• Title/Summary/Keyword: Transmission characteristic

Search Result 997, Processing Time 0.026 seconds

The circuit design to be power transmission or power distribution using the dual characteristic impedance transmission line (이중 특성 임피던스 전송 선로를 이용한 전력 전송 또는 전력 분배가 가능한 회로 설계)

  • Park, Unghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2339-2344
    • /
    • 2014
  • of a microstrip transmission line, this transmission line can operate as the microstrip line or the coplanar line according to open or short connection between the ungrounded copper plane and grounded plane on the base plane. Two different type operation of the transmission line means that one transmission line can have two different characteristic impedances. This paper proposes and fabricates the circuit to be operated 2-ports power transmission line or 2-way power divider with the stable input matching characteristic by using this dual-impedance transmission line. The proposed circuit operates 2-ports power transmission line in case of the coplanar line or 2-way power divider line in case of the microstrip line. The fabricated circuit shows $S_{21}$ > -0.2 dB and $S_{11}$ < -15 dB above 700 MHz when the circuit operates 2-ports power transmission line. And, it is $S_{21}$ > -3.8 dB, $S_{11}$ < -10 dB and $S_{21}/S_{31}$ < ${\pm}0.3dB$ above 700 MHz when the circuit operates 2-way power divider.

Seismic response and failure analyses of pile-supported transmission towers on layered ground

  • Pan, Haiyang;Li, Chao;Tian, Li
    • Structural Engineering and Mechanics
    • /
    • v.76 no.2
    • /
    • pp.223-237
    • /
    • 2020
  • Transmission towers have come to represent one of the most important infrastructures in today's society, which may suffer severe earthquakes during their service lives. However, in the conventional seismic analyses of transmission towers, the towers are normally assumed to be fixed on the ground without considering the effect of soil-structure interaction (SSI) on the pile-supported transmission tower. This assumption may lead to inaccurate seismic performance estimations of transmission towers. In the present study, the seismic response and failure analyses of pile-supported transmission towers considering SSI are comprehensively performed based on the finite element method. Specifically, two detailed finite element (FE) models of the employed pile-supported transmission tower with and without consideration of SSI effects are established in ABAQUS analysis platform, in which SSI is simulated by the classical p-y approach. A simulation method is developed to stochastically synthesize the earthquake ground motions at different soil depths (i.e. depth-varying ground motions, DVGMs). The impacts of SSI on the dynamic characteristic, seismic response and failure modes are investigated and discussed by using the generated FE models and ground motions. Numerical results show that the vibration mode shapes of the pile-supported transmission towers with and without SSI are basically same; however, SSI can significantly affect the dynamic characteristic by altering the vibration frequencies of different modes. Neglecting the SSI and the variability of earthquake motions at different depths may cause an underestimate and overestimate on the seismic responses, respectively. Moreover, the seismic failure mode of pile-supported transmission towers is also significantly impacted by the SSI and DVGMs.

Influence of Internal Partition of Simple Extension Chamber on the Acoustic Transmission Loss (단순 확장 관 내부 파티션이 음향 투과손실에 미치는 영향해석)

  • Park, Jeong-Pil;Jeong, Weui-Bong;Ahn, Se-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.690-692
    • /
    • 2014
  • To identify characterization of a simple extension chamber that have the two internal partition, produce the curve to estimate the transmission loss without the computer analysis. For helpful for internal optimum design, identify the characteristic of internal partition on transmission loss. Made estimated transmission loss curve by function of relationship of internal partition and transmission. Check the similarity of predicted transmission loss and analysis transmission loss. Usage of the predicted transmission loss made by relationship of internal partition and transmission loss is good information to place the internal partition so as to maximize the transmission loss on target frequency at optimal design on muffler.

  • PDF

Unequal Bagley Divider based on Uniform Characteristic Impedance Transmission Lines with Adjustment Electrical Lengths (균일한 임피던스 전송선로 길이 조정을 통한 비대칭 Bagley 분배기)

  • Yoon, Young-Chul;Hong, Soung-Wook;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.287-293
    • /
    • 2017
  • This paper describes an unequal Bagley divider using uniform transmission lines with adjustment electrical lengths between output ports. To obtain an arbitrary dividing ratio of Bagley divider, we have only adjusted the electrical lengths of the transmission line between output ports. All the transmission lines have the same characteristic impedance value. This design method does not require an impedance transformer for port matching. For verification, we simulated and fabricated a 3-way, 1:2:1 and 5-way, 2:3:4:3:2 ratio Bagley divider with an operating frequency of 2 GHz. The experimental results are in agreement with the simulated results.

