• 제목/요약/키워드: Transmission control

Search Result 4,097, Processing Time 0.037 seconds

Feedback Shift Controller Design of Automatic Transmission for Tractors (트랙터 자동변속기 되먹임 변속 제어기 설계)

  • Jung, Gyu Hong;Jung, Chang Do;Park, Se Ha
    • Journal of Drive and Control
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Nowadays automatic transmission equipped vehicles prevail in construction and agricultural equipment due to their convenience in driving and operation. Though domestic vehicle manufacturers install imported electronic controlled transmissions at present, overseas products will be replaced by domestic ones in the near future owing to development efforts over the past 10 years. For passenger cars, there are many kinds of shift control algorithms that enhance the shift quality such as feedback and learning control. However, since shift control technologies for heavy duty vehicles are not highly developed, it is possible to improve the shift quality with an organized control method. A feedback control algorithm for neutral-into-gear shift, which is enabled during the inertia phase for the master clutch slip speed to track the slip speed reference, is proposed based on the power transmission structure of TH100. The performance of the feedback shift control is verified by a vehicle test which is implemented with firmware embedded TCU. As the master clutch engages along the predetermined speed trajectory, it can be concluded that the shift quality can be managed by a shift time control parameter. By extending the proposed feedback algorithm for neutral-into-gear shift to gear change and shuttle shift, it is expected that the quality of the shift can be improved.

The Algorithm on Channel Converting and Monitoring of the Remote Controlled Transceiver (원격제어 송수신기의 채널변환 및 모니터링에 대한 알고리즘)

  • 조학현;최조천;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.266-271
    • /
    • 1999
  • The purpose in this study has to development the system on increasing operation of old-typed transceiver for solve the question that limited allocation frequencies and continuesly icreasment of traffic. Therefore, we are desigened the remote control system that has the function for variable channels, PTT and monitoring of transmission power and frequencies. Exchange of control data is to hold in common the twist two-wire or telephone line for the voice transmission. The H/W is consist of FSK and MCS-51 processor which are up-down control of channel, n control and monitoring display by serial data transmission. According to the simplex traffic operation is designed the algorithm of serial data transmission by sequential transmission sequence and protocol. The S/W of sequential transmission sequence is designed to usefully the intergrated communications system which is able to connection between the multi-transceiver and multi-terminal by master processor.

  • PDF

Design of Wireless Power Transmission Antennas for Railway High-Speed Transponder System (철도교통용 고속 트랜스폰더 시스템 무선전력전송 안테나 설계)

  • Lee, Jae-Ho;Park, Sungsoo;Kim, Seong Jin;Ahn, IL Yeup
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.602-611
    • /
    • 2017
  • In railway systems, the exchange of information between running trains and wayside equipment is a very important role in various applications such as position detection and train control. Track circuits have been used as the medium for information transmission between trains and wayside. However, track circuits must be installed continuously along the track on the ground, resulting in an inevitable increase in installation and maintenance costs. One of the most promising solutions to reduce these costs is to mix continuous information transmission (via wireless communication) and discontinuous information transmission (via transponder). In this study, we designed antennas of railway high-speed transponder readers and tags for wireless power transmission, which can be used to transmit information from ground to high-speed trains with a maximum speed of 400km/h. We also verified system performance through computational simulation and prototyping.

A Locally Acquired Falciparum Malaria via Nosocomial Transmission in Korea

  • Kim, Jung-Yeon;Kim, Jeong-Su;Park, Mi-Hyun;Kang, Young-A;Kwon, Jun-Wook;Cho, Shin-Hyeong;Lee, Byeong-Chul;Kim, Tong-Soo;Lee, Jong-Koo
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.3
    • /
    • pp.269-273
    • /
    • 2009
  • A 57-year old man who was admitted to an emergency room of a tertiary hospital with hemoptysis developed malarial fever 19 days later and then died from severe falciparum malaria 2 days later. He had not traveled outside of Korea for over 30 years. Through intensive interviews and epidemiological surveys, we found that a foreign patient with a recent history of travel to Africa was transferred to the same hospital with severe falciparum malaria. We confirmed through molecular genotyping of the MSP-1 gene that Plasmodium falciparum genotypes of the 2 patients were identical. It is suggested that a breach of standard infection control precautions resulted in this P. falciparum transmission between 2 patients in a hospital environment. This is the first report of a nosocomial transmission of falciparum malaria in Korea.

Energy-Conserving MAC Protocol in Ubiquitous Sensor Networks (유비쿼터스 센서 망에서의 에너지 절약형 매체접근 제어 프로토콜)

  • Yang, Hyun-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.1
    • /
    • pp.177-185
    • /
    • 2008
  • Research on media access control (MAC) scheme for Wireless Sensor Network (WSN) has been mainly focused on energy efficiency improvement, while interest on latency is relatively weak. However, end-to-end latency could be a critical limitation specifically in the multi-hop network such as wireless multimedia sensor networks. In this paper we propose a media access control scheme with distributed transmission power control to Improve end-to-end transmission latency as well as reduce power consumption in multi-hop wireless sensor networks. According to the simulation results, the proposed scheme is turned out to be an energy efficient scheme with improved end-to-end transmission latency.

