• Title/Summary/Keyword: Transformation power

Search Result 691, Processing Time 0.032 seconds

Research on Discontinuous Pulse Width Modulation Algorithm for Single-phase Voltage Source Rectifier

  • Yang, Xi-Jun;Qu, Hao;Tang, Hou-Jun;Yao, Chen;Zhang, Ning-Yun;Blaabjerg, Frede
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.433-445
    • /
    • 2014
  • Single phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). As the fundamental part of large scale PECs, single-phase VSC has a wide range of applications. In the paper, as first, on the basis of the concept of the discontinuous pulse-width modulation (DPWM) for three-phase VSC, a new DPWM of single-phase VSR is presented by means of zero-sequence component injection. Then, the transformation from stationary frame (abc) to rotating frame (dq) is designed after reconstructing the other orthogonal current by means of one order all-pass filter. Finally, the presented DPWM based single-phase VSR is established analyzed and simulated by means of MATLAB/SIMULINK. In addition, the DPWMs presented by D. Grahame Holmes and Thomas Lipo are discussed and simulated in brief. Obviously, the presented DPWM can also be used for single-phase VSI, GCI and APF. The simulation results show the validation of the above modulation algorithm, and the DPWM based single-phase VSR has reduced power loss and increased efficiency.

Wideband Power Divider Using a Coaxial Cable (동축선을 이용한 광대역 전력 분배기)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.661-668
    • /
    • 2012
  • A coaxial-cable impedance transformer that can be used in high power and wideband frequency range is an arbitrary impedance transformation ratio by an additional coaxial cable. The coaxial-cable impedance transformer to be 50-${\Omega}$ to 25-${\Omega}$ impedance transformation ratio is easily operated an wideband power divider by connecting two 50-${\Omega}$ lines at 25-${\Omega}$ impedance point. This wideband power divider has a poor output matching characteristic and a poor isolation characteristic between two output ports. In this paper, it proposes a coaxial-cable power divider to be a good output matching and isolation characteristics as it uses the singly terminated filter design theory. The odd-mode operation characteristic of the suggested power divider to use singly terminated low pass filter coefficient due to matching order and ripple value is examined by ADS program. And, it fabricates and measures the operation characteristic of 2-way power divider with 2nd-order and 4th-order matching circuit.

Guideline on Security Measures and Implementation of Power System Utilizing AI Technology (인공지능을 적용한 전력 시스템을 위한 보안 가이드라인)

  • Choi, Inji;Jang, Minhae;Choi, Moonsuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.399-404
    • /
    • 2020
  • There are many attempts to apply AI technology to diagnose facilities or improve the work efficiency of the power industry. The emergence of new machine learning technologies, such as deep learning, is accelerating the digital transformation of the power sector. The problem is that traditional power systems face security risks when adopting state-of-the-art AI systems. This adoption has convergence characteristics and reveals new cybersecurity threats and vulnerabilities to the power system. This paper deals with the security measures and implementations of the power system using machine learning. Through building a commercial facility operations forecasting system using machine learning technology utilizing power big data, this paper identifies and addresses security vulnerabilities that must compensated to protect customer information and power system safety. Furthermore, it provides security guidelines by generalizing security measures to be considered when applying AI.

Analysis of Control Characteristics of High Power Hybrid Multilevel PWM Rectifier (대용량 하이브리드 멀티레벨 PWM 정류기의 제어특성 해석)

  • 최남섭
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.262-265
    • /
    • 2000
  • This paper presents analysis of control characteristics of high power hybrid multilevel PWM rectifier without bulky and heavy isolation transformers. It will be shown that the DC voltages for multilevel output generation may be directly built up from AC utility source. The multilevel PWM rectifier is analyzed by using the circuit DQ transformation whereby the static and dynamic characteristics and some useful design equations are obtained. Finally to confirm the validity of the analysis MATLAB simulation are carried out.

