• Title/Summary/Keyword: Transmission power coefficient

Search Result 147, Processing Time 0.021 seconds

Analysis of RF Inductive Couplers for Power Line Communication (전력선 통신의 RF 유도형 결합기 해석)

  • Noh, Young Seok;Lee, Gunbok;Park, Wee Sang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.85-91
    • /
    • 2015
  • We investigated the structure of inductive coupler and its magnetic coupling to increase the transmission coefficient for power line communication. A Rogowski coil, which is an air-cored inductive coupler, and a magnetic cored coupler were fabricated to analyze the transmission coefficient for different coupler parameters. This paper proposes the impedance matching method using lumped elements and an impedance transformer to increase the transmission coefficient. In the experiment, the transmission coefficient of the proposed system was increased in both narrowband and broadband cases, and a trade-off between the transmission coefficient and the bandwidth was shown. This method will be useful for the further study of impedance matching with the load variation.

Experimental Analysis of Power Transmission and Reflection In a Coupled Plate (연성평판에서의 파워투과 및 반사 특성 실험 해석)

  • Lee, Y.H.;Kil, H.G.;Lee, H.H.;Lee, K.H.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.170-173
    • /
    • 2005
  • The objective of this paper is to perform measurements of power transmission and reflection coefficients in a coupled plate. The coupled plate has been divided into 2 subsystems. The out-of-plane vibration has been only considered with assumption of relatively small in-plane vibration. The coupling loss factors have been measured with consideration of the power balance condition. The power transmission and reflection coefficients has been estimated from the measured values of the coupling loss factors. The measured power transmission and reflection coefficients have been compared with the corresponding theoretical coefficients in a semi-infinite coupled plate.

  • PDF

Vibration Power Flow Analysis of Coupled Shell Structures (연성된 쉘 구조물의 진동 파워흐름해석)

  • Kim, Il-Hwan;Hong, Suk-Yoon;Park, Do-Hyun;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.352.2-352
    • /
    • 2002
  • In this paper, Power Flow Analysis (PFA) method has been applied to the prediction of vibration energy density and intensity of coupled shell structures in the medium-to-high frequency ranges. To consider the wave transformation at joint between shell elements, power transmission and reflection coefficients are investigated for various joint angles, and here Donnell-Mushtari thin shell theory has been used. (omitted)

  • PDF

Vibration Power Flow Analysis of Coupled Co-planar Orthotropic Plates (동일 평면상에서 연성된 직교이방성 평판의 진동파워흐름해석)

  • Song, Jee-Hun;Park, Do-Hyun;Hong, Suk-Yoon;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.856-862
    • /
    • 2010
  • In this paper, the power flow analysis(PFA) method was developed to predict the vibrational responses of coupled co-planar orthotropic plates in frequencies ranging from medium to high. To cover the power transmission and reflection at the joint of the orthotropic plates, the wave transmission approach is applied with the assumption that all the incident waves are normal to the joint. Through numerical analyses, the power flow energy density and intensity fields of coupled co-planar orthotropic plates were compared with those of classical modal solutions by changing the frequency and internal loss factor, and they show good agreement in terms of the global decay and the attenuation patterns of the energy density.

Effect Analysis of Spacer Stiffness and Interval on Galloping of Power Transmission Lines (스페이서 강성과 간격이 송전선 갤러핑에 미치는 영향분석)

  • Oh, Yun-Ji;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Due to icing and snow, power transmission lines have asymmetric cross sections, and their motion becomes unstable. At this time, the vibration caused by the wind is called galloping. If galloping is continuous, short circuits or ground faults may occur. It is possible to prevent galloping by installing spacers between transmission lines. In this study, the transmission line is modeled as a mass-spring-damper system by using RecurDyn. To analyze the dynamic behavior of the transmission line, the damping coefficient is derived from the free vibration test of the transmission line and Rayleigh damping theory. The drag and lift coefficient for modeling the wind load are calculated from the flow analysis by using ANSYS Fluent. Galloping simulations according to spacer stiffness and interval are carried out. It is found that when the stiffness is 100 N/m and the interval around the support is dense, the galloping phenomenon is reduced the most.

