• 제목/요약/키워드: Traction System

검색결과 700건 처리시간 0.031초

귀선전류의 불평형에 따른 차상신호에 미치는 영향에 관한 연구 (A Study on the Effect of Cab Signal through Unbalance of the Traction Return Current)

  • 이태훈;박기범;성순욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1694-1700
    • /
    • 2007
  • In the electrified section, both of return current and signal current are flowing in the same rail in common. But signal current shall be allowed to flow in the specific track circuit and not in the other circuit while the traction return current shall come back to power sub-station. This paper presents measuring system that use both sensor and antenna. The aim of the system is to achieve the difference in current between the two rails and the presence of trimming capacitors. In order to improve the transmission level, trimming capacitors are connected between the two rails at constant spacing. To maintain the balance of traction return current, rails of both sides may be jointed by the so-called SVPMM. The traction return current is sometimes unbalanced owing to the ill-contact of SVPMM. In this paper, we propose a diagnosis method based on a short-circuited current(Icc), trimming capacitors and traction return current measured by Korail inspection vehicles. Whether Icc is good or bad depends not only on the presence of trimming capacitors but also on the unbalance of the traction return current.

  • PDF

Halbach magnet array 구조를 이용한 철도차량용 구동 전동기의 출력밀도 향상 설계 방법 (Output Density Increasing Design for Railway Vehicle Traction Motor using Halbach Magnet Array Structure)

  • 이기덕;전현우;이주;이형우
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1732-1736
    • /
    • 2014
  • Generally, traction motors for railway vehicles are inferior to that of electric vehicle in terms of output density. Traction motors for railway vehicles are relatively free of spatial constraints than motors electric vehicles, but in terms of whole system efficiency, increasing output density of traction motor is helpful. In this paper, using Halbach magnet array structure, output density of traction motor for 40kW class tram was elevated. This paper introduce detailed design process of the Halbach magnet array structure applied model, and check the affects on output characteristics by parameters like rotor shape, airgap diameter and pole ratio. Also, electrical output characteristics were compared between typical SPMSM model and Halbach magnet array model, which has same output size.

전기철도 전원계통에서의 화재 사고사례 분석 (Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;김진표;박남규;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

MULTIGRID METHODS FOR THE PURE TRACTION PROBLEM OF LINEAR ELASTICITY: FOSLS FORMULATION

  • Lee, Chang-Ock
    • 대한수학회논문집
    • /
    • 제12권3호
    • /
    • pp.813-827
    • /
    • 1997
  • Multigrid methods for two first-order system least squares (FOSLS) using bilinear finite elements are developed for the pure traction problem of planar linear elasticity. They are two-stage algorithms that first solve for the gradients of displacement, then for the displacement itself. In this paper, concentration is given on solving for the gradients of displacement only. Numerical results show that the convergences are uniform even as the material becomes nearly incompressible. Computations for convergence rates are included.

  • PDF

Improvement of Power Quality in DC Traction Systems Using Statcom

  • Hosseini, Seyed Hossein;Sarhangzadeh, Mitra;Ajami, Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.164-168
    • /
    • 2005
  • In this paper a statcom is developed to improve the power quality in a dc traction system. The proposed statcom can be used as both inverter and active filter. As an active filter, it can compensate harmonic distortion and reactive power and as an inverter, it can recycle regenerative energy caused by decelerating trains. The simulation results are carried out by using PSCAD/EMTDC software.

  • PDF

타이어 로울러 개발을 위한 유압 시스템 설계 및 차량 동역학적 모델링에 관한 연구 (Research on Hydraulic System Design and Vehicle Dynamic Modeling for the Development of Tire Roller)

  • 김상겸;김준호;이운성;김정하
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.201-211
    • /
    • 2002
  • In this research, we are trying to research about hydraulic system design and vehicle dynamic modeling far the development of the tire roller. The reason why we would like develop it is that tire roller is one of the most useful machine for the road construction site and application other construction equipments. Here, we conceptualize the new hydraulic system and derive the equations of motion fur dynamic analysis and also investigate system modeling by using a DAQ board. We design the hydraulic circuit of steering and traction mechanism system. This design can be used to create virtual prototypes of construction equipment. So, we studied tire roller to integrate development technology. In system analysis, we formulate hydraulic traction system model and hydraulic steering system model. Also, we integrate DAQ system to acquire experimental results in real tire roller equipment.

직류전동차 탑재용 피뢰기의 최적선정에 관한 연구 (A Study on the Optimal Selection of Lightning Arresters for DC Electric Traction Vehicles)

  • 길경석;류길수;송재용;김일권;박대원;한문섭
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.112-116
    • /
    • 2007
  • In this paper, we proposed a selection and application recommendations of ZnO arresters for DC electric traction vehicles. To decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_r$), and the Nominal Discharge Current(In), we measured and analyzed system voltages and surge currents flowing the arrester installed on a DC electric traction vehicle under running state. System voltages measured up to 1,800 V in 1,500 V-system, and surge currents were recorded up to 3 times per a running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and a standard EN50163, we could proposed $U_C$, $U_r$, and In available for the 1,500 VDC electric traction vehicles.

Prospects for the use of Multiphase Inverter-fed Asynchronous Drives in the Field of Traction Systems of Railway Vehicles

  • Brazhnikov, Andrey V.;Belozerov, Ilya R.
    • International Journal of Railway
    • /
    • 제5권1호
    • /
    • pp.38-47
    • /
    • 2012
  • At present among the most important problems in the field of traction systems of railway vehicles are the following: 1) the minimization of the mass-and-overall dimensions of the drive systems; 2) the increase of the drive systems reliability and obtaining their higher fault-tolerance abilities; 3) the minimization of the motion speed pulsations and its oscillations, etc. The results of the researches received by the authors of this paper show that the use of the multiphase (i.e. having the number of phases more than four) inverter-fed induction motors in these traction systems is the most effective way of solving the above mentioned problems. In this case the motion speed oscillations can be decreased only by the increase of the drive phase number without any change in the inverter control algorithm. In addition, the application of some non-traditional control methods in the multiphase asynchronous traction drive system of a railway vehicle allows to decrease the mass-and-overall dimensions of the system and to improve its reliability and some other technical-and economic characteristics.

DC전철구간의 에너지회생장치 개발 방향 (Direction for Development of Energy Regeneration Device for DC Electric Railway System)

  • 김용기;배창한;한문섭;양영철;장수진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가 (An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System)

  • 정호성;김주욱;신승권;김형철;안태풍;윤준석
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.