• 제목/요약/키워드: Transfer Capability

검색결과 599건 처리시간 0.147초

유통제조 기업의 해외 자회사 지식이전에서 기술특유성의 조절효과 (The Moderating Effects of Specificity of Technology in the Knowledge Transfer of Distributive Manufacturing MNEs)

  • 조연성
    • 유통과학연구
    • /
    • 제14권9호
    • /
    • pp.121-132
    • /
    • 2016
  • Purpose - This study has the following objectives. First, it seeks to build an integrated model that can analyze the path through which headquarters, subsidiary competence, and knowledge transfer performance influence subsidiary performance. Second, it analyzes the influence of the specificity of technology as a moderating effect factor on knowledge transfer process. Third, it will conduct an empirical analysis on distributive manufacturing MNEs and suggests an implication for companies that actually need technological localization. The difference of this study are as follows. First, unlike the existing studies, this study can expand a theoretical discussion as it uses subsidiary performance as the dependent variable. Second, it sets the specificity of technology as a moderating effect factor, not an antecedent, and can draw a theoretical implication. Research design, data, and methodology - This study built a path analysis model to identify the influence of the disseminative capacity and absorptive capacity of distributive manufacturing MNEs on subsidiary performance. Based on the previous studies, it set 19 items as 5 latent variables, and established 6 hypotheses by including the moderating effect of the specificity of technology between them. The final 203 companies were selected as analysis samples through a survey questionnaire. For empirical analysis, the study used PLS (Partial Least Square) that is based on structural equation model. Results - The empirical analysis result demonstrated that both headquarters' disseminative capability and subsidiaries absorptive capacity had a positive influence on knowledge transfer performance. Knowledge transfer performance also had a positive influence on subsidiary performance. In the analysis of moderating effect, the specificity of technology acted as a significant moderating variable only between knowledge transfer performance and subsidiary performance; it did not show a statistically significant moderating effect among disseminative capability, absorptive capacity, and knowledge transfer performance. Conclusions - The empirical analysis results of this study demonstrate the importance of disseminative capability and absorptive capacity in knowledge transfer to subsidiaries from the distributive manufacturing MNEs in Korea. The analysis on the moderating effect indicates that the specificity of technology in Korean companies influences on the process of making achievement by using the transferred knowledge.

가용 송전 능력(Available Transfer Capability : ATC)의 증대 방안에 대한 연구 (Study for Increment Method of ATC (Available Transfer Capability))

  • 이영호;백영식;송경빈;추진부;원종률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.55-57
    • /
    • 2001
  • In this paper, algorithm for increment of ATC is proposed. ATC of the power transfer system is determined by the smallest ATC among transmission lines' in the power transfer system. So power flow of that transmission line shall be decreased to increase ATC, using the redistribution of each generation power with liner programing method. By the studying example case, $10\sim20%$ increment of ATC is confirmed in the power transfer system.

  • PDF

CO2 배출량을 고려한 가용송전용량 계산에 관한 연구 (Available Transfer Capability Evaluation Considering CO2 Emissions Using Multi-Objective Particle Swarm Optimization)

  • 천이경;김문겸;류재근;박종근
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1017-1024
    • /
    • 2010
  • Under the Kyoto Protocol many countries have been requested to participate in emissions trading with the assigned $CO_2$ emissions. In this environment, it is inevitable to change the system and market operation in deregulated power systems, and then ensuring safety margin is becoming more important for balancing system security, economy and $CO_2$ emissions. Nowadays, available transfer capability (ATC) is a key index of the remaining capability of a transmission system for future transactions. This paper presents a novel approach to the ATC evaluation with $CO_2$ emissions using multi-objective particle swarm optimization (MOPSO) technique. This technique evolves a multi-objective version of PSO by proposing redefinition of global best and local best individuals in multi-objective optimization domain. The optimal power flow (OPF) method using MOPSO is suggested to solve multi-objective functions including fuel cost and $CO_2$ emissions simultaneously. To show its efficiency and effectiveness, the results of the proposed method is comprehensively realized by a comparison with the ATC which is not including $CO_2$ emissions for the IEEE 30-bus system, and is found to be quite promising.

