• Title/Summary/Keyword: Trigger

Search Result 1,481, Processing Time 0.027 seconds

Sequential Catalytic Combustion System (순차식 촉매연소 시스템)

  • 유상필;정남조;이승재;류인수;강성규;송광섭
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.197-200
    • /
    • 2004
  • Compared to conventional flame combustion, catalytic combustion had the advantage of oxidation of V.O.C. gas which was high voluminous, low caloric mixture flow. However, the temperature of mixture gas should be over the one of catalytic reaction start and the control of reaction on the catalytic surface tends to be vulnerable. To overcome these obstacles, composition of both catalytic combustor and heat exchanger was devised and named the sequential catalytic combustion system. In this system, only trigger unit needed preheating process for transient starting time. Once trigger unit was ignited, the next unit w3s supplied heat to ignite from that and same process was performed to the last one sequentially. When it come to steady state, whole mixture gas was oxidated at each unit simultaneously and preheating for trigger unit was not needed any more. System of 100 kcalh/hr capacity was devised and operated successfully.

  • PDF

Characteristics of High Voltage Discharge using Triggered Spark Gap (Trigged Spark Gap의 고전압 방전제어특성 연구)

  • Son, Yoon-Gyu;Kim, Kwang-Gi;Park, Sang-Wook;Cho, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1816-1818
    • /
    • 1997
  • A triggered sparkp gap switch was fabricater and its high-voltage discharge characteristics were studied. The switch is composed of two main electrodes and one trigger electrode which is placed perpendicular to the main one. Spark gap distance was fixed by 25 mm. This device has been operated without self firing at the pulse repetition frequency from 1 to 20 Hz limited by the charging current, and the hold-off voltage from 10 to 30kV. An IGBT switch and igniter coil (originally used in a car) were adopted for a trigger circuit. In this article preliminary switch characteristics of the spark gap switch are reported with the emphasis on the description of the trigger circuit.

  • PDF

Treatment Experience of Pulsed Radiofrequency Under Ultrasound Guided to the Trapezius Muscle at Myofascial Pain Syndrome -A Case Report-

  • Park, Chung-Hoon;Lee, Yoon-Woo;Kim, Yong-Chan;Moon, Joo-Hwa;Choi, Jong-Bum
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.52-54
    • /
    • 2012
  • Trigger point injection treatment is an effective and widely applied treatment for myofascial pain syndrome. The trapezius muscle frequently causes myofascial pain in neck area. We herein report a case in which direct pulsed radiofrequency (RF) treatment was applied to the trapezius muscle. We observed that the RF treatment produced continuous pain relief when the effective duration of trigger point injection was temporary in myofascial pain.

The Computer Simulation on the Characteristics of the Non-Inductive Superconducting Fault Current Limiter (무유도성 초전도전류제한기의 특성 해석 및 컴퓨터 시뮬레이션)

  • 주민석;이상진;오윤상;고태국
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1050-1060
    • /
    • 1994
  • This paper is a study on the computer simulation of the characteristics of the superconducting fault current limiter. Input variable parameters are apparent power, load resistance value, line resistance value and so on. Initial fault current 2 times larger than the trigger current is required to reduce the switching time of SFCL. The propagation velocity increases abruptly, the transport current is several times larger than the ciritical current. In this paper, the switching time is calculated to be 323$\mu$ sec, and the initial fault current is 19 times larger than the critical current. Because the trigger coils are bifilar winding, they have little impedance in superconducting state. After fault occurred, the limiting coil acts as a superconducting reactor and the trigger coils quench at a critical current. Without the SFCL in the circuit, fault current after the load impedence is shorted might be increased to 1100A. The fault current is, therefore, successfully limited by the superconducting limiting coil to 100A determined by the coil inductance.

  • PDF

Design of an FPGA Based Controller for Delta Modulated Single-Phase Matrix Converters

  • Agarwal, Anshul;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.974-981
    • /
    • 2012
  • A FPGA based delta modulated single phase matrix converter has been developed that may be used in both cyclo-converters and cyclo-inverters. This converter is ideal for variable speed electrical drives, induction heating, fluorescent lighting, ballasts and high frequency power supplies. The peripheral input-output and FPGA interfacing have been developed through Xilinx 9.2i, to generate delta modulated trigger pulses for the converter. The controller has been relieved of the time consuming computational task of PWM signal generation by implementing the method of trigger pulse generation in a FPGA by using Hardware Description Language VHDL in Xilinx. The trigger circuit has been tested qualitatively by observing various waveforms on an oscilloscope. The operation of the proposed system has been found to be satisfactory.