Development of the Oil Consumption Rate Test Method and Measurement Data Analysis for an Automatic Transmission System (자동변속기 오일 소요유량 시험법개발 및 측정데이터 분석)

  • Jeong, H.S.;Oh, S.H.;Yi, J.S.;Lim, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2009
  • Automatic power transmission systems consisted of a torque converter and several planetary gear sets, clutches and brakes are controlled by a hydraulic shift control circuit and an electronic transmission control unit. The hydraulic circuit serves for the operation of the torque converter and lubrication oil supply of the transmission system as well as for the actuation of clutches for the automatic gear shift. The complicated hydraulic control circuit constructed by many spools, solenoids, orifices and flow passages are integrated into one small valve block and it is powered by one hydraulic pump. In this paper, a test equipment was developed to measure the oil consumption of each component at various wide operating conditions. Test data about 730 sets acquired from five test items are analyzed and discussed on the oil capacity of the circuit.

  • PDF

Power Transmission from a Vibrating Mass to a Supporting Elate through Isolators (능동 및 수동격리기를 적용한 진동계에 있어서 힘의 전달에 관한 연구)

  • Jin-Woo Lee;Colin H. Hansen
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.200-207
    • /
    • 2001
  • The transmission of harmonic vibratory power form a vibrating rigid body into a supporting plate through passive and active isolators is investigated theoretically and experimentally. The theoretical model allows for the transmission of vertical and horizontal harmonic forces and moments about all three coordinate sun. The experiment is to use vibration actuators attached to the intermediate mass of the two-stage mount to minimize the rotational and translational vibration of the intermediate mass. The performance is done by measuring the vibration at the error sensors due to the primary vibration source and measuring the transfer functions from the control sources to the error sensors. Results show that over a frequence range from 1 to 100Hz, transmission into the supporting plate can be reduced substantially by employing in parallel with existing passive isolators, active isolators adjusted to provide appropriate control force amplitudes.

  • PDF

Temperature effect on seismic behavior of transmission tower-line system equipped with SMA-TMD

  • Tian, Li;Liu, Juncai;Qiu, Canxing;Rong, Kunjie
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • Transmission tower-line system is one of most critical lifeline systems to cities. However, it is found that the transmission tower-line system is prone to be damaged by earthquakes in past decades. To mitigate seismic demands, this study introduces a tuned-mass damper (TMD) using superelastic shape memory alloy (SMA) spring for the system. In addition, considering the dynamic characteristics of both tower-line system and SMA are affected by temperature change. Particular attention is paid on the effect of temperature variation on seismic behavior. In doing so, the SMA-TMD is installed into the system, and its properties are optimized through parametric analyses. The considered temperature range is from -40 to $40^{\circ}C$. The seismic control effect of using SMA-TMD is investigated under the considered temperatures. Interested seismic performance indices include peak displacement and peak acceleration at the tower top and the height-wise deformation. Parametric analyses on seismic intensity and frequency ratio were carried out as well. This study indicates that the nonlinear behavior of SMA-TMD is critical to the control effect, and proper tuning before application is advisable. Seismic demand mitigation is always achieved in this wide temperature range, and the control effect is increased at high temperatures.

Design of a Remote Lighting Control System Using Time Division Multiplex Transmission (시분할 다중 전송방식을 이용한 원격 조명제어 설계)

  • 정성재;김일환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.33-33
    • /
    • 2000
  • In this paper a new distributive control system for BA(Building Automation ) lighting control used on general microprocessors is presented. For optimal lighting control and saving energy, The system have to control the group and pattern lighting control as well as individual light control at one time. Tn this paper, This functions are accomplished with low-cost and simple microprocessor. A plurality of modulated light control terminals are connected to the central control unit through a pair of power line. This power line provide both power and signal to the each terminal and the data is transmitted through cyclic time division multiplex transmission. With this structure a low-cost distributive control system for lighting applications has been achieved, allowing energy and maintenance saving and reliability increase of the light control system.

  • PDF

Preventing the Transmission of Tuberculosis in Health Care Settings: Administrative Control

  • Jo, Kyung-Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • It is well established that health care workers (HCWs) have a considerably higher risk of occupationally acquired tuberculosis (TB). To reduce the transmission of TB to HCWs and patients, TB infection control programs should be implemented in health care settings. The first and most important level of all protection and control programs is administrative control. Its goals are to prevent HCWs, other staff, and patients from being exposed to TB, and to reduce the transmission of infection by ensuring rapid diagnosis and treatment of affected individuals. Administrative control measures recommended by the United States Centers for Disease Control and Prevention and the World Health Organization include prompt identification of people with TB symptoms, isolation of infectious patients, control of the spread of the pathogen, and minimization of time spent in health care facilities. Another key component of measures undertaken is the baseline and serial screening for latent TB infection in HCWs who are at risk of exposure to TB. Although the interferon-gamma release assay has some advantages over the tuberculin skin test, the former has serious limitations, mostly due to its high conversion rate.