전압 안정도 제약계통에 대한 고온초전도 케이블 적용효과 (Effects of HTS Cable Applied to the Voltage Stability Limited Power System)

  • 이근준;황시돌
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.169-173
    • /
    • 2004
  • 본 논문은 전력계통의 전압 안정도 제약 문제를 해결하는데 고온 초전도 케이블을 적용하기 위한 기법을 제시하였다. 대전력계통의 유효 송전용량은 종종 전압 안정도 제약에 의해 결정된다. 기존의 초전도 케이블 응용 연구는 주로 도심지역의 고밀도 전력 수송 문제를 해결하는 대안으로 연구의 초점을 두어왔지만, 고온 초전도 케이블의 선로정수 개선효과를 이용하면 전압 안정도로 제약된 계통의 송전용량을 증가시킬 수 있어 그 응용 범위가 확대될 수 있다. 전압 안정도에 의한 최대 수송전력을 결정하는 데는 IPLAN에 의한 P-V곡선을 이용하였고, 대체 대상선로는 부하 증가시 무효전력 손실감도가 가장 큰 선로로 하였다. 결과의 타당성을 검증하기 위해 IEEE 14모선 계통을 사용하였으며, 적용결과 Case II는 70[%], Case III에서는 160[%]의 추가 수송 능력 증가를 가져올 수 있었다.

HFC 망에서의 고속 멀티미디어 전송시스템 개발 (Development of High Speed Multimedia Transmission System based on HFC Network)

  • 손병희;남의석;양효식
    • 융합신호처리학회논문지
    • /
    • 제12권2호
    • /
    • pp.102-106
    • /
    • 2011
  • Hybrid Fiber Coax (HFC) network의 전송 능력은 xDSL과 비교하여 우수하지만, HFC network에서 아직도 케이블 모뎀을 사용하기 때문에 고화질의 영상을 전송할 때는 속도가 느려진다. 본 논문에서는 HFC망에서 사용하는 케이블 모뎀의 성능을 개선하기 위해서 개발된 하향 전용 IP-cable sender와 IP-cable modem을 제시하였다. 개발된 시스템은 HFC 망에서 30 Mbps 급의 IP 방송을 지원하고, 21 Mbps 속도의 고화질 트랜스포트 스트림을 사용하여 장시간 고화질 서비스를 제공한다.

선형계획법을 이용한 총송전용량 평가 (Assessment of Total Transfer Capability using Linear Programming)

  • 김규호;송경빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.262-263
    • /
    • 2006
  • This paper presents a scheme to solve the congestion problem with phase-shifting transformer(PST) and power generation using linear programming method. A good design of PST and power generation control can improve total transfer capability(TTC) in interconnected systems. This paper deals with an application of optimization technique for TTC calculation. linear programming method is used to maximize power flow of tie line subject to security constraints such as voltage magnitude and real power flow. The proposed method is applied to 10 machines 39 buses model systems to show its effectiveness.

  • PDF

Saturated Boiling Heat Transfer of Freon-113 in Hemispherical Narrow Space and Implications for Degraded Core Coolability in Reactor Vessel Lower Plenum

  • Bang, Kwang-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.574-579
    • /
    • 1995
  • Saturated boiling heat transfer experiment in a hemispherical narrow space is conducted using Freon-113 to investigate an additional heat removal capability through a hypothetical gap between lower head and degraded core. The narrow space of 1mm consists of a 124mm diameter heated stainless steel hemisphere and a glass outer vessel. Within the hemispherical narrow space large coalesced bubbles are produced and these bubbles rise in random direction, causing liquid flow in from the opposite side to fill the region. Such flow in random direction makes the flow field in the narrow space very chaotic and thus enhance heat transfer. The heat transfer coefficient is higher at lower angle and at higher heat flux. The present study shows that the liquid from upper region can effectively penetrate into the gap and augment the heat removal capability through tile gap.

