• 제목/요약/키워드: Transmitted Vibration

검색결과 405건 처리시간 0.027초

지하터널의 진동이 지표면에 미치는 영향 (Transmission of Ground Vibration Produced by Rail Vehicle : Tunnel Effect)

  • 김정태;이시우;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1095-1100
    • /
    • 2004
  • When the walls and floor of a tunnel are excited by a train, a ground vibration energy is transmitted to the surface and to footing of a nearby buildings. Excessive vibration affected to a building structures causes undesirable effect to the structural safety and the perception on residents in building. In this paper, a simple approach is introduced to predict how much vibration, in terms of level and spectra, is transmitted through the ground from the tunnel vibration excitation. A high rise building on a tunnel is selected as an application example of this case study.

  • PDF

진동시험용 치구의 실험적 구조변경 설계 (Experimental Structural Dynamic Modification of Fixture for Vibration Testing)

  • 정의봉;오영세;김준엽
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

고속프레스의 다이나믹 시스템 및 방진시스템 설계에 관한 연구 (A Study on the Design of Dynamic System and Vibration Isolation System in a High-speed Press)

  • 서진성;정철재;현기용;류민
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.856-865
    • /
    • 2015
  • In a high-speed press, numerous moving links are interconnected and each link executes a constrained motion at high speed. As a consequence, high-level dynamic unbalance force and unbalance moment are transmitted to the main frame of the press, which results in unwanted vibration and significantly degrades manufacturing accuracy. Dynamic unbalance force and unbalance moment inevitably transmits high-level vibrational force to the foundation on which the press is installed. Minimizing the vibrational force transmitted to the foundation is critical for the protection of both the operators and the surrounding structures. The whole task should be carried out in two steps. The first step is to reduce dynamic unbalance based upon kinematic and dynamic analyses. The second step is to design and build an optimal vibration isolation system minimizing the vibrational force transmitted to the foundation. Firstly, the dynamic design method is presented to reduce dynamic unbalance force and moment. For this a 3D CAD software was utilized and a computer program was written to compute dynamic unbalance force and moment. Secondly, the design method for vibration isolation system is presented. The method for designing coil springs and viscous dampers are explained in detail.

풍력발전기의 풍하중특성에 관한 연구 (A study on wind load characteristics of wind turbines)

  • 김정수;박노길;김영덕;김수엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.124-129
    • /
    • 2010
  • Wind load characteristics is investigated for vibration analysis of wind turbine gearbox. A normal wind model assumed, of which the wind velocity is increased according to the height from ground. A blast wind model is assumed, of which the maximum velocity is located at the center and the velocity profile is normally distributed. The periodical torque and bending moments transmitted to the main shaft of wind turbine are investigated. The average values and the harmonic terms of the transmitted moments are studied on the wind direction of range $-45^{\circ}{\sim}45^{\circ}$ and the bending moment characteristics are examined, which is regarded as the main source of the misalignment of gear train.

  • PDF

Experimental Investigation of the Effect of Lead Errors on Helical Gear and Bearing Vibration Transmission Characteristics

  • Park, Chan-Il;Lee, Jang-Moo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1395-1403
    • /
    • 2002
  • The characteristics of gear meshing vibration undesgo change as the vibration is transmitted from the gear to the housing. Therefore, vibration transmission characteristics of helical gear systems must be understood before the effective methods of reducing gear noise can be found. In this work, using a helical gear with different lead errors, the gear vibration in the rotational direction and the bearing vibration are measured. The frequency characteristics of gear and bearing vibration are investigated and a comparson is also provided.

MR Insert 의 충격저감 성능 연구 (A Study on MR Insert for Shock Wave Attenuation)

  • 강병우;김재환;최승복;김경수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.121-126
    • /
    • 2001
  • This paper presents the experimental study for the reduction of transmitted shock waves in smart structures incorporating MR insert. MR fluid is filled within the two aluminum layers and two piezoceramic disks are embedded on the host plate as a transmitter and a receiver of the shock wave. Pulse wave generated by the transmitter is transmitted to the receiver through the MR insert and the plate. By applying magnetic field to the MR insert, the amplitude of the transmitted shock wave is reduced remarkably. The attenuation performance is tested by changing the applied magnetic field on MR inserts in two ways: by changing angle of permanent rubber magnet from 90 to 5 with 5 decrements, by using electromagnet in which magnetic field is controllable. The propagating wave speed of MR insert is also investigated.

  • PDF

주거 공간내 공조기 소음의 전달 경로에 관한 연구 (A Study on the Sound Paths of Air-conditioner in House)

  • 최진권;손진희;장서일;이진교;김진섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.522-528
    • /
    • 2001
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were reflected on the simulated results.

  • PDF

음향 인클로저의 환기창을 통한 투과소음 능동제어 (Active Control of Noise Transmitted through a Window of Enclosures)

  • 지수민;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.670-672
    • /
    • 2014
  • In this study, we investigate active control of noise transmitted through a window of enclosures minimizing the acoustic power. To reduce noise of the enclosures, passive methods with absorbing material are generally used. The passive methods, however, are limited use due to the vantilation windows. In this case, these windows are path of noise leakage. Feedforward active noise control technology is applied to minimize the sound power from the enclosure. The feedforward controller is implemented with FIR filter based on the transfer functions calculated numerically. The controller reflects the delay due to FIR filter. The noise transmitted through the window is actively controlled, and the reduction of the power is obtained by 15dB.

  • PDF

경부선 철도 소음진동의 전파특성에 관한 기초 연구 (A Study on the Characteristics of Railroad Noise and Vibration Propagation in KYOUNGBU Line)

  • 김석홍;이성춘;김준호
    • 소음진동
    • /
    • 제3권1호
    • /
    • pp.47-55
    • /
    • 1993
  • In order to maintain comfortable life environment around railroad site, noise from train itself, and to train & rail interaction, and the vibration transmitted through the ground should be controlled to the extent of permissible level. In order to achieve this, the basic railroad noise & vibration data such as magnitude and frequency characteristics of them are necessary to establish the counterplan for railroad noise & vibration. In this study, we measured and analysed the characteristics of time variation, frequency, direction and distance attenuation of noise and vibration of the railroad between Seoul and Pusan.

  • PDF

공동주택 승강기 운행소음ㆍ진동 실태 및 저감설계 (Research on the Elevator-operating Noise and Vibration in Apartment Buildings)

  • 김명준;김하근;김흥식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.488-493
    • /
    • 2001
  • In accordance with the tendance to construct high-rise apartment buildings, the transporting elevators tend to speed up to 90-105m/min and to drive more frequently. So, the problem of noise produced by the elevator operation has been treated as an important subject. In this research, the actual conditions of noise and vibration which generated and transmitted by the elevator operation in apartment buildings were measured and analysed. And the several noise and vibration control design which helps reduce noise were examined.

  • PDF