• Title/Summary/Keyword: Transfer efficiency

Search Result 2,749, Processing Time 0.027 seconds

Numerical study of direct contact membrane distillation process: Effects of operating parameters on TPC and thermal efficiency

  • Zamaniasl, Mohammadmehdi
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.387-394
    • /
    • 2019
  • Membrane distillation (MD) is one of the water treatment processes which involves the momentum, heat and mass transfer through channels and membrane. In this study, CFD modeling has been used to simulate the heat and mass transfer in the direct contact membrane distillation (DCMD). Also, the effect of operating parameters on the water flux is investigated. The result shows a good agreement with the experimental result. Results indicated that, while feed temperature is increasing in the feed side, water flux improves in the permeate side. Since higher velocity leads to the higher mixing and turbulence in the feed channel, water flux rises due to this increase in the feed velocity. Moreover, results revealed that temperature polarization coefficient is rising as flow rate (velocity) increases and it is decreasing while the feed temperature increases. Lastly, the thermal efficiency of direct contact membrane distillation is defined, and results confirm that thermal efficiency improves while feed temperature increases. Also, flow rate increment results in enhancement of thermal efficiency.

Transfer of Calcium along Trophic Levels on Limestone and Granitic Gneiss Grassland (석회암과 화강편마암 지역의 초지에서 영양단계별 칼슘 전이)

  • Yi, Hoon-Bok;Nam, Sang-Ho;Kim, Joon-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.3
    • /
    • pp.228-238
    • /
    • 2007
  • Calcium plays an important role for the organisms' physiology, reproduction, and growth. Calcium amount and transfer efficiency along trophic levels were compared at two different geological areas, Limestone area (LS) and Granitic Gneiss area (GG) in 1992 and 1993. Biomass and calcium amount of plants, herbivores and carnivores were seasonally measured. The removal sweeping net method was used to collect the quantitative insect samples. Calcium content (mgCa $g^{-1}$ DM) and pH of soil were 4.85 and 7.3 at LS and 0.21 and 7.3 at GG. The calcium transfer efficiencies (%) at LS and CG were 0.2 and 4.2 from soil to plants, 0.002 and 0.02 from plants to herbivores, and 73 and 47 from herbivores to carnivores, respectively. As a whole, the high calcium content of the LS soil reduced the utilization of calcium by plants. The higher trophical levels were, the higher ecological efficiency of the biological levels was. The calcium transfer amount was higher at LS, but its efficiency was rather higher at GG.

Improvement of Electromagnetic Shielding Structure for Reduction of the Leakage Magnetic Field in WPT System (WPT 시스템의 누설자계 감소를 위한 전자파 차폐구조 개선)

  • Kim, Jongchan;Lee, Seungwoo;Kang, Byeong-Nam;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • In this paper, we propose an improved magnetic field shielding structure to reducing the magnetic field generated in the wireless power transfer system operating at a low frequency band. The proposed structure consists of the magnetic material and the conductive material, magnetic field cancelling effect for power transfer is minimized while improving the leakage magnetic field cancelling effect by optimizing the various design parameters in the proposed structure. We analyzed and verified the efficiency of the wireless power transfer system and the reduction effect of the leakage magnetic field through computer simulation and measurement. Analysis results show that power transfer efficiency of the wireless power transfer system utilizing the proposed structure is 77 %, which is maintained at the conventional power transfer efficiency. In addition, compared with the structure maintaining high power transfer efficiency, leakage magnetic field strength is reduced to 29~37 % at the nearest point.

Performance Enhancement Method Through Science DMZ Data Transfer Node Tuning Parameters (Science DMZ 데이터 전송 노드 튜닝 요소를 통한 성능 향상 방안)

  • Park, Jong Seon;Park, Jin Hyung;Kim, Seung Hae;Noh, Min Ki
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.2
    • /
    • pp.33-40
    • /
    • 2018
  • In an environment with a large network bandwidth, maximizing bandwidth utilization is an important issue to increase transmission efficiency. End-to-end transfer efficiency is significantly influenced by factors such as network, data transfer nodes, and intranet network security policies. Science DMZ is an innovative network architecture that maximizes transfer performance through optimal solution of these complex components. Among these, the data transfer node is a key factor that greatly affects the transfer performance depending on storage, network interface, operating system, and transfer application tool. However, tuning parameters constituting a data transfer node must be performed to provide high transfer efficiency. In this paper, we propose a method to enhance performance through tuning parameters of 100Gbps data transfer node. With experiment result, we confirmed that the transmission efficiency can be improved greatly in 100Gbps network environment through the tuning of Jumbo frame and CPU governor. The network performance test through Iperf showed improvement of 300% compared to the default state and NVMe SSD showed 140% performance improvement compared to hard disk.