  • PDF

암호화와 DnCNN을 활용한 문서 복원능력 향상에 관한 연구 (An Enhancement Method of Document Restoration Capability using Encryption and DnCNN)

  • 장현희;하성재;조기환
    • 사물인터넷융복합논문지
    • /
    • 제8권2호
    • /
    • pp.79-84
    • /
    • 2022
  • 본 논문은 문서의 보안과 손실 및 오염에 대하여 복원능력을 향상시키는 방안을 제안한다. 이를 위해서 암호화로 DnCNN(DeNoise Convolution Neural Network)을 제시한다. 암호화 방법을 구현하기 위하여 2D이미지정보를 광학에 사용되는 공간주파수 전달함수(Spatial Frequency Transfer Function)의 수학적 모델을 적용한다. 공간 주파수 전달함수를 사용하여 광학적 간섭 패턴을 암호화로 사용하고 공간 주파수 전달함수의 수학적 변수를 복호화하는 암호로 사용하는 방법을 제안하였다. 또한, 딥러닝을 적용한 DnCNN 방법을 적용하여 노이즈 제거하여 복원 성능을 개선한다. 실험결과, 65%의 정보 손실이 있는 경우에도 Pre-Training DnCNN Deep Learning을 적용한 결과 공간 주파수 전달함수만을 활용한 복원 결과 와 비교하여 PSNR(Peak Signal-to-noise ratio)을 11% 이상 우수한 성능을 확인할 수 있다. 또한, CC(Correlation Coefficient)의 특성도 16% 이상 우수한 결과를 보이고 있다.

LiBr계 용액을 사용한 수직관 흡수기의 열 및 물질 전달에 관한 연구 (A Study on Heat and Mass Transfer in a Vertical Tube Absorber Using LiBr Family Solutions)

  • 조현철;김종보;정시영;강상우;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.196-206
    • /
    • 1995
  • Experimental investigations on heat and mass transfer characteristics in a vertical tube absorber have been carried out. Three different copper tubes with a length of 1.5m have been tested using LiBr solution and LiBr-$CaCl_2$ solution. The effects of solution flow rate, cooling water temperature, solution inlet temperature and evaporation temperature have been investigated in detail. It is found that heat transfer coefficient increases gradually with the increase of solution flow rate, but decreases rapidly for the flow rates less than 0.02kg/ms. The grooved tube generally shows better heat transfer performances than the smooth tube. LiBr solution shows almost no absorption capability for the cooling water temperatures over $40^{\circ}C$. LiBr-$CaCl_2$ gives less decreasing rate in absorption capability at these temperatures and the heat transfer coefficient becomes less dependent on the types of tubes in use. Considering heat and mass transfer rates, LiBr-$CaCl_2$ solution is found to be more suitable than LiBr solution for air cooled absorber, which operates at higher temperature than water cooled absorber.

  • PDF

경사진 원형관에서의 공냉응축에 관한 실험적 연구 (Experimental Study of Air-cooled Condensation in Slightly Inclined Circular Tube)

  • 김동억;권태순;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권4호
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, the experimental investigation of air-cooled condensation in slightly inclined circular tubes with and without fins has been conducted. In order to assess the effects of the essential parameters, variable air velocities and steam mass flow rates were given to the test section. The heat transfer performance of air-cooled condensation were dominantly affected by the air velocity, however, the increase of the steam mass flow rate gave relatively weaker effects to total heat transfer capability. And in the experimental cases with the finned tube, the total heat transfer rate of the finned tube was significantly larger than that of the flat tube. From those results, it can be confirmed that the most important parameter for air-cooled condensation heat transfer is the convective heat transfer characteristics of air. Therefore, for the well-designed long-term cooling passive safety system, the consideration of the optimal design of the fin geometry is needed, and the experimental and numerical validations of the heat transfer capability of the finned tube would be required.