• Title/Summary/Keyword: Transmission line analysis

Search Result 901, Processing Time 0.035 seconds

Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables (지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용)

  • Choi, Jong-Kee;Jang, Byung-Tae;An, Yong-Ho;Choi, Sang-Kyu;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.

Spectral element method in the analysis of vibrations of overhead transmission line in damping environment

  • Dutkiewicz, Maciej;Machado, Marcela
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.291-303
    • /
    • 2019
  • In the paper the analysis of natural vibrations of the transmission line with use of spectral elements and the laboratory experiments is performed. The purpose of the investigation is to analyze the natural vibrations of the transmission line and compare with the results obtained in the numerical simulations. Particular attention is paid to the hysteretic and aerodynamic damping analysis. Sensitivity of the wave number is performed for changing of the tension force, as well as for the different damping parameters. The numerical model is made using the Spectral Element Method. In the spectral model, for various parameters of stiffness, damping and tension force, the system response is checked and compared with the results of the accelerations obtained in the measurements. A frequency response functions (FRF) are calculated. The credibility of the model is assessed through a validation process carried out by comparing graphical plots of FRF and time history analysis and numerical values expressing differences in acceleration amplitude (MSG), phase angle differences (PSG) and differences in acceleration and phase angle total (CSG) values. The next aspect constituting the purpose of this paper is to present the wide possibilities of modelling and simulation of slender conductors using the Spectral Element Method. The obtained results show good accuracy in the range of both experimental measurements as well as simulation analysis. The paper emphasizes the ease with which the sensitivity of the conductor and its response to changes in density of spectral mesh division, tensile strength or material damping can be studied.

A Study on the Analysis of Galloping for Power transmission line (송전선의 전선도약 해석에 관한 연구)

  • 김환성;변기식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1051-1057
    • /
    • 2001
  • In this paper, we deal with three types of modelling method for the analysis of galloping in power transmission line (PTL). The single mass model is obtained under linearization method and it is applied into f-order model. On these models, the nature frequencies of PTL are obtained and it makes an effects on the galloping directly. In simulation, we verify that the maximum magnitude of nature frequency depends on the galloping distance of PTL. Also from the analysis of frequency response, a few of reduction method for galloping are introduced which is effected by distance of PTL, wind velocity and icing types.

  • PDF

Transmission Line Analysis of Accumulation Layer in IEGT

  • Moon, Jin-Woo;Chung, Sang-Koo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.824-828
    • /
    • 2011
  • Transmission line analysis of the surface a cumulation layer in injection-enhanced gate transistor (IEGT) is presented for the first time, based on per-unit-length resistance and conductance of the surface layer beneath the gate of IEGT. Lateral electric field on the accumulation layer surface, as well as the electron current injected into the accumulation layer, is governed by the well-known wave equation, and decreases as an exponential function of the lateral distance from the cathode. Unit-length resistance and conductance of the layer are expressed in terms of the device parameters and the applied gate voltage. Results obtained from the experiments are consistent with the numerical simulations.

Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable (혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의)

  • Jung, Che-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF

Joint stress based deflection limits for transmission line towers

  • Gayathri, B.;Ramalingam, Raghavan
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2018
  • Experimental investigations have revealed significant mismatches between analytical estimates and experimentally measured deflections of transmission towers. These are attributed to bolt slip and joint flexibility. This study focuses on effects of joint flexibility on tower deflections and proposes criterions for permissible deflection limits based on the stresses in joints. The objective has been framed given that guidelines are not available in the codes of practices for transmission towers with regard to the permissible limits of deflection. The analysis procedure is geometric and material nonlinear with consideration of joint flexibility in the form of extension or contraction of the cover plates. The deflections due to bolt slip are included in the study by scaling up the deflections obtained from analysis by a factor. Using the results of the analysis, deflection limits for the towers are proposed by limiting the stresses in the joints. The obtained limits are then applied to a new full scale tower to demonstrate the application of the current study.

Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media (다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석)

  • Kim, Yoon-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.61-67
    • /
    • 2010
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain (FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

Variable Time Step Simulation and Analysis of Hydraulic Control Systems using Transmission Line Modeling (전달관로 모델링을 이용한 유압제어 시스템의 가변 시간스텝 시뮬레이션 및 해석)

  • Hwang, Un-Gyu;Jo, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.843-850
    • /
    • 2002
  • This paper presents a simulation method using the transmission line modeling to reduce simulation runtime of hydraulic control systems. This method is based on separating the system components each other using the transmission line elements prior to simulation, which leads to divide the simulated system into several subsystems suitable for an even more efficient integration. It can also handle nonlinearities and discontinuities without flag signal when restarting integration. By applying variable integration timestep to parallel hydraulic circuits via parallel processing, it is shown that simulation run-time can be reduced significantly compared with that of Runge Kutta method.

Analysis of Inductive Interference from EHV Transmission to buried Gas Pipelines (초고압 송전선로에서 가스관에 미치는 유도 장해 해석)

  • Lee, Seung-Youn;Ko, Eun-Young;Yun, Suk-Moo;Park, Nam-Ok;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.458-460
    • /
    • 2000
  • In this paper, we analyze the inductive coupling between overhead power transmission lines and neighbouring gas pipelines or other conductors, when they parallel to a line section in a phase-to-earth fault is assumed on the transmission line. A numerical procedure employing the finite-element method(FEM) is used in conjunction with Faraday's law, in order to predict the current in a faulted transmission line as well as the induced voltages across points on a pipeline running parallel to the faulted line and remote earth. The results lead to conclusion that may be useful to power system engineers.

  • PDF

Analysis of Magnetic Field on Ultra High Voltage ac Transmission Line (초고압 송전선로의 자계해석에 관한 연구)

  • Lee, Joo-Youl;Ko, Eun-Young;Jung, Ho-Sung;Shin, Myung-Chul;Kweon, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1382-1384
    • /
    • 1999
  • Traditional magnetic field computation techniques assume that the current carrying power line conductors are straight horizontal wires. This assumption result in much errors. So this paper considerd catenary curve for the dip of real transmission line. We have data from various position at transmission line, on the earth. And as far from transmission condutor a eddy current affect of the position are con siderd.

  • PDF