  • PDF

Design of a decentralized multilevel control for thermal power plant (발전플랜트의 다단계 분산제어기 설계)

  • 이은호;김석우;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1217-1220
    • /
    • 1996
  • For the purpose of the good tracking to variable load demands of the thermal power plant, a decentralized multilevel control(DMC) scheme is presented. It is applied to the drum type boiler-turbine system which is simplified from Boryung T/P #1,2 model[4]. A linearized model is decomposed into three subsystems by means of linear transformation. Then the DMC based on such subsystem is designed. Simulation using Matlab-Simulink shows that the proposed algorithm works very well to the large step change of power demand.

  • PDF

THE DETECTION OF INSTANTANEOUS DISTORTED CURRENT WITH THREE-DIMENSIONAL SPACE VECTOR

  • Mei, Tong;Jie, Tong;Jingpin, Jiangg
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.615-619
    • /
    • 1998
  • Active power filter is a kind of device used for compensating instantaneous reactive and harmonic current in three-phase circuits. An essential technology that determines the behavior of an active power filter is the method of detecting the distorted current. Using three-dimensional space vectors, this paper describes a simple method for detecting the distorted current without any coordinate transformation. The effectiveness of the novel method is verified by the theoretical analysis and simulation.

  • PDF

Development of Special Steels for Turbine Blade of Nuclear Power Plant (원자력 터빈 블레이드용 특수강 개발)

  • Im, Cha-Yong;Kim, Seong-Jun
    • 연구논문집
    • /
    • s.24
    • /
    • pp.119-128
    • /
    • 1994
  • A special steels have been developed for the possible applications of turbine blade in nuclear power plant. The compositions of developed alloy were selected by the reference of imported alloy. The various properties such as tensile property, impact energy, hardness, and microstructures were investigated. All the properties of optimum heat treated materials were satisfied with the present specifications of turbine blade materials in unclear power plant. Furthermore, FATT(Fracture appearance transition temperature), high temperature tensile properties, and transformation temperatures of developed alloy also have been studied.

  • PDF

Sensorless Control of the Synchronous Reluctance Machine

  • Kilthau A.;Pacas J. M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.768-772
    • /
    • 2001
  • The paper deals with the control of the synchronous reluctance machine without position sensor. A method for the computation of the transformation angle out of terminal voltages and currents is presented. The injection of test signals allows operation at zero speed. Fundamental for this control scheme is the exact modelling of the machine, where especially the saturable inductances are of central interest. The accuracy of the angle estimation method over the whole operating range including field-weakening is discussed in detail. The implementation of the angle estimation method in a rotor-oriented control scheme and practical results are demonstrated.

  • PDF

A Study on Constant Power Generation Algorithms for a Whole Range Power Point Tracking in Photovoltaic Systems (태양광 시스템의 전 범위 전력점 추종을 위한 CPG 알고리즘에 관한 연구)

  • Yang, Hyoung-Kyu;Bang, Taeho;Bae, Sunho;Park, Jung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • In this study, constant power generation (CPG) algorithms are introduced for whole range power point tracking in photovoltaic systems. Currently, maximum power point tracking (MPPT) algorithm is widely used for high-power photovoltaic systems. However, MPPT algorithm cannot flexibly control such systems according to changing grid conditions. Maintaining grid stability has become important as the capacity of grid-connected photovoltaic systems is increased. CPG algorithms are required to generate the desired power depending on grid conditions. A grid-connected photovoltaic system is configured, and CPG algorithms are implemented. The performances of the implemented algorithms are compared and analyzed by experimental results.

Modeling of an Shape Memory Alloy Actuator (형상기억합금 작동기의 모델링)

  • Lee H.J.;Yoon J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1812-1818
    • /
    • 2005
  • Even though SMA actuators have high power to volume ratio, there exist disadvantages such as hysteresis and saturation. So the model identification for SMA actuators is very difficult. For the qualitative model identification, we described the behavior of SMA actuators using a so-called diagonal model, which can readily expect the turning point of an incomplete phase transformation. For the quantitative model identification, we developed the general dynamics of SMA actuators using the modified Liang's model. Using this dynamics we can describe the hysteresis and the saturation very well. It is also very important to notice that the modified Liang's model maintains a continuous martensite fraction at the change of the phase transformation but the original model cannot.

  • PDF