• 제목/요약/키워드: Transient power coupling

검색결과 61건 처리시간 0.029초

장거리 벨트 컨베이어의 기동 및 정지시의 동적거동 해석 (Dynamic Analyis of Long Distance Belt Conveyor During Starting and Stopping)

  • 김원진;박태건;이신섭
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.585-593
    • /
    • 1996
  • According to the considerable increase of the length of belt conveyors, the dynamic analysis of systme becomes necessary to consider the variation of tensions and transient motion of components during starting and stopping of conveyor. The mathematical model of system is derived using the lumped parameter method. The input driving force is represented with two functions of time and pulley speed to count the characteristics of motor and fluid coupling. An example system was studied with 14 km in the distance of carrying. At head, it has two drivers and one gravity take-up and at tail ond driver and one power winch take-up. In the example, the transient tensions and responses, calculated using two cases of driving force, are mutually compared in starting mode. Also, the position of maximum tension and the braking force of take-up are obtained in stopping mode.

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.

광대역 고출력 전자기 펄스에 의한 마이크로컨트롤러 소자의 매개변수들의 민감성 분석 (The Sensitivity of the Parameters of Microcontroller Device with Coupling Caused by UWB-HPEM (Ultra Wideband-High Power Electromagnetics))

  • 황선묵;홍주일;허창수
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.369-373
    • /
    • 2010
  • Modem electronic circuits are of importance for the function of communication, traffic systems and security systems. An intentional threat to these systems could be of big casualties and economic disasters. This paper has shown damage effect of microcontroller device with coupling caused by UWB-HPEM(Ultra Wideband-High Power Electromagnetics). The UWB measurements were done at an Anechoic Chamber using a RADAN UWB voltage source, which can generate a transient impulse of about 180 kV. The susceptibility level for microcontroller has been assessed by effect of various operation line lengths. The results of susceptibility analysis has showed that the effect of the reset line length on the MT(Ma1function Threshold) is larger than the effect of the different line length(Data, Power, Clock). With the knowledge of these parameters electronic system can be designed exactly suitable concerning the system requirements. Based on the results, susceptibility of microcontroller can be applied to protection plan to elucidate the effects of microwaves on electronic equipment.

Study of Hydrodynamic-Magnetic-Thermal Coupling in a Linear Induction MHD Pump

  • Kadid, Fatima Zohra;Drid, Said;Abdessemed, Rachid
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.249-254
    • /
    • 2009
  • This article deals with the analysis of a coupling between stationary Maxwell's equations, the transient state Navier-Stokes and thermal equations. The resolution of these equations is obtained by introducing the magnetic vector potential A, the vorticity ${\xi}$, the stream function ${\psi}$ and the temperature T. The flux density, the electromagnetic thrust, the electric power density, the velocity, the pressure and the temperature are graphically visualized. Also, the influence of the frequency is presented.

CUPID 코드와 MARS 코드를 이용한 기기/계통 다중스케일 연계 해석 코드 구현 (COMPONENT AND SYSTEM MULTI-SCALE DIRECT-COUPLED CODE IMPLEMENTATION USING CUPID AND MARS CODES)

  • 박익규
    • 한국전산유체공학회지
    • /
    • 제21권3호
    • /
    • pp.89-97
    • /
    • 2016
  • In this study, direct code coupling, in which two codes share a single flow field, was conducted using 3-dimensional high resolution thermal hydraulics code, CUPID and 1-dimensional system analysis code, MARS. This approach provide the merit to use versatile capability of MARS for nuclear power plants and 3-dimensional T/H analysis capability of CUPID. Numerical Method to directly couple CUPID and MARS was described in this paper. The straight flow and manometer flow oscillation were calculated to verify conservation of coupled CUPID/MARS code in mass, momentum, and energy. This verification calculations indicates that the CUPID/MARS is coupled appropriately in numerical aspect and the coupled code can be applied to nuclear reactor thermal hydraulics after validation against integral transient experiments.

개선된 SIME법을 이용한 과도 안정도 평가 (Transient Stability Assessment Using Improved SIME)

  • 이종석;안태형;양정대;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.258-260
    • /
    • 1999
  • The Single Machine Equivalent(SIME) is a hybrid method resulting from the coupling of a time-domain program with the equal-area criterion. This paper presents the efficient filtering algorithm using improved SIME for Transient Stability Assessment. The main feature of the method is cascading contingency filtering. First contingency filtering is conducted by using the first-swing stability of equivalent One Machine Infinite Bus(OMIB) system. This stability is evaluated by checking its time trajectory. Selected cases through the first step are assessed on the second step using SIME under the detailed model of power systems. The efficiency of the algorithm is tested on PSS/E test system.