HYDRAULIC ANALYSIS OF OXYGEN TRANSFER THROUGH AIR ENTRAINMENT IN RIPARIAN RIFFLES

  • Kim, Jin-Hong
    • Water Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.127-139
    • /
    • 2003
  • This paper presents the hydraulic analysis of the oxygen transfer through the air entrainment and the relationships between the efficiency of the oxygen transfer and the hydraulic parameters in the riparian riffles. Field survey on the pool-riffle formation of the river reach and the measurements of the oxygen transfer in the riffles were performed. Air entrainment occurred more frequently in the edged gravels rather than in the round and edgeless ones, and it was formed mainly from behind the trailing edges of the gravels. Oxygen transfer was found to be proportional to the flow velocity, the flow discharge, and the Froude number, but to be not closely related to the particle diameter. Average value of oxygen transfer in the riffles of study area was about 0.085, which shows good efficiency compared with results of smooth chute. Variation of the water level, which increases in proportion to the flow velocity and the flow discharge, seems to make the air entrainment more active, but has not been verified quantitatively. Relationships between the air entrainment and the variation of the water level must be considered in the further study.

  • PDF

Capacitive Coupling LLC Wireless Power Transfer Converter Through Glasses of Electric Vehicles (전기자동차의 유리를 통한 커패시티브 커플링 LLC 무선 전력 전송 컨버터)

  • You, Young-Soo;Yi, Kang-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.542-545
    • /
    • 2016
  • This work proposes a capacitive coupling-based wireless battery charging circuit that is built with vehicle glasses for electric vehicles. A capacitive coupling wireless power transfer offers many advantages, such as low metal impact and low energy transfer efficiency changes in accordance with changes in position. However, a large coupling capacitor is needed for high power transfer. Therefore, a new capacitive coupling-based wireless power transfer LLC resonant converter built with the glasses of an electric vehicle is proposed. The proposed converter is composed of coupling capacitors with glasses of an electric vehicle and two transformers for impedance transformation. The proposed LLC converter can transfer large power and obtain high efficiency with zero voltage switching. The validity and features of the proposed circuit is verified by experimental results with a 1.2 kW prototype.

On the Validity of the Effective Cavity Model with the Transfer Matrix Method as a Frame of Reference In VCSELs (수직 공진기 반도체 레이저에서 전달 행렬 방법과의 비교를 통한 유효 공진기 모델의 타당성 검토)

  • 김태용;김상배
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.7
    • /
    • pp.31-36
    • /
    • 2004
  • In comparison with in-plane lasers, predicting the output power and differential quantum efficiency of Vertical-Cavity Surface-Emitting Lasers(VCSELs) is very difficult due to the distributed Bragg reflector(DBR) layers. Therefore, effective cavity model and transfer matrix method have been adapted in order to calculate the output power and differential quantum efficiency The effective cavity model is inappropriate to calculate output power and differential quantum efficiency while it is practically adequate to calculate the threshold gain and threshold current density The reason is that the effective cavity model can not take account of the absorption in GaAs stack layer right below the metal aperture. In this paper, we have compared the threshold current and differential quantum efficiency calculated by using transfer matrix method with effective cavity model and we have made a study of the validity of the effective cavity model. Finally, we have confirmed the versatility of the transfer matrix method with these studies.

Implementation of Effective Wireless Power Transmission Circuit for Low Power System

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.846-849
    • /
    • 2018
  • Wireless power transfer (WPT) is the technology that enables the power to transmit electromagnetic field to an electrical load without the use of wires. There are two kinds of magnetic resonant coupling and inductive coupling ways transmitting from the source to the output load. Compared with microwave method for energy transfer over a long distance, the magnetic resonance method has the advantages of reducing the barrier of electromagnetic wave and enhancing the efficiency of power transmission. In this paper, the wireless power transfer circuit having a resonant frequency of 13.45 MHz for the low power system is studied, and the hardware implementation is accomplished to measure the power transmission efficiency for the distance between the transmitter and the receiver.

A Study on Charateristic of Modern Packing, 25mm NSW-ring, ppm by Absorption of NH3 gas (25mm NSW-ring, pp.를 충진한 충진탑에서 암모니아 흡수에 의한 유해가스 처리시 충진물의 특성연구)

  • 신은재;박진식
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.391-397
    • /
    • 1997
  • The study was carried out to demonstrate the superiority of used packing in view of energy saving and efficiency of mass transfer, comparing with conventional packing. The results are as follows : 1. Owing to low Pressure drop under high load. 25mm NSW-ring, pp. can cause energy saving 2. The unique magnitudes of used packing are as follows $C_G$=5.78, m=0.67, n=0.46 3. Used packing can make high efficiency including energy saving because of low pres sure drop per the number of transfer unit. To rate the characteristic of packing, It should be carried out that the measurement of pressure drop per packing height and per the number of transfer unfit. This study demonstrated the superiority of used packing by carring out above experiment and could be used as basic reference for design and predicting efficiency of packing tower which is tilled with same packing.

  • PDF

Effect of the Heat Transfer on the Performance Characteristics of Rolling Piston Type Rotary Compressors for Air Conditioner (회전 피스톤형 로터리 압축기 내의 열전달이 성능특성에 미치는 영향에 관한 연구)

  • 양동준;정진택;박진무;황선웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.763-770
    • /
    • 2001
  • The high pressure side rotary compressor is investigated in this study. The temperatures at 29 points of main components and the refrigerant and the performance of the instrumented compressor are measured at various operating conditions. The complex heat transfer mechanism between the components, such s cylinder, suction pipe and stator of motor, is fairly clarified. It is also confirmed that the achievement of a high efficiency by reducing the heat transfer loss in the rotary compressor is possible.

  • PDF