• 제목/요약/키워드: Transfer Function Analysis

검색결과 1,034건 처리시간 0.027초

Order identification of transfer function-noise model

  • Park, Seongju;Bae, Hankyung;Huh, Kyungmoo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.164-169
    • /
    • 1992
  • Classical methods for estimating transfer function models have not always been successful. A statistic approach to the identification of transfer function models which is corrupted by disturbances or noise is presented. The estimated impulse response is obtained from the autocorrelation function and cross correlation function between the measured input and output. Several data analysis tools such as R- , S- and GPAC array for the estimated impulse response give us pretty clear information on the order of transfer function models.

  • PDF

Modeling of a Transfer Function for Frequency Controlled Resonant Inverters

  • Han, Mu-Ho;Lee, Chi-Hwan;Kwon, Woo-Hyun
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.567-574
    • /
    • 2009
  • A linear transfer function for the output current control of frequency-controlled resonant inverters is proposed in this paper. The circuit of resonant inverters can be transformed into two coupled circuits through the complex phasor transform. The circuits consist of cross-coupled power sources and passive elements. The circuits are used to induce the state space equation, which is transformed into the $4^{th}$ order cross-coupled transfer function. The $4^{th}$ order cross-coupled transfer function is modeled into a $2^{nd}$ order linear transfer function based on a behavior analysis of the pole and zero locations that facilitate a simple and intuitive linear transfer function. The feasibility and validity of the proposed linear transfer function were verified by simulation and experiment.

금속벨트 CVT의 전달함수 도출과 변속비 LQG/LTR 제어 (Transfer Function Derivation and LQG/LTR Speed Ratio Control for a Metal Belt CVT)

  • 김종준;송한림;김현수
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.49-58
    • /
    • 1997
  • In this paper, a transfer function was obtained for a PWM high speed solenoid valve controlled metal belt CVT system. The transfer function was defined as the ratio of speed ratio to PWM duty ratio and derived in time domain by linear regression analysis from the experimental results. The transfer function obtained showed different dynamic characteristics for the up and down shift. Also, LQG/LTR controller was designed for the CVT system using the transfer function. It is seen from the experimental results that LQG/LTR control showed good performance for the speed ratio tracking and disturbance rejection. The phase difference and relatively slow response are considered due to the inaccuracy os the transfer functions, which resulted from the inherent nonlinearities of the transmission characteristics of the metal belt CVT.

  • PDF

진동지속시간을 고려한 고속철도교량의 진동 사용성 처짐 한계 (Deflection Limit on Vibration Serviceability of High-speed Railway Bridges Considering the Exposed Time Duration)

  • 전법규;김남식;김성일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1444-1451
    • /
    • 2010
  • This paper aims for proposed the deflection limit on vibration serviceability of high-speed railway bridges considering the exposed time duration when a train passes a railway bridge. For this purpose, bridge-train transfer function was derived and bridge-train interaction analysis was performed by using the derived function. The vertical acceleration signals of passenger cars obtained from bridge-train interaction analysis were compared with them from the bridge-train transfer function by moving constant force analysis. Therefore it was estimated possible to induce the comfort deflection limit of railway bridge by using bridge-train transfer function. The deflections by moving force of single span bridge and continuous bridge were assumed as sine and haversine wave. The deflection limit on vibration serviceability of high-speed railway bridges considering the exposed time duration can be expanded using bridge-train transfer function and bridge comfort limit considering serviceability due to bridge vibration. And it was compared to other allowable deflection limits of railway bridge design specifications.

  • PDF

전달함수를 이용한 유정압테이블 운동정밀도 해석법의 제안 및 이론적 검증

  • 오윤진;박천홍;이후상;홍준희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.9-14
    • /
    • 2001
  • A new model utilizing a transfer function is introduced in the present paper for analizing motion errors of hydrostatic tables. Relationship between film reaction force in a single hydrostatic pad and form error of a guide rail is derived at various spacial frequencies by finite element analysis, and it is expressed as a transfer function. This transfer function clarifies so called averaging effect of the oil film quantitively. For example, it is found that the amplitide of the film reaction force is reduced as the spacial frequency increases or relative width of the pocket is reduced. Motion errors of a multiple pad table is estimated from transfer function, geometric relationship between each pads and form errors of a guide rail, which is named as Transfer Function Method. Calculated motion errors by TFM show good agreement with motion errors calculated by Multi Pad Method, which is considered entire table as an analysis object. From the results, it is confirmed that the proposed TFM is very effective to analyze the motion errors of hydrostatic tables.

