• 제목/요약/키워드: Transmission line method

검색결과 1,065건 처리시간 0.032초

Stability behavior of the transmission line system under incremental dynamic wind load

  • Sarmasti, Hadi;Abedi, Karim;Chenaghlou, Mohammad Reza
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.509-522
    • /
    • 2020
  • Wind load is the principal cause for a large number of the collapse of transmission lines around the world. The transmission line is traditionally designed for wind load according to a linear equivalent method, in which dynamic effects of wind are not appropriately included. Therefore, in the present study, incremental dynamic analysis is utilized to investigate the stability behavior of a 400 kV transmission line under wind load. In that case, the effects of vibration of cables and aerodynamic damping of cables were considered on the stability behavior of the transmission line. Superposition of the harmonic waves method was used to calculate the wind load. The corresponding wind speed to the beginning of the transmission line collapse was determined by incremental dynamic analysis. Also, the effect of the yawed wind was studied to determine the critical attack angle by the incremental dynamic method. The results show the collapse mechanisms of the transmission line and the maximum supportable wind speed, which is predicted 6m/s less than the design wind speed of the studied transmission line. Based on the numerical modeling results, a retrofitting method has been proposed to prevent failure of the tower members under design wind speed.

한국전력 노후 가공송전선의 동적송전용량에 대한 재평가 (A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

송전선로 직선슬리브 원격점검 방법 및 장치 (Development of a Remote Inspection Method and Device for Line Sleeves on Transmission Line)

  • 이재경;정남준;김호기;김경호
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.206-213
    • /
    • 2011
  • Line sleeves, which used to connect ACSR cables when transmission lines were constructing, sometimes cause power transmission failure due to deterioration and corrosion. Therefore, power transmission line should be inspected regularly to prevent national disaster. Current inspection tool detects insertion length of transmission line on line sleeves, the inspection tool includes enormous error by operator. Moreover, the system is not controlled remotely, negligent accident would be caused while inspecting. To deal with those problems, KEPCO reviewed several ways to inspect line sleeves and proposes new method to inspect line sleeve by measuring magnetic flex which penetrate junction of steel and aluminum sleeve. The developed inspection tool is reliable enough to detect eccentric sleeves. Also, the developed inspection device was applied on actual transmission line and verified its effectiveness.

신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법 (Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy)

  • 백자현;김현진;최순호;박상호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

송전 선로의 사고 거리에 따른 특성 주파수 해석 (Analysis of Characteristic Frequency along Fault Distance on a Transmission Line)

  • 남순열;홍정기;강상희;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.

전력전송구간을 분할하여 데이터 신호를 전송하는 전력선 통신방법 (Power Line Communication Method with Splitting of Power Transmission Interval)

  • 조재승;황일규
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.252-258
    • /
    • 2012
  • This paper studies the power line communication method with splitting of power transmission interval in the small DC power system using pulse width modulation. The method divides the entire interval for transmitting power and data into a power transmission interval where power is supplied to a load and a data transmission interval where power from the power supply to the load is disconnected. The circuit is designed for the implementation to separate the power line from the power supply and load. The results of tests show the feasibility of the proposed power line communication method.

전기철도에서 급전선로의 line impedance 계산에 관한 연구 (A study on the Line impedance calculation method in electrified railway system)

  • 이춘배;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1308-1312
    • /
    • 2004
  • Transmission line impedance calculation has been tried for obtaining exact value. The method proposed by Carson contains indefinite complex integral. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. In this paper, we proposed a simplified Carson solution by analytical method using ground transmission line return current. This method calculate the transmission line impedance easily.

  • PDF

TLM 및 CTLM을 이용한 실리콘 태양전지 전면전극소재의 접촉 비저항 측정 비교연구 (Comparison of Contact Resistivity Measurements of Silver Paste for a Silicon Solar Cell Using TLM and CTLM)

  • 신동윤;김유리
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.539-545
    • /
    • 2014
  • 실리콘 태양전지의 실버 전극과 이미터층 사이의 접촉 비저항은 원형 접촉 비저항 측정법과 선형 비저항 측정법을 이용하여 계측되어 왔다. 원형 접촉 비저항 측정법은 누설 전류를 차단하기 위한 메사 에칭 등의 부가적인 공정이 요구되지 않는 장점이 있으며, 선형 접촉 비저항 측정법은 완성된 태양전지로부터 직접 샘플을 취득하여 측정을 수행할 수 있다는 장점이 있다. 본 연구에서는 이 두 가지 측정법들을 이용하여 실리콘 태양전지 전면 전극의 접촉 비저항을 계산하기 위한 저항값들을 측정할 때 수반되는 문제점들에 대한 비교연구를 수행하였으며, 선형 접촉 비저항 측정법이 실버 전극의 선폭과 두께에 따른 접촉 비저항 변화를 좀더 정확하게 묘사할 수 있는 요인에 대해 설명하였다.

기판적층형 가유전체 전송선로의 특성 임피던스 계산 방법 (A Method for Calculating the Characteristic Impedance of Substrate Integrated Artificial Dielectric Transmission Lines)

  • 임종식;구자경;한상민;정용채;안달
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1585-1591
    • /
    • 2009
  • This paper describes a new method for extracting characteristic impedance of transmission line using Substrate Integrated Artificial Dielectric (SIAD). The new procedure to calculate the characteristic impedance of SIAD transmission line is described with the proper equations and basic transmission line theory. The characteristic impedance is determined as an almost fixed value in the proposed method, while it fluctuates according to frequency in the previous method. As the result, the effective dielectric constant of SIAD transmission line is calculated as a fixed value rather than fluctuating one. In order to show the validity of the proposed method, SIAD microstrip lines are simulated and measured, and characteristic impedances and effective dielectric constant are calculated and compared to the previous method.

FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선 (Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line)

  • 임정욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권12호
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.