• Title/Summary/Keyword: Transmission Area

Search Result 1,870, Processing Time 0.033 seconds

Transmission Electron Microscopy Specimen Preparation for Layer-area Graphene by a Direct Transfer Method

  • Cho, Youngji;Yang, Jun-Mo;Lam, Do Van;Lee, Seung-Mo;Kim, Jae-Hyun;Han, Kwan-Young;Chang, Jiho
    • Applied Microscopy
    • /
    • v.44 no.4
    • /
    • pp.133-137
    • /
    • 2014
  • We suggest a facile transmission electron microscopy (TEM) specimen preparation method for the direct (polymer-free) transfer of layer-area graphene from Cu substrates to a TEM grid. The standard (polymer-based) method and direct transfer method were by TEM, high-resolution TEM, and energy dispersive X-ray spectroscopy (EDS). The folds and crystalline particles were formed in a graphene specimen by the standard method, while the graphene specimen by the direct method with a new etchant solution exhibited clean and full coverage of the graphene surface, which reduced several wet chemical steps and accompanying mechanical stresses and avoided formation of the oxide metal.

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.4
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

A An Experimental Study for Load Capacity and Dip Characteristic in Overhead Transmission Lines (가공송전선의 부하용량과 이도 특성에 관한 실험적 연구)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.177-183
    • /
    • 2010
  • Overhead transmission lines in domestic area have been built by several different design standards of dip and ground clearance. This paper describes an experimental study for evaluating load capacity and dip margin in overhead transmission lines. Such design standards for selection of overhead transmission conductors, dip and ground clearance, as well as electrical equipment technical standard are discussed. Based on daily load and weather data, several characteristics such as line utilization factor, load factor, conductor temperature and dip, etc. are analyzed, and compared with the specified levels of design standards. As a result, it is verified that DLR method can be a clue of the solving of the problem, for occurring in old transmission conductors which may be rarely operating below standards.

Multi-Area Economic Dispatch Considering Environmental Emission and Transmission Losses (연계 계통에서의 환경적 배출량과 손실을 고려한 최적 경제급전)

  • Choi, Seung-Jo;Rhee, Sang-Bong;Kim, Kyu-Ho;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.341-343
    • /
    • 2000
  • Traditionally electric power system are operated in such a way that the total fuel cost is minimized regardless of accounting for tie-lines transmission constraint and emissions produced. But tie-lines transmission and emissions constraint are very important issues in the operation and planning of electric power system. This paper presents the Two-Phase Neural Network(TPNN) to solve the Economic Load Dispatch (ELD) problem with tie-lines transmission and emissions constraint considering transmission losses. The transmission losses are obtained from the B-coefficient which approximate the system losses as s quadratic function of the real power generation. By applying the proposed algorithm to the test system, the usefulness of this algorithm is verified.

  • PDF

Smartphone Real Time Streaming Service using Parallel TCP Transmission (병렬 TCP 통신을 이용한 스마트폰 실시간 스트리밍 서비스)

  • Kim, Jang-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.937-941
    • /
    • 2016
  • This paper proposed an efficient multiple TCP mechanism using Android smartphones for remote control video Wi-Fi stream transmission via network communications in real time. The wireless video stream transmission mechanism can be applied in various area such as real time server stream transmissions, movable drones, disaster robotics and real time security monitoring systems. Moreover, we urgently need to transmit data in timely fashion such as medical emergency, security surveillance and disaster prevention. Our parallel TCP transmission system can play an important role in several area such as real time server stream transmissions, movable drones, disaster robotics and real time security monitoring systems as mentioned in the previous sentence. Therefore, we designed and implemented a parallel TCP transmission (parallel stream) for an efficient real time video streaming services. In conclusion, we evaluated proposed mechanism using parallel TCP transmission under various environments with performance analysis.

