• 제목/요약/키워드: Trans tibial Amputees

검색결과 8건 처리시간 0.021초

인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향 (Effect of Foot Eversion on Knee and Ankle of Trans-tibial Amputees)

  • 배태수;장윤희;김신기;문무성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1505-1508
    • /
    • 2008
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

  • PDF

하퇴의지착용자에 대한 인공족관절 유형(고정형, 단축형, 다축형)에 따른 지면반발력 및 에너지 소모의 측정 (Measurement of Ground Reaction Force and Energy Consumption for Ankle Assembly (Fixed-axis , Single-axis , Multi-axis Type) of Trans-Tibial Amputee)

  • 김성민;배하석;박창일
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권6호
    • /
    • pp.543-550
    • /
    • 2001
  • 본 연구에서는 하퇴 절단환자에서 고정형. 단축형, 다축형 인공족관절 장착시 지면반발력과 에너지 소비량을 측정하여 하퇴의지에 대한 생체역학적 평가를 하였다. 실험에는 각각 2명의 남성과 여성 하퇴 절단 환자가 3종류의 의지를 착용하고 참여하였으며. 3차원 보행분석은 7개의 기준점에 대하여 전체 입각기에 대한 지면 반발력의 체중에 대한 비율로 나타내었다. 하퇴의지 에너지 소비량은 피 실험자들이 각각 2km/h, 3km/h 그리고 가장 걷기 편한 속도로 런닝머신 위에서 보행하게 하면서 측정하였다 실험결과는 지면반발력에서 다축형 인공족관절 장착시 추진력과 후진력의 보행특성에 대하여 우위를 보이며, 고정형 인공족관절 장착시에는 보행균형과 무게중심의 이동에 대해 상대적인 우위를 보였다. 에너지 소비량은 2.3km/h 이상의 보행속도에서 단축형 인공족관절 장착시 다른 두 의지에 비해 적은량의 에너지 소비를 보였다.

  • PDF

하퇴절단자용 단축식 발과 스포츠용 에너지 저장형 발 보행 특성 비교연구 (A Comparative Study of Gait Characteristics between Single Axis Foot and Energy Storing Foot for Sports in Trans-tibial Amputee)

  • 장윤희;배태수;김신기;문무성
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.126-132
    • /
    • 2009
  • This study examined the differences in spatio-temporal parameters, joint angle, ground reaction force (GRF), and joint power according to the changes of gait speed for trans-tibial amputees to investigate the features of the energy-storing foot for sports. The subjects walked at normal speed and at fast speed, wearing a single-axis type foot (Korec) and an energy-storing foot for sports (Renegade) respectively. The results showed that Renegade yielded faster gait speed as well as more symmetric gait pattern, compared to Korec. However, as gait speed was increased, there was no significant difference in kinematics, ground reaction force, and joint power between two artificial foots. This was similar to the results from previous studies regarding the energy-storing foot, where the walking velocity and gait symmetry have been improved. Nevertheless, the result of this study differed from the previous ones which reported that joint angle, joint power, and GRF increased as the gait speed increased except spatio-temporal parameters.

인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향 (Effect of Eversion Characteristics on Knee and Ankle Joint of Trans-tibial Amputees)

  • 배태수;장윤희;김신기;문무성
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.886-891
    • /
    • 2009
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • 한국전문물리치료학회지
    • /
    • 제13권4호
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

힘측정판과 레이저 광을 이용한 정적 의족정렬장치의 개발 (Development of a Static Prosthesis-Alignment Device Using a Force Plate and a Laser Light)

  • 이기원;김기완;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.385-390
    • /
    • 2000
  • 의족착용자의 보행에 있어서 의족의 정렬은 매우 중요하나, 정량적이고 다양한 의족에 공통적으로 적용할 수 있는 정렬방법이 아직 소개되지 않고 있다. 본 연구를 통해서 load cell, 레이저, 이송 가이드로 구성되는 정적 의족정렬시스템을 개발되었다. 개발된 시스템을 24명의 남자성인과 4명의 하퇴의족착용자에게 적용하여 직립자세와 전방, 후방ㅇ로 기운 자세에서 족관절, 슬관절, 대전자, 어깨관절등과 하중선과의 상대적 위치를 측정하였다. 정상인의 중립자세에서 하중선의 위치는 외과, 슬관절, 견관절에서는 앞쪽에 그러나 대전자에서는 뒤쪽에 있었다. 정상인이 앞쪽으로 최대한 기운 자세에서 외과와 슬관절, 대전자는 하중선의 뒤쪽에 위치하였으나 견관절은 앞쪽에 위치하였다. 그러나 뒤쪽으로 기운 자세의 경우, 하중선은 견관절을 제외한 모든 곳의 뒤쪽에 위치하였다. 의족착용자의 환측의 하중선은 족관절, 슬관절, 대전자, 견관절 모두의 전방에 위치하였으며, 의족착용자의 건측에서의 하중선의 위치는 정상인의 경우와 통계적으로 유사하였다. 본 연구를 통해서 개발된 정적 의족정렬시스템은 의족 착용자는 물론, 정상인들의 하중선과 주요 관절과의 상대적 위치를 파악하는데 매우 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF

하퇴의지 착용자와 정상성인 보행간의 시간-거리 및 운동형상학 변수 분석 (Analysis of Time-Distance and Kinematic Gait Parameters Between Unilateral Trans-Tibial Amputees and Healthy Subjects)

  • 강필;김장환;최흥식;신헌석
    • 한국전문물리치료학회지
    • /
    • 제9권4호
    • /
    • pp.61-68
    • /
    • 2002
  • 본 연구는 하퇴의지 착용자와 정상 성인간의 시간-거리, 운동형상학 변수를 조사하고 비교하기 위하여 실시하였다. 연구 대상자는 외상으로 인한 하퇴 절단자로서 내골격식 하퇴의지를 착용하고 독립적으로 보행이 가능한 20명과 연령, 신장으로 짝짓기한 대조군(matched control group) 20명이 참여하였다. 보행분석은 Vicon Clinical Manager Software (VCM)를 내장한 PC에 5개의 카메라가 연결되어 있는 Vicon 512 Motion Analysis System (MAS, Oxford Metrics Inc.)을 이용하였다. 하퇴의지 착용군의 단하지 지지시간이 정상 성인군에 비해 유의하게 짧았으며(p<.05), 하퇴의지 착용군에서 슬관절의 선전이 증가되었으며 족관절의 저측굴곡이 감소되었다(p<.05). 하퇴절단자들의 보행개선을 위해서는 하퇴절단자 개인의 보행능력에 알맞은 부품의 선택, 체계적인 보행훈련 및 평가, 보행능력 향상을 위한 근력강화 프로그램 등 체계적인 재활훈련 프로그램이 필요한 것으로 사료된다. 본 연구는 연구대상자의 수가 제한되어 있으므로 연구의 결과를 일반화하기에는 제한점이 있으나, 향후 편측 하퇴절단자의 보행연구에 대한 기초 자료로 사용될 수 있을 것이라고 생각된다.

  • PDF