• Title/Summary/Keyword: Transfer resistance

Search Result 1,288, Processing Time 0.028 seconds

Modelling Heat Transfer Through CRUD Deposited on Cladding Tube in UNIST-DISNY Facility (UNIST-DISNY 설비 피복관에 침적된 크러드의 열전달 모델링)

  • Seon Oh YU;Ji Yong Kim;In Cheol Bang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.109-116
    • /
    • 2023
  • This study presents a CRUD modelling to simulate the thermal resistance behavior of CRUD, deposited on the surface of a cladding tube of a fuel assembly. When heat produced from fuels transfers to a coolant through a cladding tube, the CRUD acting as an additional thermal resistance is expressed as two layers, i.e., a solid oxide layer and an imaginary fluid layer, which are added to the experimental tube's heat structure of the MARS-KS input data. The validation calculation for the experiments performed in UNIST-DISNY facility showed that the center and surface temperatures of the cladding tube increased as the porosity and the steam amount inside pores of the CRUD got higher. In addition, the temperature gradient in the imaginary fluid layer was calculated to be larger than that in the solid oxide part, indicating that the steam amount inside the layer acted more largely as thermal resistance. It was also evaluated through sensitivity calculations that the cladding tube temperature was more sensitive to the CRUD porosity and the steam amount in pores than to the inlet flow rate of the coolant.

Conjugate Heat Transfer Characteristics in a Ribbed Channel:Effect of Reynolds Number and Heat Capacity Ratio (요철이 설치된 채널 내에서 레이놀즈수와 열용량비에 따른 복합열전달 특성)

  • Song, Jeong-Chul;Ahn, Joon;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2297-2302
    • /
    • 2007
  • Numerical simulations are conducted to analyze conjugate heat transfer characteristics in a ribbed channel. In this simulation, the effects of Reynolds number and heat capacity of the solid channel wall on convective heat transfer are observed in the turbulent flow regime. In the case of the conducting wall against isothermal wall, the relative ratio of the thermal resistance between the solid wall and the flow field varies with Reynolds number. Thus the characteristics of the conjugate heat transfer are changed with the Reynolds number. Heat capacity ratio affects the temperature fluctuation inside solid wall. The temperature fluctuation inside the solid wall decreases with increasing the heat capacity of the solid wall so that the convective heat transfer increases. When the thermal conductivity ratio is smaller than 10, the effects of flow characteristics on heat transfer are changed.

  • PDF

Heat Transfer Optimization in a Tube with Circular-Sectored Fins (원관내 부채꼴 휜 주위에서의 열전달 최적화)

  • Yoo, Jae-Wook;Kim, Sung-Jin;Hyun, Jae-Min
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.57-64
    • /
    • 2000
  • The present work investigates the heat transfer characteristics for laminar fully developed forced convection in an internally finned tube with axially uniform heat flux and peripherally uniform temperature through analytical models of convection in a porous medium. Using the Brinkman-extended Darcy flow model and the two equation model fur heat transfer, analytical solutions fur fluid flow and heat transfer are obtained and compared with the exact solution for fluid flow and the numerical solutions for conjugate heat transfer to validate the porous medium approach. Using the analytical solutions, parameters of engineering importance are identified and their effects on fluid flow and heat transfer are studied. Also, the expression fur total thermal resistance is derived from the analytical solutions and minimized in order to optimize the thermal performance of the internally finned tubes.

  • PDF

A Stochastic Transit Assignment Model on Railway Network (철도 네트워크에서의 확률적 통행 배정 모형 연구)

  • Park, Bum-Hwan;Kim, Chung-Soo;Rho, Hag-Lae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1222-1230
    • /
    • 2010
  • This study is about developing a transit assignment model on railway network. Current transit assignment models are mainly focused on road or urban transportation so that these models, for example, transit assignment model based on optimal strategy generates unrealistic transit assignment. Especially, since the advent of KTX, more passengers are using the transfer route containing KTX but most transit assignment models have a shortcoming that transfer is not considered or is overestimated. We present a new stochastic transit assignment model based on LOGIT considering transfer resistance.

  • PDF

Comparison of Various Methods for Estrus Stage Determination in Bitch (개의 발정 진단 방법에 따른 효율 비교)

