Browse > Article

Analysis of Characteristic Frequency along Fault Distance on a Transmission Line  

남순열 (효성중공업 연구소)
홍정기 (효성중공업 연구)
강상희 (명지대학교 전기공학과/차세대 전력기술 연구센)
박종근 (서울대학교 전기공학부)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers A / v.53, no.8, 2004 , pp. 432-437 More about this Journal
Abstract
Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.
Keywords
Characteristic Frequency; EMTP; Line Fault; Long Transmission Line; Low-pass Filter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. C. Gu, and S. L. Yu, 'Removal of DC-offset in current and voltage signals using a novel Fourier filter algorithm,' IEEE Trans. Power Delivery, vol. 15, No. 1, January 2000, pp. 73-79   DOI   ScienceOn
2 S. R. Nam, S. H. Kang, and J. K. Park, 'An Analytic Method for Measuring Accurate Fundamental Frequency Components,' IEEE Trans. Power Delivery, Vol. 17, April 2002, pp. 405-411   DOI   ScienceOn
3 J. F. Hauer, C. J. Demeure, and L. L. Scharf, 'Initial results in Prony analysis of power system response signals,' IEEE Trans Power Systems, Vol. 5, No. 1, February 1990, pp. 80-89   DOI   ScienceOn
4 Y. Tang, H. Chen, H. Wang, and F. Dai, 'Transmission line models used in travelling wave studies,' Transmission and Distribution Conference, Vol. 2, 1999, pp. 797-803   DOI
5 R. Benato, R. Caldon, A. Paolucci, R. Turri, 'Resonance phenomena on line-to-ground fault current harmonics in MV networks,' 8th International Conference on Harmonics and Quality of Power, Vol. 1, October 1998, pp. 359-364   DOI
6 L. M. Popovic, 'General equations of the line represented by discrete parameters. II. Resonant phenomena,' IEEE Trans. Power Delivery, vol. 6, No. 1, January 1991, pp. 302-308   DOI   ScienceOn
7 A.G. Phadke, and J.S. Thorp, Computer Relaying for Power Systems, Research Studies Press Ltd. 1988