Diseases)

  • 양영규;오승현;김철웅
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권2호
    • /
    • pp.179-186
    • /
    • 2013
  • 혈액순환촉진, 심혈관계치료, 피부질환, 암세포억제 등의 의료분야에 원적외선 치료법이 광범위하게 활용되고 있다. 본 연구에서는 원적외선 치료에 효과적인 패널형 방사체의 발열부에 대한 열적 특성을 실험적으로 분석하였다. 발열선은 정상상태에서 절연피복에 $150mW/m^2$의 열유속으로 열에너지를 공급하여 절연피복은 발열선 온도의 20%에 도달하였다. 단열막 사용은 약 20%의 발열판 표면온도 증가효과가 있었으며 열시상수를 상승시켜 혈액순환촉진에 크게 기여하는 것으로 나타났다. 발열선의 배치간격이 발열부 설계에 중요한 인자이며 열확산의 중첩을 위해 발열판의 열전도계수와 밀도를 고려해야함을 알 수 있었다.

캐올리나이트의 셰슘-137 및 스트론튬-90 흡착에 대한 삼중층 표면복합반응 모델링: 지하수 이온성분 및 pH의 영향 (Triple-layer Surface Complexation Modeling on the Adsorption of cs-137 and Sr-90 onto Kaolinite: Effect of Groundwater Ions and pH)

  • 정찬호;박상원;김수진
    • 한국광물학회지
    • /
    • 제11권2호
    • /
    • pp.106-116
    • /
    • 1998
  • The adsorption of Cs-137 and Sr-90 onto kaolinite in prescence of major groundwater cations (Ca2+, K+, Na+) with different concentrations was simulated by using triple-layer surface complexation model (TL-SCM). The site density (8.73 sites/nm2) of kaolinite used for TL-SCM was calculated from it's CEC and specific surface area. TL-SCM modeling results indicate that concentrations dependence on 137Cs and 90Sr adsorption onto kaolinite as a function of pH is best modeled as an outer-sphere surface reaction. This suggests that Cs+ and Sr2+ are adsorbed at the $\beta$-layer in kaolinite-water interface where the electrolytes, Nacl, KCl and CaCl2, bind. However, TL-SCM results on Sr adsorption show a discrepancy between batch data and fitting data in alkaline condition. This may be due to precipitation of SrCO3 and complexation such as SrOH+. Intrinsic reaction constants of ions obtained from model fit are as follows: Kintcs=10-2.10, KintSr=10-2.30, KintK=10-2.80, KintCa=10-3.10 and KintNa=10-3.32. The results are in the agreement with competition order among groundwater ions (K+>Ca2+>Na+) and sorption reference of nuclides (Cs-137>Sr-90) at kaolinite-water interface showed in batch test.

  • PDF

The nonlocal theory solution for two collinear cracks in functionally graded materials subjected to the harmonic elastic anti-plane shear waves

  • Zhou, Zhen-Gong;Wang, Biao
    • Structural Engineering and Mechanics
    • /
    • 제23권1호
    • /
    • pp.63-74
    • /
    • 2006
  • In this paper, the scattering of harmonic elastic anti-plane shear waves by two collinear cracks in functionally graded materials is investigated by means of nonlocal theory. The traditional concepts of the non-local theory are extended to solve the fracture problem of functionally graded materials. To overcome the mathematical difficulties, a one-dimensional non-local kernel is used instead of a two-dimensional one for the anti-plane dynamic problem to obtain the stress field near the crack tips. To make the analysis tractable, it is assumed that the shear modulus and the material density vary exponentially with coordinate vertical to the crack. By use of the Fourier transform, the problem can be solved with the help of a pair of triple integral equations, in which the unknown variable is the displacement on the crack surfaces. To solve the triple integral equations, the displacement on the crack surfaces is expanded in a series of Jacobi polynomials. Unlike the classical elasticity solutions, it is found that no stress singularities are present at crack tips.

$Pb(Zr_{0.56}Ti_{0.44})O_3$ 강유전체 음극의 전극 모형에 따른 전자 방출 특성 (Effect of Electrode Structures on Electron Emission of the $Pb(Zr_{0.56}Ti_{0.44})O_3$ Ferroelectric Cathode)

  • 서민수;홍기민
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.699-707
    • /
    • 2010
  • Electric-field-induced electron emission from the three kinds of $Pb(Zr_{0.56}Ti_{0.44})O_3$ ferroelectric cathodes with different electrode structure has been investigated. Regardless of the electrode structures, a threshold field of the each cathode was 2.5-2.6kV/mm, which is 3 times higher than the coercive field of $Pb(Zr_{0.56}Ti_{0.44})O_3$ material. Although the waveform of the electron currents was affected by the structure of the electrode, no significant difference for the emission properties such as the peak current and the pulse width was observed from the three kinds of the cathodes. However, the current density of the cathode was dependent on the electrode structure. From the simulation of electric field distribution, the surface flashover, and the injury region of the cathode surface, it was proved that the prime electrons were initiated at the electrode-ceramic-vacuum triple point by field emission and the emission currents were strongly enhanced by the surface plasma.

