• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 0.033 seconds

Development of Power Transformer Maintenance System Using Intelligent Dissolved Gas in Oil Analysis (지능형 유중가스분석법을 이용한 전력용 변압기 관리시스템 개발)

  • Sun, Jong-Ho;Kim, Kwang-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.87-90
    • /
    • 2004
  • This paper describes development of power transformer maintenance system using intelligent dissolved gases in oil analysis. The used gases are acetylene(C2H2), hydrogen(H2), ethylene(C2H4), methane(CH4), ethane(C2H6), carbon monoxide(CO) and carbon dioxide(CO2). The rule and neural network based gas analysis methods are used for artificial intelligent diagnosis. It is indicated that this program is efficient for diagnosis of oil immersed transformers diagnosis from application of gas analysis data of serviced transformer which has local overheating

  • PDF

Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor (전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발)

  • Kim, Ju-Han;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF

A Study on the Risk Assessment for Oil Immersed Transformer of Subway with FN curve (지하철 유입 변압기의 FN 선도를 이용한 위험도 평가 연구)

  • Choi, Seung Hyeok;Lee, Jong Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1152-1158
    • /
    • 2014
  • In Modern society, various important systems is operated such as nuclear plant, chemistry industry, railway system and so on. But these systems can cause high risky accidents. Hence, these systems are required to ensure the individual and societal risk criteria. In this paper, we reviewed EU risk criteria which is already operated in UK and Netherlands, then we proposed acceptable risk criteria and estimated risk of oil immersed transformer for subway with FN curve.

Ana1ysis of Temperature Distribution in Oil-immersed Self-cooled Transformer with Radiator (방열기를 갖는 유입자냉식 변압기의 온도분포 해석)

  • Kim, Joong-Kyoung;Hahn, Sung-Chin;Oh, Yeon-Ho;Park, Kyoung-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.755-756
    • /
    • 2006
  • This paper presents the temperature distribution of the oil-immersed self-cooled transformer with radiator performed by coupled magneto-fluid-thermal analysis. Particularly, 3D temperature distribution of cooling oil and sub-components under the natural convection is obtained by computational fluid dynamics analysis, while heat sources are predetermined by magnetic field analysis using F.E.M. The predicted temperature distribution of the power transformer model is compared with the measured data for verifying the validity of the proposed analysis.

  • PDF

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Study on the synthesis and characterization of soybean based transformer oils (대두유 에스테르계 절연유의 합성과 분석)

  • Han, Dong-Hee;Cho, Han-Goo;Han, Se-Won;Ahn, Myeong-Sang;Oho, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.244-245
    • /
    • 2005
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions of soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. The thermal stability of the esters was determined by thermal gravimetric analysis(TGA).

  • PDF

The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers (주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용)

  • Lee, B.S.;Song, I.K.;Lee, J.B.;Kim, D.M.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

Evaluate the expected price of HTS transformer for introducing into korean power system (초전도변압기의 계통적용을 위한 예상 시장진입가격 추정)

  • Kim, Jong-Yul;Lee, Seung-Ryul;Yoon, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.176-178
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated, which HTS transformer is competitive against conventional transformer.

  • PDF

Development of the Preventive Diagnostic Expert System of Gas in Oil for Power Transformer (변압기 예방진단을 위한 유중가스 전문가 시스템 구축 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;Sun, J.H.;Kim, C.G.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1019-1021
    • /
    • 1999
  • In this paper, we describe the design and appliance of the preventive diagnostic expert system of gas in oil for power transformer. This expert system is developed to use expert system development tool; Element Expert (NEURON DATA Inc.) Analysis is developed by four diagnose methods. In first, the standard of KEPCO is applied. It classifies the state of transformer by four level: Normal, warning, abnormal and danger. And the others are gas pattern methods, IEC code method, and Dornen & Roger Ratio method and applied later. These latter methods analyse the cause of result. Inference engine was designed with Element Expert. In last, we operate the system with sample data and we can obtain the correctly inferred result for the state of transformer.

  • PDF

A Study on the Diagnostic Technique for Distribution Transformers using Multi-Channel Wireless Communication Network (다채널 무선 통신망을 이용한 배전용 변압기 진단 기법에 관한 연구)

  • Kim, Jae-Chul;Choi, Joon-Ho;Kim, Dong-Hyun;Moon, Jong-Pil;Kim, Oun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.131-139
    • /
    • 2001
  • As increasing the accident of Distribution Transformer (DT), we need to manage them efficiently. In this paper, we discusses with the possibility of the diagnostic technique for distribution transformer using relative ageing rate calculation in this paper. The relative ageing rate of the DT could be calculated from the measured top oil temperature, ambient temperature and load current. In order on apply the proposed diagnostic technique we developed an on line Monitoring and Diagnostic System (MDS) which has hardware and software part. Diagnostic device is developed to measure the state information of DT and to send them with R/F(radio frequency) communication. Host computer monitors and saves the receive data. The database is constructed from the data of distributed DT and it is used for estimating loss-of-life in the MDS.

  • PDF