• 제목/요약/키워드: Transmission Line Carrying Capacity

검색결과 5건 처리시간 0.019초

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

345KV 송전선의 과도안정도계산 I (A study on transient stability of 345 KV power transmission line)

  • 이재숙
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.24-29
    • /
    • 1969
  • This is preliminary study concerning the future construction and operation of 345KV power transmission line in Korea which will be added to the existing 161KV power system by the end of 1970 in order to increase the power carrying capacity between Seoul and Pusan area; 350 kilo meters aparts, in accordance with the ambitious second five years power development schedule of Korea Electric Company. The result of this study says that an intermidiate switching station should be installed at the middle position of the line to improve the transient stability of the system, considerable amount of capacitors or synchronous condenser are to be installed to reduce the voltage drop at receving end of line during the heavy load hours, and also in some measure to avoid the voltage rise by self-excitation of power generators during the light load hours and while energizing the line. This is the first attempt to realize the EHV power transmission line in Korea so that the additional study is necessary on the kind and size of conductors, the necessary number of insulators and the suitable clearance distances between conductor and steel tower or earth from the technical and economical view points. These are necessary steps to be taken by the writer before getting into the calculation on the transient stablity of the power system.

  • PDF

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

전력선 용량증대를 위한 해저케이블 설계 (Design of Submarine Cable for Capacity Extension of Power Line)

  • 손홍철;문채주;김동섭
    • 한국전자통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.77-84
    • /
    • 2022
  • 해저 전력케이블은 수면 아래로 전력을 운송하는 송전케이블이다. 최근 해저케이블은 해상의 재생에너지인 풍력, 파력 및 조류시스템 등의 전력을 육지로 전송하며, 이 케이블이 위치하는 장소에 따라 해저에 매설하거나 해저면에 놓여진다. 전력케이블은 극한 환경에서 이용되어 왔기 때문에 가혹한 조건들과 온도 및 강한 조류를 견디도록 제작되나, 해저조건은 해상케이블에 대해 수 많은 종류의 심각한 손상을 만들기에 충분한 조건을 갖는다. 이러한 원인은 전력전송을 중단시키는 케이블 손상을 가져온다. 본 논문에서는 케이블에 대한 설계기준과 시공절차와 난제 그리고 케이블 전환 접속시스템에 대하여 연구한다. 설계된 해저케이블의 규격은 154kV 기존 케이블 1회선과 신규 케이블 2회선 등 3회선으로 구성되고, 선로당 100MVA 전력용량을 갖는다. 해저케이블 매설깊이를 결정하고 기존 및 신규 케이블을 함께 배치하는 방법을 연구하였다. 지중선로에 대한 해저케이블의 전력용량 허용값을 계산하였고 그 결과 케이블 선로당 100MW 이상의 전력용량을 갖는다는 것을 확인하였다.

콘크리트 손상 모델을 적용한 콘크리트 구조물 구조내력 해석 (Numerical Analysis of Load Carrying Capacity of RC Structures Based on Concrete Damage Model)

  • 우상균;이윤;이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.121-128
    • /
    • 2012
  • 이 논문에서는 대표적 수치해석에의 균열처리 방법으로 손상모델 기반의 분산균열모델을 체택하여 구조내력을 산정하였다. 또한 전력구 구조물의 실구조 모델링을 위해 3차원 해석방법을 택하였으며 3차원 콘크리트 구성모델로는 현재 3차원 모델중 콘크리트의 다축압축, 인장균열을 효과적으로 모사하는 미소면 모델(Microplane model)을 재료모델로 사용하여 비선형 유한요소해석을 수행하였다. SFRC의 인장연화곡선을 얻기 위해 역해석법을 사용하였으며, 역해석으로 구한 인장연화곡선이 실험결과와 아주 잘 일치함을 보였다. 하중-균열폭 관계를 입력값으로 사용한 역해석 결과와 하중-CMOD 관계를 사용한 역해석 결과는 서로 잘 일치하는 경향을 나타냈다. 이 논문에서는 실험으로부터 측정된 균열폭 데이터와 수치해석시의 손상지수와의 관계를 도출하여으며, 이와 같은 결과는 향후 균열탐사를 통한 구조물의 잔존 구조내력 산정에 적용할 수 있으리라 판단된다.