  • Ko, Young-Jin;Kang, Eun-Ju;Lee, Sung-Lim
    • Journal of Embryo Transfer
    • /
    • v.24 no.3
    • /
    • pp.131-137
    • /
    • 2009
  • In dogs, correct diagnosis of estrus is important and the exact time of ovulation can be determined by variouse methods. Vaginal cytology has commonly used in conjunction with the physical examination, clinical history, vaginoscopy, and hormonal assays to determine the stage of the reproductive cycle. This study was therefore investigated the effectiveness of direct ovulation detector designed by changes of electrical resistance in vaginal mucus following different estrus cycles with several methods; vaginal cytology, concentration of plasma estrogen and progesterone, and direct examination by laparotomy. A total of 12 bitches was selected for the study and observed estrus signs. The bitches were evaluated clinical sign (vulvar swelling and bleeding), cytological examination (keratocyte and RBC), electrical resistance, plasma estrogen and progesterone concentration for estrus assessment. Accuracy of ovulation detection by vaginal cytology was significantly (p<0.05) lower than those by electrical resistance and plasma progesterone concentration, based on the confirmation by laparotomy. Vaginal smear is not confidential method compared to detection of electrical resistance and plasma progesterone concentration at ovulation. Although the value of electrical resistance was varied at the same points of estrus in individuals, ovulation was occurred at the first day which shown the peak of electrical resistance and mating time was third day after peak. In conclusion, ovulation detector designed by changes of electrical resistance is an effective and economic instrument for predicting estrus and ovulation in bitches.

Effect of Si Addition on the Corrosion Resistance of CrN Coatings in a Deaerated $3.5wt.\%$ NaCl Solution (탈기된 $3.5wt.\%$ NaCl 용액 환경에서의 스테인리스 강에 증착된 CrN 박막의 Si 첨가에 따른 영향 평가)

  • Kim Woo-Jung;Choi Yoon-Seok;Kim Jung-Gu;Lee Ho-Young;Han Jeon-Gun
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.4
    • /
    • pp.137-143
    • /
    • 2005
  • CrSiN coatings of stepwise changing Si concentration were deposited on stainless steel by closed field unbalanced magnetron sputtering (CFUBM) system. Microstructure of the films due to the Si concentration is measured by XRD. The corrosion behavior of CrSiN coatings in deaerated $3.5\%$ NaCl solution was investigated by potentiodynamic test, electrochemical impedance spectroscopy (EIS) and surface analyses. The microstructure of CrSiN film depends on the Si concentration. When Si/(Cr+si) was under $11.7\%$, preferred orientation is defined at CrN(220), CrN(311) and $Cr_2N(111).$ The results of potentiodynamic polarization tests showed that the corrosion current density and porosity decreased with increasing Si/(Cr+si) ratio. EIS measurements showed that the corrosion resistance of Si-bearing CrN was improved by phase transformation of the film, which leads to increase of pore resistance and charge transfer resistance. At the Si(Cr+si) ratio of 20, the Si-bearing CrN possesses the best corrosion resistance due to the highest pore resistance and charge transfer resistance.

The CT values Comparisons for Antibiotic Resistant Bacteria and Resistant Genes by Chlorination (항생제 내성균 및 유전자제거를 위한 염소 CT 값 비교)

  • Oh, Jun-Sik;Kim, Sungpyo
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.269-274
    • /
    • 2014
  • The purpose of this study is to compare CT (disinfectant concentration * time) values in removing the antibiotic resistance bacteria, antibiotic resistance gene and transfer of antibiotic resistance genes. Different concentration of chlorine(C) and contact time(T) according to the removal of antibiotic resistance was calculated for each. As a result, for the 90% removal of antibiotic resistant bacteria, around 176~353 mg min/L CT values are needed. For the removal of the antibiotic resistance gene, 195~372 mg min/L CT values are required. For the 90% reduction of antibiotic resistance gene transfer by chlorine disinfection, 187~489 mg min/L CT values are needed. Based on our results, higher CT value was required for removing antibiotic resistant genes rather than antibiotic resistance bacteria.

Evaluation of Salt Damage Resistance of Concrete according to Fire Control Time (화재진압시간에 따른 콘크리트의 염해저항성 평가)

  • Lee, Jun-Hae;Park, Dong-cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.109-110
    • /
    • 2020
  • In the event of a fire, fire engines usually arrive within 15 minutes and become a fire suppressor. In this paper, an analytical model was established to evaluate the salt damage resistance of concrete according to fire suppression time, and the concentration of salt inside the concrete after fire was measured and the time to reach the critical concentration was assessed by how short.

  • PDF

A Study on the Fire Resistance of yLRC Composite Columns with Steel Sheet Forms and Angles (강재 영구거푸집을 사용한 yLRC 합성기둥의 내화성능 연구)

  • Kim, Bo Ram;Kang, Seong Deok;Kim, Hyung Geun;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.365-375
    • /
    • 2008
  • The main objective of this paper is to study the behaviour of yLRC composite columns at elevated temperatures by experimental test. The effects of load ratios, cross-section size and fire protection for the yLRC columns were investigate d by the test and compared using the heat transfer analysis perfo rmed based on the finite element program ANSYS 10.0 using the ISO834 standard fire curve, following the main guidelines proposed by the EC4 Part 1.2. As heat transfer is the movement of heat by conduction, convection, and radiation, and as temperature inside an object varies by position and time, time. As the steel's thermal conductivity is higher than that of concrete, steel loses its strength rapidly in a high-temperature situation such as a fire. Fire resistance performance of the yLRC composite column under fire conditions was evaluated througheat transfer analysis for parametric study.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.