분산전원 계통 연계 전용선로에 설치된 보호 계전기의 정정에 관한 연구 (A Study on Correction of the Protective Relay Equipped in the Dedicated Line Used for Connecting Distributed Generators to Power Network)

  • 정종찬;장성일;최돈만;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.141-144
    • /
    • 2002
  • This paper describes the correction of the protective relay equipped in the dedicated line used for connecting distributed generators (DG) to power grid. The fault current measured in a relaying point might be changed according to the fault conditions. Generally, the fault current of the line to line fault or the line to ground fault at the dedicated line is much higher than the protective set value due to the large fault level. However. when the high impedance fault is occurred in the dedicated line, we may not detect it because its fault level can be lower than the generating capacity of DG. And, the protective relay with conventional set value may generate a trip signal for insertion of DG due to the large transient characteristics of generators. Through the various simulations such as the fault in the dedicated line and the insertion of DG, we show that it would be necessary to modify the protective relay set value for detecting the high impedance fault occurred in the dedicated line and for preventing the mis-operation of protective relay caused by the insertion of DG.

  • PDF

풍력발전단지 연계 전용선로 보호계전방식의 향상에 대한 연구 (A Study on the Improved Protective Relaying Algorithm Applied in the Linked System Interconnecting Wind Farm with the Utilities)

  • 장성일;김광호;권혁완;김대영;권혁진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.675-683
    • /
    • 2003
  • This paper describes the correction strategy of an overcurrent relay applied in the linked line for interconnecting wind farm with utility power networks in order to improve the capability of a fault detection. The fault current measured in a relaying point might vary according to the fault conditions. Generally, the current of the line to line fault or the line to ground fault in the linked line is much higher than the set value of protective relay due to the large fault level. However, when the high impedance fault occurs in the linked line, we can't detect it by conventional set value because its fault level may be lower than the generating capacity of wind farm. And, the protective relay with conventional set value may generate a trip signal for the insertion of wind turbine generators due to the large transient characteristics. In order to solve above problems and improve protective relaying algorithms applied in the linked line, we propose a new correction strategy of the protective relay in the linked line. The presented method can detect the high impedance fault which can't be detected by conventional relay set value and may prevent the mis-operation of protective relay caused by the insertion of wind farm.

선로 이용률 예측 기반의 동적 폴링 기법 (Dynamic Polling Algorithm Based on Line Utilization Prediction)

  • 조강홍;안성진;정진욱
    • 정보처리학회논문지C
    • /
    • 제9C권4호
    • /
    • pp.489-496
    • /
    • 2002
  • 본 논문에서는 선로의 이용률 예측을 기반으로 하여 폴링 주기를 동적으로 변경시킬 수 있는 새로운 폴링 기법을 제시한다. 폴링은 네트워크 모니터링의 가장 중요한 기능이지만, 네트워크가 congestion 상태일 때 과대한 폴링 데이터는 네트워크를 심각한 congestion 상태로 만든다. 따라서 기존의 여러 폴링 기법들이 이전 시점에 폴링 요청했을 때 수신한 응답 메시지의 Round Trip Time 또는 폴링한 값의 선로 이용률을 통해 네트워크 congestion 또는 에이전트의 로드 여부를 판단하여 폴링 주기를 변경하여 폴링 트래픽을 조절하였으나 이는 이전 시점의 폴링을 근거로 폴링 주기를 변경하는 기법이기 때문에 폴링하고자 하는 당 시점의 네트워크 상태를 반영하지 못한다. 본 논문에서 제시하는 기법은 과거의 데이터를 근거로 폴링 시점에 폴링 데이터가 폴링 경로 상의 선로 이용률 임계값을 위반하는지를 예측하여 이를 통해 폴링 주기를 변경시킨다. 본 논문에서는 Box-Jenkins의 AR (Autoregressive) 모델을 사용하여 네트워크를 구성하는 각 선로의 이용률을 예측하였고 임계값 위반 여부를 확률로 제시하였다. 또한, 제시한 선로 이용률 예측 기반의 동적 폴링 기법을 실제 네트워크에 적용하여 적합성 여부를 평가하였고, 실험을 통하여 적절한 수준의 선로 이용률 임계값과 임계값 위반 확률을 판단함으로써 본 기법의 성능을 최대화하였다.

주파수 안정도 유지를 위한 부하차단 시뮬레이션-가스분리플랜트 사례 (LOAD SHEDDING SIMULATION FOR MAINTAINING FREQUENCY STABILITY-GAS SEPARATION PLANT CASE)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.72_73
    • /
    • 2009
  • The industrial power system has the radial plant distribution system and domestic generators to supply the essential loads. When the system is isolated from the utility tie line, the system frequency drops resulting in the trip of generators. The load shedding scheme shall be properly designed to secure the essential load. In this paper two kinds of load shedding schemes, those are, the Fast Act Load Shedding(FALS) and Under Frequency Load Shedding(UFLS) are simulated and compared taking an example of petrochemical gas separation plant.

  • PDF

아시아 토목대회 및 일본 도로 교량건설 현장 시찰 (Civil Engineering Conference in the Asian Region, Visit to Several Road and Bridge Construction Site of Japan)

  • 장래섭
    • 기술사
    • /
    • 제34권4호
    • /
    • pp.17-29
    • /
    • 2001
  • After participating in the 2nd, Asian Civil Engineering Conference which is subjected by Japan, a trip of site during construction recent was done. The country Is being developed to use effectvely by the methods of aqua-line, truss suspersion bridge. double deck bridge, etc. The Japanese engineers have a pride to do their best for the construction In the given environment. 1 want to notify that our civil engineers must have the responsibility to develop the technical engineering, to make the useful country and to resolve the environmental problem via the oversea experience like as.

