• Title/Summary/Keyword: Transient Recovery

Search Result 213, Processing Time 0.026 seconds

Investigation of the Impact of Voltage Sags on 3-Phase Induction Motors (순간전압강하가 3상 유도전동기에 미치는 영향 검토)

  • Kang, Bong-Seok;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.361-365
    • /
    • 2004
  • This paper describes the various characteristics of voltage sags which can affect the functions of three-phase induction motors that are mostly used in the power distribution systems. These assorted characteristics include motor speed losses, voltage recovery, motor reacceleration, and transient characteristics. An experimental study on the induction motor behaviors was also carried out to confirm these impacts. In addition sequential voltage sags with short durations were considered and investigated. The results show that the occurrence of the second voltage sag after the first one may affects the induction motor adversely.

  • PDF

Study on interrupting test method for class S2 circuit breaker of distribution system (배전용 S2급 차단기의 차단 성능평가 시험법에 관한 연구)

  • Park, Byung-Rak;Jo, Man-Yong;Kim, Jin-Seok;Shin, Hee-Sang;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.132-139
    • /
    • 2011
  • Technical requirements for medium voltage class circuit breaker were harmonized by IEC and IEEE, and IEC newly adopted the requirements for class S2 circuit-breaker for overhead-line with the ratings of high-frequency TRV(Transient Recovery Voltage), which IEEE already adopted. Under these circumstances, KERI(Korea Electrotechnology Research Institute) studied testing technologies and facilities, which enable to perform interrupting capacity tests for class S2 circuit-breaker. As results, KERI could carry out interrupting capacity tests for medium voltage class circuit breaker rated up to 3-phase 52[kV] 40[kA], which satisfies the IEC standard.

Investigation of the Impact of Voltage Sags and Temporary Interruptions on 3-Phase Induction Motors (배전계통 순간전압강하 및 순간정전이 3상 유도전동기에 미치는 영향 검토)

  • Kang, Bong-Seok;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.106-109
    • /
    • 2003
  • This paper describes the various characteristics of voltage sags and temporary interruptions which can affect the functions of 3-phase induction motors. These assorted characteristics include motor speed loss, voltage recovery, motor reacceleration, and transient characteristics. An experimental study on induction motor behavior was also carried out to confirm these impacts. Besides, sequential voltage sags of short duration were considered for this paper. The results show that the occurrence of the second voltage sag after the first one may affects the induction motor adversely.

  • PDF

Predictive Instantaneous Control of inverter for UPS (UPS용 예측 순시제어형 인버터)

  • Kim, B.J.;Kim, J.H.;Cho, J.H.;Kim, J.S.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.237-239
    • /
    • 1995
  • The inverter for UPS system is required to satisfy pure sinusoidal output voltage with very low THD(Total Harmonic distortion). This paper proposes a TMS320c31 digital signal processor based predictive instantaneous control scheme of inverter. The proposed scheme is able to satisfy the conditions; high capability, high efficiency, low audible noise and robustness of inverter. The transient state characteristics of proposed inverter has been improved. in case of power failure or recovery, nonlinear load, sudden load change or parameters variations. Finally, the performance of the proposed inverter is shown and discussed by simulation and experiment.

  • PDF

The Analysis of Operational Characteristics of Inductive High-Tc Superconducting Fault Current Limiter Concerning Harmonic Component (고조파 성분을 고려한 유도형 고온초전도한류기의 동작 특성 해석)

  • Yim, Do-Hyon;Joo, Min-Seok;Chu, Yong;Kim, Han-Jun;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.131-133
    • /
    • 1995
  • Inductive high-Tc superconducting fault current limiter using YBCO superconducting ring in the secondary part has many advantages in power networks. It is based on the superconducting to normal transition and this paper describes its operational characteristics and experimental results, especially focused on the harmonic component analysis and recovery time. We fabricated and tested it under various conditions for the analysis of transient fault characteristics. And for the analysis of harmonics we used FFT methods. The superconducting ring was quenched in 240Arms and fault current was effectively limited to the lower current level. In addition, it was fast recovered when the fault condition was removed and after fault the system had odd harmonics.