  • PDF

커플링/디커플링 네트워크 내장 서지발생장치의 설계 및 제작 (Design and Fabrication of a Surge Generator with Coupling/Decoupling Networks)

  • 김남훈;강태호;신한신;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권2호
    • /
    • pp.130-134
    • /
    • 2020
  • Metal oxide varistors (MOVs) protect circuits and devices from transient overvoltages in electric power systems. However, a MOV continuously deteriorates owing to manufacturing defects or repetitive protective operations from transient overvoltages. A deteriorated MOV may result in a short circuit or a line-ground accident. Previous studies focused on the analysis of deterioration mechanisms and condition diagnosis techniques for MOVs owing to their recent growth of use. An accelerated deterioration experiment under the same conditions in which a MOV operates is essential. In this study, we designed and fabricated a surge generator that can apply a surge current to a MOV connected to AC mains. The coupling network operates at a low impedance against the surge current from the surge generator and transfers the surge current to the MOV under test. It also acts as a high impedance against AC mains for the AC voltage not to be applied to the surge generator. The decoupling network operates at a high impedance against the surge current and blocks the surge current from AC mains. It also acts as a low impedance against AC mains for the AC voltage to be applied to the MOV under test. The prototype surge generator can apply the 8/20 us up to 15 kA on AC voltages in the approximate range of 110~450 V, and it fully operates on a LabVIEW-based program.

Dynamic Characteristic Analysis of SSSC Based on Multi-bridge PAM Inverter

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.539-545
    • /
    • 2001
  • This paper proposes a static synchronous series compensator based on multi-bridge inverter. The proposed system consists of 6 H-bridge modules per phase, which generate 13 pulses for each half period of power frequency. The dynamic characteristic was analyzed by simulations with EMTP code, assuming that it is inserted in the 154-kV transmission line of one-machine-infinite-bus power system. The feasibility of hardware implementation was verified through experimental works using a scaled model. The proposed system does not require a coupling transformer for voltage injection, and has flexibility in expanding the operation voltage by increasing the number of H-bridge modules.

  • PDF

A transport model for high-frequency vibrational power flows in coupled heterogeneous structures

  • Savin, Eric
    • Interaction and multiscale mechanics
    • /
    • 제1권1호
    • /
    • pp.53-81
    • /
    • 2008
  • The theory of microlocal analysis of hyperbolic partial differential equations shows that the energy density associated to their high-frequency solutions satisfies transport equations, or radiative transfer equations for randomly heterogeneous materials with correlation lengths comparable to the (small) wavelength. The main limitation to the existing developments is the consideration of boundary or interface conditions for the energy and power flow densities. This paper deals with the high-frequency transport regime in coupled heterogeneous structures. An analytical model for the derivation of high-frequency power flow reflection/transmission coefficients at a beam or a plate junction is proposed. These results may be used in subsequent computations to solve numerically the transport equations for coupled systems, including interface conditions. Applications of this research concern the prediction of the transient response of slender structures impacted by acoustic or mechanical shocks.

Development and validation of multiphysics PWR core simulator KANT

  • Taesuk Oh;Yunseok Jeong;Husam Khalefih;Yonghee Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2230-2245
    • /
    • 2023
  • KANT (KAIST Advanced Nuclear Tachygraphy) is a PWR core simulator recently developed at Korea Advance Institute of Science and Technology, which solves three-dimensional steady-state and transient multigroup neutron diffusion equations under Cartesian geometries alongside the incorporation of thermal-hydraulics feedback effect for multi-physics calculation. It utilizes the standard Nodal Expansion Method (NEM) accelerated with various Coarse Mesh Finite Difference (CMFD) methods for neutronics calculation. For thermal-hydraulics (TH) calculation, a single-phase flow model and a one-dimensional cylindrical fuel rod heat conduction model are employed. The time-dependent neutronics and TH calculations are numerically solved through an implicit Euler scheme, where a detailed coupling strategy is presented in this paper alongside a description of nodal equivalence, macroscopic depletion, and pin power reconstruction. For validation of the steady, transient, and depletion calculation with pin power reconstruction capacity of KANT, solutions for various benchmark problems are presented. The IAEA 3-D PWR and 4-group KOEBERG problems were considered for the steady-state reactor benchmark problem. For transient calculations, LMW (Lagenbuch, Maurer and Werner) LWR and NEACRP 3-D PWR benchmarks were solved, where the latter problem includes thermal-hydraulics feedback. For macroscopic depletion with pin power reconstruction, a small PWR problem modified with KAIST benchmark model was solved. For validation of the multi-physics analysis capability of KANT concerning large-sized PWRs, the BEAVRS Cycle1 benchmark has been considered. It was found that KANT solutions are accurate and consistent compared to other published works.