A Study on Development of Oscillator Measurement Device Using Double Edge Time Interval Frequency Counter (더블 에지타임 인터벌 카운터를 이용한 발진기특정 장치개발에 관한 연구)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1386-1392
    • /
    • 2009
  • In this paper, we have developed the test equipment to measure performance of oscillator using Double Side Edge Trigger(DSET). This DSET increases counting number of micro pulse by frequency counter, which will successfully reduce the half measuring time to comparison with the existing counter by using DSET. This new concept of performance measuring equipment provides a high productivity and performance improvement.

Comparing of pre-trained Embedding for Event Extraction (사건 관계 추출을 위한 사전 학습 임베딩 비교)

  • Yang, Seung-Moo;Lee, Mira;Jeong, Chan-Hee;Jung, Hye-Dong
    • Annual Conference of KIPS
    • /
    • 2021.11a
    • /
    • pp.626-628
    • /
    • 2021
  • 사건 관계 추출 태스크는 구조화되지 않은 텍스트 데이터에서 사건의 구조화된 표현을 얻는 것이다. 하나의 문장에서도 많은 정보를 얻을 수 있는 중요한 태스크임에도 불구하고, 다양한 사전 학습 모델을 적용한 연구는 아직 활발하게 연구되지 않고 있다. 따라서 본 연구에서 사전 학습된 모델의 임베딩 기법 중 BERT, RoBERTa, SpanBERT에 각각 base, large 아키텍처를 적용하여 실험하였다. 사건을 식별하기 위한 trigger와 해당 trigger의 세부 argument를 식별하기 위한 분류기를 상위레이어로 각각 설계하였고, 다양한 배치 크기를 적용하여 실험하였다. 성능평가는 trigger/argument 각각 F1 score를 적용하였고, 결과는 RoBERTa large 모델에서 좋은 성능을 보인 것을 확인하였다.

Clinical investigation studies on 10 cases of patient with Bell' palsy using Trigger point treatment (Trigger point를 이용(利用)한 구안와사 환자(患者) 10례(例)에 대한 임상적(臨床的) 고찰(考察))

  • Jung, Young-don;Lee, Jun-gu;Kim, Young-il;Park, Tae-gyun;Shin, Young-il;Hwang, Jae-yeon;Lee, Hyen;Lee, Byung-ryul
    • Journal of Haehwa Medicine
    • /
    • v.10 no.2
    • /
    • pp.155-165
    • /
    • 2002
  • From July 1th 2001 to October 31th 2001, the Clinical investigation studies were carried out 10 cases of patient with Bell' palsy using Trigger point treatment group, who had been treated in Han-seung Oriental Medical Clinic. The results were like below: 1. The distribution of sex : Male were 4cases. female were 6case and the female to male ratio was 1.5 : 1. 2. The distribution of contributing factor : Unknown reason was most predominant 4 cases, and then were revealed to labor too hard. mental stress(3 cases), trauma common cold(1 case) in turn. 3. The distribution of perid to fall ill : Under a week was the most number 6cases, and then were revealed a week under two weeks(3 cases), over two weeks(1 case) in turn. 4. About period of treatment : The Trigger Point treatment group is shorter than the Acupuncture treatment group. 5. The distribution of grade on admission in descending order : Gr I was the most number and then GrII, GrIII in turn. 6. The distribution of clinical symptoms on admission : Mastoid pain was the most number 9 cases and then lacrimal gland disorder 8 cases, dysgeusia 4cases, hyperacusis 2 cases, the others 2 cases in turn. 7. About effect of treatment : The Trigger point treatment group is more excellent than the Acupuncture treatment group. 8. The more patient age is young, the more effect of treatment was excellent, had nothing to do with both groups. 9. The more perid to fall ill is short, the more effect of treatment was excellent. had nothing to do with both groups. 10. About period of improved frontal belly : The Trigger point treatment group is more excellent than the Acupuncture treatment group.

  • PDF

Design of an Automatic Target Sensing and Triggering System (적외선 감지 자동격발장치의 설계)

  • Hong S.H.;Kim K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1719-1723
    • /
    • 2005
  • An automatic target sensing and triggering system for small fire arms is proposed. The system consists of an optical collector, an infrared ray sensor responsive to human body temperature, an electric actuator and a trigger mechanism. TRIZ methodologies are used to develop solutions to several contradictory problems. Experimental results on the system performance is compared with predictions.

  • PDF

Development of a Broadband Self-recording Hydrophone

  • Kim, Bong-Chae
    • Ocean and Polar Research
    • /
    • v.28 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • A broadband self-recording hydrophone was developed to conveniently assemble a hydrophone array for use in receiving underwater sound waves. A trigger device with an electromagnetic induction coupler was also developed to control the hydrophone's operation. Main configurations and specifications of the self-recording hydrophone are introduced in this paper. We present experiment results conducted in a water tank to examine the operating behavior of the hydrophone. Some advantages are discussed when the self-recording hydrophones are used to make up a hydrophone array.