• 제목/요약/키워드: Transfer device

검색결과 1,122건 처리시간 0.026초

압전 액츄에이터를 이용한 열전냉각 시스템 성능 향상에 관한 연구 (A Study on Enhancement of Thermoelectric Cooling System Performance by Piezoelectric Actuator)

  • 양호동;윤희성;오율권
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.13-19
    • /
    • 2009
  • The thermoelectric cooling system consisted of the thermoelectric module, a heat sink and a cooling fan, respectively. Also, the piezoelectric actuator was applied to improve the performance of thermoelectric cooling system and investigate the heat transfer phenomenon. The temperature distribution of test section was measured to investigate cooling characteristics of thermoelectric cooling system. The flow phenomenon of test section was visualized using visualization device. When the piezoelectric actuator was applied to the heat transfer process of thermoelectric cooling system, acoustic streaming was occurred in test section. The acoustic streaming was occurred forced convection flow, and was regularly formed the temperature distribution in test section. The results clearly show that the acoustic streaming is one of the prime effects to enhance the convection heat transfer and can enhance the performance of thermoelectric cooling system.

TCSC 투입계통의 송전용량 증대에 대한 연구 (The Effect of Thyristor Controlled Series Capacitor(TCSC) on Power Transfer Capability)

  • 이주호;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.890-892
    • /
    • 1998
  • TCSC is a FACTS device that can control the active power flow and current of transmission lines by adjusting line impedances. In this paper, we study the effect of TCSC on power transfer capability. A static model of TCSC is implemented in the continuation power-flow(CPF) Program and the power transfer capability is measured using the CPF. The site of TCSC is selected to increase power transfer capability by the sensitivity information provided from the CPF. The effect of TCSC with various control mode is tested in IEEE New England 30-bus system.

  • PDF

폴리이미드 유기초박막의 유전특성에 관한 연구 (A study on the Dielectric Characteristics of Polyimide Organic Ultra Thin Films)

  • 전동규;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1744-1746
    • /
    • 1999
  • In this paper, we give pressure stimulation into organic ultra thin films and detected the induced displacement current properties, and then manufacture a device under the accumulation condition. In processing of a device manufacture, we can see the process is good from the change of a surface pressure and transfer ratio of area per molecule of organic ultra thin films. The structure of manufactured device is MIM(Au/polyimide LB films/AU), the number of accumulated 19 layers. I-V characteristic of the device is measured from -5[V] to +5[V]. The maximum value of measured current is increased as the number of accumulated layers are decreased. The insulation of a thin film is better as the interval between electrodes is larger, and the insulation properties of a thin film is better as the distance between electrodes is larger.

  • PDF

A Thermal Model for Electrothermal Simulation of Power Modules

  • Meng, Jinlei;Wen, Xuhui;Zhong, Yulin;Qiu, Zhijie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.441-446
    • /
    • 2013
  • A thermal model of power modules based on the physical dimension and thermal properties is proposed in this paper. The heat path in the power module is considered as a one-dimensional heat transfer in the model. The method of the parameters extraction for the model is given in the paper. With high speed and accuracy, the thermal model is suit for electrothermal simulation. The proposed model is verified by experimental results.

Walking Pattern Analysis Using an Acceleration Sensor Device

  • Hong, Ju-Hee;Han, Kap-Soo;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.396-401
    • /
    • 2017
  • In this paper, a device to analyze gait pattern was developed by using a 2-axis acceleration sensor attached to the foot. The 1st low-pass filter was adapted to limit the frequency band up to 5 Hz. An algorithm to detect the peak value exceeding the threshold voltage of an X-axis acceleration sensor and a Z-axis acceleration sensor was developed and normal and abnormal walking patterns were thus differentiated. Also, MCU and Bluetooth were combined to transfer the data to other MCUs to display on an LCD; the size of the device could then be reduced. The new algorithm and the device allowed the individual walking patterns to be easily measured at a low cost and with less restriction on activities compared to conventional multiple pressure sensors or motion camera system.

LB법으로 제작한 Arachidic Acid 다층막의 누적전이와 전기특성 (Deposition Transfer and Electrical Properties of Arachidic Acid Multilayer Manufacture by LB Method)

  • 송진원;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.11-14
    • /
    • 2001
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 30[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto slide glass as Y-type film. The physicochemical properties of the LB films were examined by UV absorption spectrum, SEM and AFM. The structure of manufactured device is Au/arachidic acid/Al. the number of accumulated layers are 3~9. Also. we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

Electroluminescence of a red fluorescent dye doped in an $Alq_{3}$:rubrene Mixed Host

  • Kang, Hee-Young;kang, Gi-Wook;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.948-951
    • /
    • 2003
  • The electroluminescence (EL) properties were studied in organic light-emitting diodes with a red fluorescent dye, 4- (dicyanomethylene)- 2- tert-butyl-6 (1,1,7,7-tetramethyljulolidyl-9-enyl)- 4H- pyran (DCJTB) doped into tris-(8-hydroxyquinoline)aluminum ($Alq_{3}$), rubrene and the mixed matrix of $Alq_3$ and rubrene. The device with DCJTB doped into the $Alq_{3}$:rubrene mixed host shows an efficient red emission from DCJTB with a negligible EL emission from $Alq_{3}$ and a lower EL onset voltage compared to the device with DCJTB doped into the $Alq_{3}$ only host. The quantum efficiency is almost temperature-independent for the device with the $Alq_3:rubrene$ mixed host. The results indicate that recombination of injected electrons and holes occurs on rubrene and subsequent energy transfer to DCJTB dominates in the device with the $Alq_{3}$:rubrene mixed host.

  • PDF

현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 - (Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 -)

  • 김선칠
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

UPnP 브리지를 위한 범용 MFD 구조 (General MFD Structure for UPnP Bridge)

  • 최용순;강정석;박홍성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.289-290
    • /
    • 2007
  • UPnP Bridge supporting diverse network interface has to meet standard requirements in order to be connected with legacy devices. It is able to provide or bridge a service description and device description according to a specification because IEEE1394 and USB have this standard requirements. But it is difficult to know whether it RS232C supports only serial communication and packet transfer. It need a document for the standard definition of communication protocol on UPnP device having such interface. By doing so, this document can understand device and packet type. This paper defines MFD(Message Field Description) and makes UPnP message converter. So it will be base to standardize supporting variable legacy device.

  • PDF