  • PDF

Comparison of Arc Control Ability as a Function of Configuration of Spiral Type VI Contacts by Measuring Arcing Time (아크지속시간 측정을 통한 나선형 VI 전극의 전극배치에 따른 아크제어 성능비교)

  • Kim, byoung-Chul;Park, Hong-Tae;Oh, Ill-Sung;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.184-190
    • /
    • 2009
  • One of the purposes of arc control is to change its state to the diffuse state before current zero as soon as possible. This can provide optimal conditions for full extinction of arc by minimizing the quantity of residual plasma between contacts near current zero. TRV(transient recovery voltage) occurs at current zero at the same time with current interruption. If there is substantial residual plasma near current zero it can cause 'post arc current' by the interaction of its conductance with TRV. In this paper, arc control ability as a function of configuration of spiral type VI contacts was compared on the criteria of the time taken for arc to reach to the diffuse state.

Contralateral Submandibular Retropharyngeal Approach for Recurred High Cervical Chordoma

  • Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.231-233
    • /
    • 2006
  • The C2 level is the transition zone between the cranial and cervical spine. Because of its high position and anatomic relationship to vital structures, exposing C2 is challenging and the surgical approach is controversial. We report a of a recurred chordoma in C2 portion, occupying the osseous intraspinal portion. The patient underwent total corpectomy of C3 and gross total removal of tumor by right submandibular approach 3 years previously. We performed a lateral extrapharyngeal approach from contralateral left side with resection C2 central portion followed by gross total removal of mass and placement of graft bone. Although there was transient hypoglossal nerve palsy postoperatively, the patient had full recovery.

Investigation of the impact of Voltage Sags on 3-Phase Induction Motors Considering Reclosing Interval in Distribution System (리클로징 시간을 고려한 배전계통 순간전압강하의 3상 유도전동기에 미치는 영향 검토)

  • Kang Bong Seok;Kim Jae Chul;Moon Jong Fil;Yun Sang Yun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.45-47
    • /
    • 2004
  • This paper describes the various characteristics of voltage sags which can affect the functions of three-phase induction motors that are mostly used in the power distribution systems. These assorted characteristics include motor speed losses, voltage recovery, motor reacceleration, and transient characteristics. An experimental study on the induction motor behaviors was also carried out to confirm these impacts. In addition, sequential voltage sags with short durations were considered and investigated. The results show that the occurrence of the second voltage sag after the first one may affects the induction motor adversely.

  • PDF

Use of stellate ganglion block for treatment of recurrent syncope followed by chest pain

  • Kim, Young-ung;Shin, Yong-joon;Cho, Young Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.104-108
    • /
    • 2018
  • Syncope is defined as a transient loss of consciousness and postural tone, characterized by rapid onset, short duration, and spontaneous recovery. Stellate ganglion block (SGB) is a nerve block method that is used for treatment of neuropathic pain in the head, neck and upper extremities, especially trigeminal neuralgia, postherpetic neuralgia and complex regional pain syndrome. SGB can modulate and stabilize the sympathetic nervous system, which prevents it from overexcitation and improves symptoms of syncope. The authors report a patient who was treated for pain and edema of both upper extremities with SGB, then showed improvement in recurrent syncope followed by chest pain and overall quality of life.

Caculating Ship Rudder Angle and Real-Time Mass Estimator Under Dynamic State (동적 상태의 선박 조향각 및 실시간 질량 추정 시스템)

  • Jin–hyuk Myung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.06a
    • /
    • pp.31-32
    • /
    • 2022
  • In Early vessels did not provide an exact equation for preventig the capsizing vessels. On land, many vehicle rollover prevention technologies using the steady-state Conrning Equations were developed, which showed better performance than the exiting method at sea. For better performance, It is proposed to improve safety mangement when turning vessel using the Ackerman geometic model-based Cornering Equations in this paper.

  • PDF