  • PDF

계통조건에 의한 거리계전기의 응동특성에 관한 연구 (A Study on the Operational Characteristic of Distance Relay According to Power System Condition)

  • 정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.290-293
    • /
    • 2001
  • This paper presents the reach accuracy of a distance relay for protection of transmission line according to power system conditions. The apparent impedance of distance relay is considerably affected by source impedance, load current, power factor, fault point and resistance etc. For protective coordination on the variables power system parameters, trip characteristics of distance relay at sending and receiving terminal are discussed.

  • PDF

배전자동화시스템의 효율적인 운용을 위한 구가기능 및 정보전송체계 (The Additional Functions and Data Transmission Flow Diagram for Effective Operation of Distribution Automation System)

  • 이중호;하복남;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.211-213
    • /
    • 1998
  • This paper introduces the additional remote monitoring and remote setting functions needed to operate the distribution automation system effectively. we compare the additional functions with the old functions. The remote setting of minimum trip value of fault indicator is an example of additional function. It saves time and line-man's power. Also this paper describes the data transmission flow diagram for operation of distribution automation system using wireless communication method.

  • PDF

서울 수도권 지하철 교통망 승객 흐름의 시각화 (Visualization of Passenger Flows of the Metropolitan Seoul Subway System)

  • 김호성;박종수;이금숙
    • 한국콘텐츠학회논문지
    • /
    • 제10권4호
    • /
    • pp.397-405
    • /
    • 2010
  • 본 연구는 서울 수도권의 지하철 교통망에서 승객들의 흐름을 찾아 시각화 방법을 제안하고 주요 업무지역의 출퇴근 승객 흐름을 분석한다. 지하철 승객 흐름은 대용량 시공간 데이터로서 일반적인 통계적 분석으로는 그 흐름의 본질을 분석하기가 매우 어렵다. 그러나 승객의 흐름을 시공간상에 역동적으로 시각화하여 보여주면 직관적인 분석이 가능할 뿐만 아니라 통행흐름의 특성을 보다 효과적으로 파악할 수 있다. 지하철 승객들의 대용량 교통카드 트랜잭션 데이터베이스로부터 제안된 방법으로 승객 흐름을 찾아 지하철 교통망의 각 링크의 흐름을 다양한 방법으로 시각화하여 주요 업무지역에서의 통행 행태를 직관적으로 분석하였다. 그 결과로 서울의 중심업무지역들과 지하철 노선과의 연관성이 매우 높고, 세 주요 중심업무지역들의 하루 지하철 승객흐름 양상에 뚜렷한 차이가 있음을 확인할 수 있었다.

광역철도 승차권제도 개선 및 효과에 관한 연구 (Study on the Improvement and Effect of the Metro Fare System)

  • 임철;이용상;윤경만
    • 한국철도학회논문집
    • /
    • 제16권6호
    • /
    • pp.482-491
    • /
    • 2013
  • 현재 운영 중인 광역철도 승차권은 교통카드와 정기권 등으로 매우 제한되어 있어, 소비자 선택에 한계가 있으며, 소비자 수요의 다양성을 고려한 승차권 제도 도입이 필요한 실정이다. 이에 외국 주요도시에서 사용 중인 다양한 승차권 제도 운영을 분석하여 우리나라 수도권 광역철도 승차권 제도가 보다 효율적으로 운영되는 방안을 제시하였다. 주요내용으로는 대중교통 이용 촉진 및 비용부담 감소, 수익증대의 효과로 이어질 수 있도록 하여 외국에서 일반화되어 있는 1일권 승차권, 승용차 출퇴근자의 승객과 승차인원 증대를 위한 출퇴근권 및 경춘선 등에 서비스가 공급대비 수요가 부족한 경우에 한해 왕복 여행객에 대한 특별할인 왕복승차권 제도 도입을 제안하였다.

고강도 강판 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향 (The Effect of Paint Baking on the Strength and Failure of Spot Welds for Advanced High Strength Steels)

  • 최철영;이동윤;김인배;김양도;박영도
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.967-976
    • /
    • 2011
  • Conventional fracture tests of resistance spot welds have been performed without consideration of the paint baking process in the automobile manufacturing line. The aim of this paper is to investigate the effect of the paint baking process on load carrying capacity and fracture mode for resistance spot welded 590 dual phase (DP), 780DP, 980DP, 590 transformation in duced plasticity (TRIP), 780TRIP and 1180 complex phase (CP) steels. With paint baking after resistance spot welding, the l-shape tensile test (LTT) and nano-indentation test were conducted on the as-welded and paint baked samples. Paint baking increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial interfacial fracture (PIF) to button fracture (BF). Improvement in fracture appearance after LTT is observed on weldments of 780 MPa grade TRIP steels, especially in the low welding current range with paint baking conditions. The higher carbon contents (or carbon equivalent) are attributed to the low weldability of the resistance spot welding of high strength steels. Improvement of the fracture mode and load carrying ability has been achieved with ferrite hardening and carbide formation during the paint baking process. The average nano-indentation hardness profile for each weld zone shows hardening of the base metal and softening of the heat affected zone (HAZ) and the weld metal, which proves that microstructural changes occur during low temperature heat treatment.