• 제목/요약/키워드: Transmission Tube

검색결과 228건 처리시간 0.023초

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성 (Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.247-252
    • /
    • 2008
  • 휴대용 XRF(X-Ray Fluorescence) 장치에 적용하기 위하여 개발한 투과 양극형 x-ray tube를 이용하여 XRF 실험을 하고, x-ray tube가 XRF data에 미치는 영향을 조사하였다. W-target tube와 Rh-target tube를 이용하여 측정한 XRF data는 알려진 결과와 잘 일치하였다. 35 kV와 관전압과 $40{\mu}A$의 관전류에서 W-target tube로 측정한 Fe $K_{\alpha}$-line의 FWHM은 약 180 eV로써, 이 값은 물질의 성분분석을 하기에 충분한 것으로 확인하였다. XRF data와 x-ray tube의 적분강도 곡선을 비교 분석해 본 결과, 휴대용 XRF 장치에는 W-Target tube보다는 Rh-Target tube를 사용하는 것이 더 유리함을 밝혀내었다.

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계 (The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials)

  • 이승;안민홍;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF

필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성 (Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.240-246
    • /
    • 2008
  • 수십에서 수백 ${\mu}m$ 영역의 필름 두께 측정에 적용하기 위한 Ag-target 투과양극형 x-ray tube를 개발하고 특성을 조사하였다. 10kV 부근의 관전압에서 x-ray 에너지의 분포 및 선량특성을 조사하고 W-target tube와 비교하여 논의하였다. 또한 Ag-target tube와 W-target tube를 이용하여 Ny film과 PP film의 두께변화에 따른 x-ray의 투과 특성으로 조사하였고, 그 결과 개발된 x-ray tube는 필름두께 측정용으로 적용할 수 있을 만큼 충분히 좋은 특성을 나타내었다.

차음시트의 음향투과손실 측정에 관한 연구 (A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets)

  • 이동훈;강문;이주원;정갑철;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석 (Development and Characteristics of the Soft x-ray transmission W-target tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제16권4호
    • /
    • pp.305-310
    • /
    • 2007
  • W-target 투과양극형 x-ray tube를 개발하고, 특성을 조사하였다. 관전압이 12kV이하에서는 연속 x-ray만 방출되었고, 12kV 이상에서부터 특성 x-ray가 관측되었다. 연속 x-ray와 특성 x-ray의 에너지 분포 및 선량 특성을 조사한 결과 알려진 결과와 잘 일치함을 알 수 있었다. 또한 상용화된 제품과의 비교에서, 기존 제품 이상의 성능을 가질 수 있음을 확인하였다. 따라서 본 연구에서 개발된 x-ray tube는 상용화할 수 있을 만큼 충분히 우수한 특성을 가지고 있음을 확인하였다.

40kV용 투과 양극형 x-ray tube의 개발 및 특성분석 (Development and its Characteristics of the 40kV x-ray transmission anode target tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.234-239
    • /
    • 2008
  • 휴대용 XRF (X-Ray Fluorescence) 장치에 적용할 수 있는 40 kV용 투과 양극형 W-Target tube와 Rh-Target tube를 개발하고 특성을 조사하였다. 특성 x-ray의 에너지와 연속 x-ray의 선량특성은 알려진 결과와 잘 일치함을 확인하였고, 최대 선량을 추출하기 위한 양극금속 박막의 최적 두께는 W-target tube의 경우 약 $2.6{\mu}m$, Rh-target tube의 경우 약 $2.7{\mu}m$ 임을 밝혀내었다. 또한 관전압 40 kV, 관전류 $60{\mu}A$로 30분 동안 연속적으로 작동시켰을 때 양극에서의 온도는 $50^{\circ}C$를 넘지 않아 휴대용 XRF장치에 적용할 수 있음을 확인하였다.

펄스 튜브를 이용한 수중 전달 손실 측정에서 간극이 미치는 영향에 대한 고찰 (A Study on the Effect of a Gap in Measurement of Underwater Transmission Loss by Pulse Tube)

  • 서윤호;김상렬;김재승;변양헌;서영수
    • 한국음향학회지
    • /
    • 제34권3호
    • /
    • pp.192-199
    • /
    • 2015
  • 펄스 튜브를 이용하여 시편의 전달 손실 성능을 측정할 경우, 시편 설치를 위해 필연적으로 시편과 펄스 튜브 내벽 사이에 간극이 존재한다. 본 논문에서는 이와 같은 간극이 전달 손실 측정 결과에 미치는 영향에 대해 평가했다. 평면파에 대해 일정 폭 및 길이를 갖는 간극 전과 후 음압의 비를 구하여 전달 계수를 유도하고 측정 대상 시편의 전달 계수와 조합하여 간극이 포함된 시편의 전달 손실을 구했다. 이와 같은 해석 모델을 이론해가 존재하는 10 mm 두께의 스테인리스 스틸 시편에 적용하여 시험 결과와 비교함으로서 해석 모델의 적절성을 보였다. 마지막으로 해석 모델을 통하여 간극크기 및 시편 전달 손실 성능에 따라 전달 손실 측정에 미치는 영향을 분석했다.

Free molecule transmission probability of a conical tube with wall sorption

  • 인상렬
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1998
  • The uniform distributed pumping model is used to derive analytic expressions of the pressure profile for the molecular flow regime in linearly tapered or flared(conical or pyramidal) tubes with wall sorption. The concept of transmission conductance for sticky tubes of arbitrary shape is newly introduced to calculate the transmission probability using the pressure profile. The transmission probability obtained analytically for a conical sticky tube is compared with that from the Monte Carlo simulation.

분자류에서 도관의 연결부에 나타나는 빔 효과와 그림자 효과 (Beam and shadow effects occurring at connetions of tubes in the molecular flow)

  • 인상렬
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 2000
  • An unexpected error is produced in calculating the transmission probability of a multipartite duct because of beam and shadow effects, if using a simple summation rule like the Oatley's equation. Particles moving in a tube are directed more or less towards the axis of the tube by the beam effect, and the length of a compound tube shortens virtually by the shadow effect originated from a reduction in the number of particles reaching the corner between two tubes of different cross-sections. Both effects make the transmission probability of the tube connected behind and consequently of the whole duct increase slightly. In this paper sources of the error in the calculation of the transmission probability are analyzed quantitatively and variations in the error depending on the dimensions of cylindrical tubes are calculated.

  • PDF