Power Divider using Zero-Degree Composite Right/Left-Handed Transmission Line (0도 CRLH 전송선로를 이용한 전력 분배기)

  • Kim, Seung-Hwan;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.5
    • /
    • pp.720-725
    • /
    • 2009
  • This paper proposes a modified Wilkinson power divider using a zero-degree composit right/left-handed(CRLH) transmission line to obtain a isolation between ports. A zero-degree CRLH transmission line, which has a total electrical length of zero, consists of a RH(Right-Handed) transmission line of a negative phase characteristic and a LH (Left-Handed) transmission line of a positive phase characteristic. To validate a value of zero-degree CRLH transmission line, the electrical lengths of RH and LH transmission line select $-30^{\circ}$ and $+30^{\circ}$ and a 2-way Wilkinson divider designed, we are measured S21 of -3.3dB, S11 of -27.5dB and S23 of -25dB at 1GHz center frequency. These characteristics are same the conventional divider using RH transmission line.

  • PDF

A Study on Basic Characteristics of Short Wavelength Transmission Line Employing Periodically Arrayed Capacitive Devices and Its Application to Highly Miniaturized Passive Components on MMIC (주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로의 기본특성 연구와 MMIC용 초소형 수동소자개발에의 응용)

  • Jang, Eui-Hoon;Jeong, Jang-Hyeon;Choi, Tae-Il;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.157-165
    • /
    • 2012
  • In this study, a short-wavelength transmission line employing periodically arrayed capacitive devices (PACD) was studied for application to miniaturized on-chip passive component on monolithic microwave integrated circuit (MMIC). The transmission line employing PACD showed shorter wavelength and lower characteristic impedance than conventional microstrip transmission line. The wavelength transmission line employing PACD structure was 8% of the conventional microstrip transmission line on GaAs substrate. Using the theoretical analysis, basic characteristic of the transmission line employing PACD (e.g., loss, effective dielectric constant, effective propagation constant, bandwidth ) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on MMIC. Above results indicate that the transmission line employing PACD is a promising candidate for a development of miniaturized passive components on MMIC.

Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media (다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석)

  • Kim, Yoon-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.61-67
    • /
    • 2010
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain (FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

Study of SI Characteristic of Multilayer PCB with a Through-Hole Via (관통형 비아가 있는 다층 PCB의 SI 성능 연구)

  • Kim, Li-Jin;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.188-193
    • /
    • 2010
  • In this paper, SI(Signal Integrity) characteristic of the 4-layer PCB(Printed Circuit Boards) with a through-hole via was analyzed by impedance mismatching between the through-hole via and the transmission line, and deterioration of clock pulse response characteristic due to the P/G plane resonances which are generated between the power and the ground plane. The minimized impedance mismatching between the through-hole via and the transmission line for the improving of SI characteristic is confirmed by the TDR(Time Domain Reflector) simulation and lumped element modeling of the through-hole via. And the cancellation method of P/G plane resonances for improvement of the SI characteristic is represented by simulation result.

Power Divider using Shunt Open-Stub Loaded Transmission Line (병렬 오픈 스터브가 연결된 전송선로를 이용한 전력분배기)

  • Kwan, Sang-Gun;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.774-780
    • /
    • 2011
  • This paper presents a Bagley polygon and Gysel divider using open-stub loaded transmission line. The structure of slow-wave characteristic consists of small transmission line and shunt capacitive open stub that have reduced characteristic impedance and phase velocity, so we can implement the small circuit size. To validate the slow-wave characteristics, we are implemented the slow-wave characteristic of Bagley polygon and Gysel divider at center frequency 2.1 GHz. Its characteristics are same, but the circuit size is reduced above 15 % respectively.

Influence on the Torsional Vibration of Input Shaft and the Vibration of Vehicle by Damper Clutch in Auto-Transmission (자동변속기의 댐퍼 클러치가 Input Shaft 의 비틀림 진동 및 차체 진동에 미치는 영향 연구)

  • Jung, Byung-Hwan;Hwang, Seon-Yang;Kang, Koo-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.344-350
    • /
    • 2009
  • According to torsional vibration characteristic of a damper clutch in auto-transmission, the input shaft system have occurred breakdown for the duration cycle and over-vibration happened on vehicle at specific condition. This paper describes the improvement of the torsional vibration of input shaft and the vehicle vibration by tuning of the damper clutch and suggests to the guide line about torsion characteristic on the design of damper clutch.

  • PDF