Li+ and Li+I-Li+ ions Solvated by 1,4-dioxane: An ion Mobility Spectrometry-Mass Spectrometry Study

  • Choi, Yunseop;Ji, Inyong;Seo, Jongcheol
    • Mass Spectrometry Letters
    • /
    • 제12권4호
    • /
    • pp.152-158
    • /
    • 2021
  • Electrospray ionization (ESI) and ion mobility spectrometry-mass spectrometry (IMS-MS) were employed to investigate the solvated structures of ionic species in the lithium iodide electrolyte solution in the gas phase. The Li+I-Li+ triple ion and single standalone Li+ ions solvated by 1,4-dioxane were successfully generated and observed by ESI-MS under the influence of dioxane vapor at the inlet region. Under the present experimental condition, (1,4-dioxane)m·Li+ complex ions (m = 1, 2, and 3) and a (1,4-dioxane)·Li+I-Li+ complex ion were observed, which were further examined by IMS to investigate their structures. The presence of multiple structural isomers was confirmed, which accounts for the endothermic conformational transition of 1,4-dioxane from a chair to a boat to achieve bidentate O-donor binding to Li+ and Li+I-Li+. Further structural details critical for the ion-solvent interactions were also examined and discussed with the help of density functional theory calculations.

Feasibility study of using triple-energy CT images for improving stopping power estimation

  • Yejin Kim;Jin Sung Kim ;Seungryong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1342-1349
    • /
    • 2023
  • The planning accuracy of charged particle therapy (CPT) is subject to the accuracy of stopping power (SP) estimation. In this study, we propose a method of deriving a pseudo-triple-energy CT (pTECT) that can be achievable in the existing dual-energy CT (DECT) systems for better SP estimation. In order to remove the direct effect of errors in CT values, relative CT values according to three scanning voltage settings were used. CT values of each tissue substitute phantom were measured to show the non-linearity of the values thereby suggesting the absolute difference and ratio of CT values as parameters for SP estimation. Electron density, effective atomic number (EAN), mean excitation energy and SP were calculated based on these parameters. Two of conventional methods were implemented and compared to the proposed pTECT method in terms of residuals, absolute error and root-mean-square-error (RMSE). The proposed method outperformed the comparison methods in every evaluation metrics. Especially, the estimation error for EAN and mean excitation using pTECT were converging to zero. In this proof-of-concept study, we showed the feasibility of using three CT values for accurate SP estimation. Our suggested pTECT method indicates potential clinical utility of spectral CT imaging for CPT planning.

Geometrical Characteristics and Atomic Charge Variations of Pd(II) Complexes [Pd(L)Cl2] with an Axial (Pd·O) Interaction

  • Park, Jong-Keun;Cho, Yong-Guk;Lee, Shim-Sung;Kim, Bong-Gon
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.85-89
    • /
    • 2004
  • Geometrical structures of [Pd(L)$Cl_2$] with oxathia macrocycles have been calculated using ab initio secondorder Moller-Plesset (MP2) and Density Functional Theory (DFT) methods with triple zeta plus polarization (TZP) basis set level. In optimized Pd(L)$Cl_2$ complexes, Pd(II) locates at the center surrounded by a square planar array of two sulfurs on an oxathia macrocycle and two chlorides. The endo-Pd(II) complexes with an axial (Pd${\cdots}$O) interaction are more stable than the exo-Pd(II) complexes without the interaction. In the endo-Pd(II) complexes, the atomic charge of the oxygen atom moves to Pd(II) via the axial ($Pd{\cdots}$O) interaction and then, the charge transfer from Pd(II) to the S-atoms occurs stepwise via ${\pi}$-acceptors of the empty d-orbitals.

혼합 이온 및 전자 전도체-프로톤 전도성 전해질 복합 공기극을 적용한 프로토닉 세라믹 연료전지의 전기화학적 성능 평가 (Electrochemical Evaluation of Mixed Ionic and Electronic Conductor-Proton Conducting Oxide Composite Cathode for Protonic Ceramic Fuel Cells)

  • 신형식;이진우;최시혁
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.48-55
    • /
    • 2024
  • The electrochemically active site of mixed ionic and electronic conductor (MIEC) as a cathode material is restricted to the triple phase boundary in protonic ceramic fuel cells (PCFCs) due to the insufficient of proton-conducting properties of MIEC. This study primarily focused on expanding the electrochemically active site by La0.6Sr0.4Co0.2Fe0.8O3-δ(LSCF6428)-BaZr0.4Ce0.4Y0.1Yb0.1O3-δ (BZCYYb4411) composite cathode. The electrochemical properties of the composite cathode were evaluated using anode-supported PCFC single cells. In comparison to the LSCF6428 cathode, the peak power density of the LSCF6428-BZCYYb4411 composite cathode is much enhanced by the reduction in both ohmic and non-ohmic resistance, possibly due to the increased electrochemically active site.