• Title/Summary/Keyword: Trace Monitoring

Search Result 203, Processing Time 0.042 seconds

Multivariate CUSUM control charts for monitoring the covariance matrix

  • Choi, Hwa Young;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.2
    • /
    • pp.539-548
    • /
    • 2016
  • This paper is a study on the multivariate CUSUM control charts using three different control statistics for monitoring covariance matrix. We get control limits and ARLs of the proposed multivariate CUSUM control charts using three different control statistics by using computer simulations. The performances of these proposed multivariate CUSUM control charts have been investigated by comparing ARLs. The purpose of control charts is to detect assignable causes of variation so that these causes can be found and eliminated from process, variability will be reduced and the process will be improved. We show that the charts based on three different control statistics are very effective in detecting shifts, especially shifts in covariances when the variables are highly correlated. When variables are highly correlated, our overall recommendation is to use the multivariate CUSUM control charts using trace for detecting changes in covariance matrix.

Line of Sight Vector Estimation using UWB for Augmented Reality Based Indoor Location Monitoring System

  • Chun, Sebum;Seo, Jae-Hee;Lee, Sangwoo;Heo, Moon-Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.3
    • /
    • pp.145-156
    • /
    • 2016
  • A variety of methods for indoor positioning systems have been underway to ensure the safety of emergency rescuers who are working in dangerous situations such as fire fighters. However, since most systems display locations of rescue workers in two-dimension (2D)-based maps, it is difficult for a commander located in the outside to recognize locations of rescuers inside the building intuitively. An augmented reality (AR)-based indoor positioning monitoring system can display locations of rescuer inside the building that can be seen by commanders to help intuitive recognition of positioning. To monitor AR-based indoor positioning, it is necessary to have an estimation technique of line of sight vector of observers. In the present study, an estimation technique of a line of sight vector using ultra-wide band tranceiver installed inside the indoor to trace locations is presented.

INFORMATION SYSTEM ON INTEGRATED RADIATION SAFETY (ISIRS) AND ORPHAN SOURCES CONTROL IN KOREA

  • Lee, Dewhey
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.255-263
    • /
    • 2001
  • An Orphan Sources Control program controlled by a web based information system in Korea has been developed to satisfy the national demand on a total management of and integrated radiation safety. There are, currently, three approaches going on to control and manage the orphan sources in Korea. First, Korean regulatory authority has been conducting scrutinizing investigation on and thoroughly monitoring the possession of unlicensed radioactive sources from the late 1990s. Second, the regulatory authority will fully operate an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the mid 2001. Finally, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect the scrap metals when they attempt to reutilize metals to prevent from being contaminated by uncontrolled sources through the scrap monitoring systems.

  • PDF

Smart Toothbrush System Development Using Auto Tooth brushing Position Detection (자동 위치 검출을 이용한 지능형 칫솔 시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Kim, Dong-Jun;Yun, Tae-Ho;Yang, Heui-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1908-1909
    • /
    • 2007
  • The design of an intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing is described. Inappropriate Toothbrushing styles, even in adults, sometimes cause dental problems, cavities, gingivitis, etc. This smart system provides user to monitor his or her brushing pattern using accelerometer and magnetic sensors for evaluation of toothbrushing style. Directional information of toothbrush with respect to earth's magnetic field and activity data were measured by a miniaturized low-power micro- controller, MSP430 and transmitted to personal computer by 2.4GHz radio transmitter, nRF2401. A personal computer provides an on-line display of activity and orientation measurements during toothbrushing. The signal trace is then analyzed to extract clinically relevant measurement. This preliminary study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style.

  • PDF

Spatial and Temporal Changes in Sediments of Major Tidal Flats in the Western and Southern Korean Coasts: Grain Size, Organic Matter, Trace Metals (한반도 서·남해 주요 갯벌 퇴적물의 시·공간적 변화: 입도, 유기물, 중금속)

  • KIM, EUNYOUNG;RYU, SANG-OK;CHOI, DAE-UP;LEE, JAE-HWAN;OH, HA-NEUL;OH, SUN-KWAN;KHO, BYUNG-SEOL;KIM, YOUNG NAM;YEO, JEONG WON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2019
  • As a part of the national marine ecosystem monitoring program, the temporal and spatial variation of sedimentary environment and pollution of organic matters and trace metals from four major tidal flats, i.e., Ganghwa Is., Garolim bay, Jeung Is., Suncheon bay, was investigated for 3 yerars from 2015 to 2017. The mean grain size of the sediment was $5.0-5.3{\varnothing}$ at Ganghwa Is, $4.5-4.8{\varnothing}$ at Garolim bay, $6.1-6.5{\varnothing}$ at Jeung Is, and $8.6-8.7{\varnothing}$ at Suncheon bay. The mean grain size (Mz) tended to decrease from the north (Ganghwa Is.) to the south (Suncheon bay). The ignition loss (IL) was 15.5% in Suncheon bay in 2015, which was relatively high compared to other sites, but gradually decreased over time from 8.3% in 2016 to 7.0% in 2017. In Jeung Is. and Suncheon bay, the concentration of Zn and As exceeded the threshold effect level (TEL) at some stations, but the range of trace metals in the other sites was below the level. In Jeung Is., the Mz and concentration of trace metals except Hg was positively correlated (r= 0.40-0.88, P<0.05). On the other hand, Mz was negatively correlated with trace metals (P<0.05) in Suncheon bay. The geoaccumulation index ($I_{geo}$) to evaluate contamination status of sediments for trace metal was less than 1(not contaminated) for Cu, Zn, Pb, Cd and Hg, and 2-3 (moderately to strongly polluted) for As at several stations in Suncheon bay and Jeung Is.