Extraction Solution for the Coupling Coefficient at the Magnetically Coupled Wireless Power Transmission (자계 결합 무선 전력 전송에서의 결합 계수 추출 방법)

  • Kim, Gun-Young;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1073-1078
    • /
    • 2012
  • This paper presented the extraction solution for the coupling coefficient at the magnetically coupled wireless power transmission(WPT) system through the analysis of its equivalent circuit considering the loss. The conventional extraction solution using coupled mode theory is generalized employing the extracted solution considering the load resistance. Consequently, the measuring process of extracting coupling coefficient becomes convenient since the even/odd mode analysis is not necessary. Furthermore, the coupling coefficient obtained from the induced extraction method was in excellent agreement with the coupling coefficient obtained using the ratio of magnetic flux passing through the two loops. The extraction of the accurate coupling coefficient at the magnetically coupled WPT is an essential work to analyze and optimize the WPT system.

One-dimensional Waveguides Shape Design far Transmission Power Coefficient Maximization (전달 일률 계수 최대화를 위한 1차원 도파관 형상 설계)

  • Lee, Il-Kyu;Lee, Joong-Seok;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.481-482
    • /
    • 2008
  • This investigation presents a method to design an optimal shape of a matching waveguide connecting two waveguides having different impedances. The design objective is to maximize power transmission through the waveguide system. When an incident wave impinges on an elastic waveguide system consisting of waveguides of different impedances, all of the incident wave power may not pass through due to the mechanical impedance. Therefore, the maximization of the transmitted power through a waveguide difficult to achieve without a systematic design method. In this work, the optimal shape design of a matching waveguide connecting two waveguides of different impedances is formulated as a shape optimization problem. If the material of the matching waveguide is given, its shape is the only parameter controlling the transmission power. Relatively simple one dimensional elastic wave transmission problems will be considered in this work, but the underlying methodology and the related physics can be clearly demonstrated. The influences of initial configurations as well as the target frequencies on the optimized shapes will be also investigated.

  • PDF

Dust collector strainer and carbon filter pressure permeation analysis (흡연집진기 내 스트레이너 및 카본필터 압력투과 해석)

  • Lee, Chi-Woo
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 2015
  • Dust collector is one of the most widely used equipment among the method of separating particles, it filters exhaust gas having various kinds of dusts through several filters installed on parallel. This research investigated the moving characteristic of Honeycomb-type carbon filter in pressure drop of smoking collector's ventilation system. It also compared pressure transmission coefficient through pressure drop according to flow velocity change.

The Compensation Characteristics of WDM Channel Distortion Dependence on NRZ format and RZ Format (NRZ 형식과 RZ 형식에 따른 WDM채널 왜곡의 보상 특성)

  • 이성렬;조성언
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1184-1190
    • /
    • 2003
  • In this paper, we investigated the characteristics of compensation for distorted NRZ signal and RZ signal in 320 Gbps WDM system as a function of channel input power, fiber dispersion coefficient and transmission length, respectively. The considered WDM transmission system is based on mid-span spectral inversion(MSSI) compensation method having highly nonlinear dispersion shifted fiber(HNL-DSF) optical phase conjugator(OPC) in the mid-way of total transmission line. We confirmed that the signal input power range compensated by MSSI is broadened by using RZ as a signal format in WDM system with small fiber dispersion coefficient, The range of fiber dispersion coefficient compensating overall distorted WDM channels is limited, because degree of compensation for distorted channel with low conjugated-wave power becomes gradually degrade as fiber dispersion coefficient becomes gradually higher. It is showed that RZ format and NRZ format is suited for long-haul transmission in WDM system with small fiber dispersion coefficient and with large fiber dispersion coefficient, respectively.

Design of Long Span Overhead Transmission Line using Special High-tension Wire (특수 고장력전선을 사용한 장경간 가공송전선로 설계)

  • Na, Sang-Yong;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.183-187
    • /
    • 2016
  • Recently, power demand has been increasing every year according to variation of electrical equipments and temperature rise in summer season. So, much more overhead line is being demanded to copy with increasing power demand and operate reliable power system. This paper analysis the characteristics of long span overhead transmission line using special high-tension wire in such as a safety factor, coefficient of elasticity, and the coefficient of linear expansion. Based on the analysis, we proposed the effectiveness of special high-tension wire having much more advantages with respect to height of steel tower and dip compared with conventional ACSR in long span overhead transmission line.