  • PDF

메이슨의 공식을 이용한 본드그래프의 전달함수 유도법에 관한 연구 (A Study on the Induction Method of Transfer Function of Bond Graph using Mason's Rule)

  • 한창수;오재응
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.66-75
    • /
    • 1998
  • In many case of optimal design and sensitivity analysis, obtaining of transfer function between input and output variables is a difficult and time-consuming problem. The bond graph modeling is a method that is used for making it easy to analyze complex systems composed of mechanical and electrical parts. It gives us a simple and systematic tool to get state-space equations easily. And we can obtain the transfer function graphically using bond graph and Mason's rule. This paper shows how bond graphs are converted to block diagram and how Mason's rule is applied. And the simple direct method to obtain transfer function from bond graph is introduced. As a example, induction of transfer function of electric power steering composed of mechanical and electrical parts will be done.

  • PDF

파워트레인에 의한 차량 실내 소음 특성 및 전달 함수 측정 (The Analysis of Vehicle Interior Noise by the Powertrain, and Measurement of Noise Trasnsfer Function using Vibro-Acoustic Reciprocity)

  • 김성종;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.501-506
    • /
    • 2007
  • Structure-borne noise is the interior noise that results from the low frequency vibrational energy transmitted through those body and joint parts. The relation between the excitation of powertrain and resultant interior sound must be analyzed in order to identify and predict the structure borne noise. The method of acoustic source excitation is preferred than the method of mechanical force excitation to measure the NTF(noise transfer function). Because acoustical method is more convenient and reliable. In this paper, to analysis and identify vehicle interior noise by powertrain is performed, and the vibro-acoustic transfer function is extracted from experimental measurement. These are important step of TPA(transfer path analysis) to identify effect of interior noise resulted from powertrain running excitation.

  • PDF

부분기여도함수를 이용한 전술차량 소음원 분석 (Noise-source Analysis of Tactical Vehicle Using Partial Coherence Function)

  • 박성호;이경현;한형석;전수홍
    • 한국소음진동공학회논문집
    • /
    • 제26권7호
    • /
    • pp.774-780
    • /
    • 2016
  • In this paper noise source and transfer path of tactical vehicle are analyzed with partial coherence function and spectrum analysis. Engine, transmission, structure panel and aerodynamic are main source of cabin noise. To reduce cabin noise, identifying transfer path of sources and analyzing their contribution is important. With modeling of transfer path and partial coherence function, transfer path and principal noise source can be identified. Engine/transmission and structural resonance are principal source of low frequency noise and by adding stiffener and sound absorbing material, resonance of vibration and inflow air problem can be solved.

보드 설계에 따른 Adaptive Bandwidth PLL의 성능 분석 (Performance Analysis of Adaptive Bandwidth PLL According to Board Design)

  • 손영상;위재경
    • 대한전자공학회논문지SD
    • /
    • 제45권4호
    • /
    • pp.146-153
    • /
    • 2008
  • High speed serial link에 적합한 clock multiphase generator용 integrated phase-locked loop (PLL)을 설계하였다. 설계된 PLL은 programmable current mirror를 사용하여 동작 범위 안에서 동일한 loop bandwidth와 damping factor를 가진다. 또한 설계한 PLL 회로 netlists를 가지고 HSPICE 시뮬레이션을 통해 close-loop transfer function과 VCO의 phase noise transfer function을 구하였다. Board 위 칩의 자체 임피던스는 decoupling capacitor의 크기와 위치에 따라 계산된다. 세부적으로, close-loop transfer function에서 gain의 최대값과 VCO noise transfer function에서 gain의 최대값 사이의 주파수범위에서 decoupling capacitor의 크기와 위치에 따른 보드 위 칩의 자체 임피던스를 구하였다. 이를 바탕으로 보드에서의 decoupling capacitor의 크기와 위치가 PLL의 jitter에 어떠한 영향을 미치는지 분석하였다. 설계된 PLL은 1.8V의 동작 전압에서 400MHz에서 2GH의 wide operation range를 가지며 $0.18-{\mu}m$ EMOS공정으로 설계하였다. Reference clock은 100MHz이며 전체 PLL power consumption은 1.2GHz에서 17.28 mW이다.

Transfer Function 모형을 이용한 수도물 수요의 단기예측 (A Short-term Forecasting of Water Supply Demands by the Transfer Function Model)

  • 이재준
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.88-103
    • /
    • 1996
  • The objective of this study is to develop stochastic and deterministic models which could be used to synthesize water application time series. Adaptive models using mulitivariate ARIMA(Transfer Function Model) are developed for daily urban water use forecasting. The model considers several variables on which water demands is dependent. The dynamic response of water demands to several factors(e.g. weekday, average temperature, minimum temperature, maximum temperature, humidity, cloudiness, rainfall) are characterized in the model by transfer functions. Daily water use data of Kumi city in 1992 are employed for model parameter estimation. Meteorological data of Seonsan station are utilized to input variables because Kumi has no records about the meteorological factor data.To determine the main factors influencing water use, autocorrelogram and cross correlogram analysis are performed. Through the identification, parameter estimation, and diagnostic checking of tentative model, final transfer function models by each month are established. The simulation output by transfer function models are compared to a historical data and shows the good agreement.

  • PDF