Preparation of Simultaneous Analysis Method of PAHs (Polycyclic Aromatic Hydrocarbons) and Monitoring PAHs in Groundwater (지하수 중 다환방향족탄화수소류(PAHs, Polycyclic Aromatic Hydrocarbons)의 동시분석법 마련 및 수질실태조사)

  • Kim, Deok Hyun;Park, Sunhwa;Yoon, Jong Hyun;Choi, Hyojung;Kim, Moonsu;Jeong, Do Hwan;Kim, Young;Kim, Hyun-Koo
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.4
    • /
    • pp.67-76
    • /
    • 2020
  • Polycyclic aromatic hydrocarbons (PAHs) are organic compounds that tend to persist in environmental media for a long period of time. This work presents a 2-year monitoring study of occurrence of three PAHs (benzo(a)pyrene, naphthalene, and fluoranthene) in groundwater. The groundwater samples were collected from 106 sites of nation's groundwater quality monitoring network and analyzed by simultaneous analysis method to quantify the concentrations of the PAHs. Benzo(a)pyrene was not detected in all samples. Naphthalene and fluoranthene concentrations ranged from not detected to 12.8 ng/L and not detected to 10.5 ng/L with their detection frequency being 57.8 and 4.2%, respectively. The concentrations of PAHs in ground- and drinking waters are not currently regulated in Korea, but the concentration levels of naphthalene and fluoranthene found in this work were lower than the regulatory limits of other countries (naphthalene 0.001~0.07 mg/L, fluoranthene 0.001~1.4 mg/L). The monitoring result of this study revealed that PAHs exist as trace amounts in domestic groundwater, however continuos monitoring is necessary to protect groundwater from PAHs contamination with growing industrialization and urbanization.

DNA-functionalized single-walled carbon nanotube-based sensor array for gas monitoring

  • Zhang, Wenjun;Liu, Yu;Wang, Ming. L
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.73-95
    • /
    • 2013
  • Nine deoxyribonucleic acid (DNA) sequences were used to functionalize single-walled carbon nanotube (SWNT) sensors to detect the trace amount of methanol, acetone, and HCl in vapor. DNA 24 Ma (24 randomly arranged nitrogenous bases with one amine at each end of it) decorated SWNT sensor and DNA 24 A (only adenine (A) base with a length of 24) decorated SWNT sensor have demonstrated the largest sensing responses towards acetone and HCl, respectively. On the other hand, for the DNA GT decorated SWNT sensors with different sequence lengths, the optimum DNA sequence length for acetone and HCl sensing is 32 and 8, separately. The detection of methanol, acetone, and HCl have identified that DNA functionalized SWNT sensors exhibit great selectivity, sensitivity, and repeatability with an accuracy of more than 90%. Further, a sensor array composed of SWNT functionalized with various DNA sequences was utilized to identify acetone and HCl through pattern recognition. The sensor array is a combination of four different DNA functionalized SWNT sensors and two bare SWNT sensors (work as reference). This wireless sensing system has enabled real-time gas monitoring and air quality assurance for safety and security.

On-Line Monitoring of Low Biochemical Oxygen Demand Through Continuous Operation of a Mediator-Less Microbial Fuel Cell

  • MOON, HYUN-SOO;CHANG, IN-SEO;JANG, JAE-KYUNG;KIM, KYUNG-SHIK;LEE, JI-YOUNG;LOVITT, ROBERT W.;KIM, BYUNG-HONG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.192-196
    • /
    • 2005
  • Abstract Oligotrophic microbial fuel cells (MFCs) were tested for the continuous monitoring of low biochemical oxygen demand (BOD) by using artificial wastewater, containing glucose and glutamate, as check solution. Ten times diluted trace mineral solution was used to minimize the background current level, which is generated from the oxidation of nitrilotriacetate used as a chelating agent. The feeding rate of 0.53 ml/min could increase the sensitivity from 0.16 to 0.43 ${\mu}$A/(mg BOD/l) at 0.15 ml/min. The dynamic linear range of the calibration curve was between 2.0 and 10.0 mg BOD/l, and the response time to the change of 2 mg BOD/l was about 60 min. The current signal from an oligotroph-type MFCs increased with the increase in salts concentration, and the salt effect could be eliminated by 50 mM phosphate buffer.

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

An Exception Monitoring System for Developing Reliable Java Programs (신뢰성 높은 JaVa 프로그램 개발을 위한 예외 모니터링 시스템)

  • Oh Heejung;Chang Byeong-Mo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.471-476
    • /
    • 2005
  • Exception mechanism in Java allows programmers to define, throw and catch exceptional conditions. It is important for the development of reliable programs to make sure that exceptions are handled appropriately at run-time. In this paper, we develop an exception monitoring system, which can help programmers trace and handle exceptions effectively. Using this system, programmers can examine exception handling process in detail by tracing only interesting exceptions, and can handle exceptions more effectively. To reduce performance overhead, we design the system based on code instrumentation. Moreover, we show the effectiveness of the system by experiments on benchmark programs.