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF

Optimization of Backside Etching with High Uniformity for Large Area Transmission-Type Modulator

  • Lee, Soo-Kyung;Na, Byung-Hoon;Ju, Gun-Wu;Choi, Hee-Ju;Lee, Yong-Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.319-320
    • /
    • 2012
  • Large aperture optical modulator called optical shutter is a key component to realize time-of-flight (TOF) based three dimensional (3D) imaging systems [1-2]. The transmission type electro-absorption modulator (EAM) is a prime candidate for 3D imaging systems due to its advantages such as small size, high modulation performance [3], and ease of forming two dimensional (2D) array over large area [4]. In order to use the EAM for 3D imaging systems, it is crucial to remove GaAs substrate over large area so as to obtain high uniformity modulation performance at 850 nm. In this study, we propose and experimentally demonstrate techniques for backside etching of GaAs substrate over a large area having high uniformity. Various methods such as lapping and polishing, dry etching for anisotropic etching, and wet etching ([20%] C6H8O7 : H2O2 = 5:1) for high selectivity backside etching [5] are employed. A high transmittance of 80% over the large aperture area ($5{\times}5mm^2$) can be obtained with good uniformity through optimized backside etching method. These results reveal that the proposed methods for backside etching can etch the substrate over a large area with high uniformity, and the EAM fabricated by using backside etching method is an excellent candidate as optical shutter for 3D imaging systems.

  • PDF

Method for Train Information Transmission using PHS (PHS를 이용한 열차정보 전송 방안)

  • Cho, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.240-241
    • /
    • 2004
  • JP Nagoya. Inc started special work(passenger order} to transmit information to the passenger from 2001 following the eastern area' heavy rain in 2000. They introduced 'Passenger Information System' which uses self communication network(LAN, PHS) mainly and wire/wireless and internet jointly. As an information transmission method of this system, there is "train information transmission using PHS" which transmits info to LED display in special train. This system configured by adding new equipments and using existing equipments, network in maximum, this study reviewed the system, which transmits real time operation condition unified by these passenger order to passenger in high quality, more promptly.

  • PDF

Optical Interface in Consumer Electronics (가전기기에서의 광접속의 활용)

  • 문종국;이동현;강희종
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.224-226
    • /
    • 2000
  • Consumer electronics is rapidly digitalized invoking the necessity of digital signal transmission. Moreover, even in consumer electronics, occasionally signal speed is over 1Gbps and long distance transmission(over 5 meters) is required. For these requirements, even though optical transmission is ideal, cost problem has blocked up its entrance to consumer market. However, inexpensive and high speed optical devices such as VCSEL, PIN or MSN PD with large detecting area and low capacitance and Plastic Optical Fiber have been developed so that optical solution can be compete with electrical one in consumer electronics.

  • PDF

Strategies for Minimizing Forest Disturbance During the Construction of Power Transmission Towers (송전선로 건설에 따른 산림훼손의 최소화 관리방안)

  • 이동근;강현경
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.6
    • /
    • pp.66-78
    • /
    • 2003
  • The purpose of this study was to minimize the forest disturbance around an entry road of a power transmission tower construction site between Taean and Sinsesan, Chungnam. The main study field was classified into existing materials and a GIS, remote sensing analysis, and a field examination. This information was used to identify the most suitable entry road using a degree of green naturality map, eco-naturality map, actual vegetation map, and a forest state map as the existing materials. Also, the study used an normalized difference vegetation index, altitude and slope map in order to make the evaluation materials which used an remote sensing image, and GIS. This data was used to choose an optimum area, and diagnosed the current condition of the vegetation with a field survey of the area. It analyzed vegetation structure, species diversity, the age of trees in a field examination. Subsequently, we proposed four area types based on the analysis results--preservation area, transplantation area, restoration area and development area. As a result, the preservation area was categorized into 8 grades, according to the degree of green naturality, large area of breast diameter at Pinus densiflora community, competition area of Pinus densiflora and Quercus spp. and Quercus spp. community of over 20 years old. A transplantation area established 46 optimum areas according to the GIS analysis and vegetation investigation results. Vegetation restoration plan for disturbance area should be made based on ecological value of existing vegetation to worthwhile area as Quercus spp. mixing forest proposed. The development area selected a ecological worthless place as an artificial forest where Pinus densiflora and Pinus thunbergii growth is poor. This research results suggest that restoration of vegetation will be possible in the real world. Also, ecological restoration guidelines will be made through building and analyzing data base and routine monitoring of transplantation and restoration area.