• Title/Summary/Keyword: Toxic gas

Search Result 496, Processing Time 0.032 seconds

A Study on the Stable Operation of High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 안정적 운영에 관한 연구)

  • Cho, Haejin;Na, Chanwook;Ko, Sungho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2017
  • Sodium hypochlorite, used as water disinfectant, is generated by electrolysis of salt. Compared to chlorine gas disinfection, it is free from high-pressure gas regulation and does not generate toxic gas, so it is increasingly used as a safe disinfectant. Despite these advantages, the concentration of sodium hypochlorite decreases with temperature during long-term storage, and the amount of chlorate increases when a large amount is added, it has mainly been applied to small-scale waterworks. To solve this problem, high sodium hypochlorite generation was developed. In this study, the changes of concentration and chlorate of sodium hypochlorite with time has been studied. As a result of the test, it was found that the usable period of sodium hypochlorite produced at a certain temperature or less was increased from 1.5 days to 13 days. Overall, sodium hypochlorite can be applied even in large-scale waterworks, which makes operation more stable and also reduces the disinfection byproducts, thus it contributed greatly to securing water quality.

Development of Tank Lorry Monitoring System for Safety Using Intelligent Computing Device (지능형 단말기를 사용한 탱크로리 운행 안전 모니터링 시스템 개발)

  • Lee, Choon-Young;Bae, Ki-Man;Park, Geun-Young;Lee, Dong-Jin;Lim, Jeong-Sik;Lee, Sang-Ryong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.42-47
    • /
    • 2008
  • It is important for national safety that tank lorry or bulk lorry which is carrying toxic gas or explosive materials should be monitored during the maneuvering from starting point to destination as well as vehicle or tank status. Therefore, we propose a safety monitoring system for tank lorry to check driving condition and the vehicle status. We studied the integration of central control system with in-vehicle computer system connected with various sensors for monitoring through a communication network.

  • PDF

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

The Enhancement of Selectivity in Thick Film SnO2 Gas Sensors by Additives and Pattern Recognition (첨가제 및 패턴인식에 의한 후막 SnO2 가스센서의 선택성 향상)

  • 정해원;김종명;박희숙;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1073-1077
    • /
    • 2003
  • The Sn $O_2$-based gas sensors can detect inflammable and toxic gases of low concentration by the modulation of surface resistance, but they lack in selectivity on the whole. To give selectivity to the Sn $O_2$-based gas sensors, studies on the sensing mechanism, selective gas sensing materials and signal processing techniques are demanded. Ethanol (C$_2$ $H_{5}$OH) and acetonitrile ($CH_3$CN) were confirmed to undergo catalytic oxidation on Sn $O_2$ by gas chromatography. PdCl$_2$-doped Sn $O_2$ showed excellent sensitivity to ethanol and acetonitrile, while La$_2$ $O_3$-doped Sn $O_2$ showed excellent sensitivity to ethanol, but poor sensitivity to acetonitrile. Using these two sensors and pattern recognition, the selectivity to acetonitrile is greatly enhanced. The minimum detection level of acetonitrile was 15 ppm in air and 20 to 100 ppm when exposed to interfering gases together with acetonitrile.

Development and validation of a portable gas chromatograph method for quantitative determination of oxygen and toxic gas impurities in medical oxygen using planar microchromatographic columns and detectors

  • Ekaterina V. Galeeva;Roman R. Galeev;Prachi Sharma;Alexander l. Khokhlov;Dmitry V. Somov;Dmitry A. Semanov;Ilshat R. Aryslanov;Natalia А. Lezhnina;Vladimir Platonov;Nishant Tripathi
    • Analytical Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.261-270
    • /
    • 2024
  • This study examines portable Gas Chromatography (GC) for the quantitative analysis of oxygen and impurities, focusing on the development and validation of a method to determine oxygen, carbon monoxide, carbon dioxide, methane, and nitrogen in medical compressed oxygen gas. The goal is to ensure the quality of medicalgrade oxygen. The method's validation assessed its metrological characteristics, demonstrating specificity through clear chromatographic separation of the target gases and the absence of these peaks in the carrier gas chromatogram. It exhibited linearity within the designated concentration ranges, while precision met permissible standards, with the relative standard deviation for intermediate precision being less than 4% for carbon monoxide (0.00025 - 0.00099 %), less than 3 % for methane (0.0005 - 0.00246%) and carbon dioxide (0.0050 - 0.0150 %), less than 2% for nitrogen (0.1 - 0.7 %), and less than 0.01% for oxygen (99.27 - 99.98%). Overall, the validation results confirm the suitability of this analytical method for the quantitative determination of the aforementioned gases in medical compressed oxygen using portable GC with microchromatographic columns and detectors.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.

A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method (가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구)

  • Shim, Ji-Hun;Lee, Jae-Geol;Han, Kyoung-Ho;Kim, Ju-Wan;Song, Seok-Hun;Jo, Hyung-Won;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.519-524
    • /
    • 2022
  • Domestic building finishing materials are being evaluated according to KS F 2271 standards according to the notification of the Ministry of Land, Infrastructure and Transport, and this test is evaluated using laboratory animals. In this study, experiments were conducted on highly combustible organic insulation materials such as EPS, urethane, and phenolic foam. The purpose of this study was to analyze the cause of the behavioral suspension of the experimental mice by measuring the average behavioral suspension time of the mice caused by the harmful gas generated when these three types of insulation materials were burned. FTIR analysis and smoke density experiment were performed as a cause analysis method for the behavioral suspension of mice, and the experimental results were analyzed by dividing the causes of behavioral suspension into suffocation by particulate matter and toxic inhalation by gaseous substances. As a result of the test, urethane was evaluated as the most harmful insulation material, and as a result of FTIR analysis and smoke density test as a cause analysis for the gas toxicity test results, it is judged that the behavioral stop of the rats by suffocation is higher than the effect of toxic inhalation. This study is a basic study on the cause analysis of harmful gases, and it will be necessary to prepare the toxicity basis and analyze various materials and gases.

A Toxicity of Interior Upholstery in Apartment Housing (아파트 마감재의 연기 유독성)

  • Ham, Sang-Keun;Kim, Hong;Han, Sang-Bum;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.36-43
    • /
    • 2001
  • Several types of widely used interior upholsteries including wallpaper, veneer board and floor cover, were selected to be evaluated by using the method of NES 713 text. Test results indicates that a fire with retardant wallpaper release a large amount of toxic gases when constantly exposed to a fire source. When evaluated in terms of the masses of released gases, the release of Carbon monoxide appears the highest in case of wallpaper fire, while the ratio of CO/Mass loss appears the highest in case of floor cover fire. Therefore, it can be concluded that, a large amount of toxic gas will release from a floor cover fire with even a small quantity of fuel.

  • PDF

Adsorption of ammonia using mesoporous alumina prepared by a templating method

  • Yeom, Changjoo;Kim, Younghun
    • Environmental Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • Ammonia, $NH_3$, is a key chemical widely used in chemical industries and a toxic pollutant that impacts human health. Thus, there is a need for the development of effective adsorbents with high uptake capacities to adsorb $NH_3$. An adsorbent with a high surface area and a small pore size is generally preferred in order to have a high capacity for the removal of $NH_3$. The use inorganic nanoporous materials as gas adsorbents has increased substantially and emerged as an alternative to zeolite and activated carbon. Herein, mesoporous alumina (MA) was prepared and used as an $NH_3$ adsorbent. MA showed good pore properties such as a uniform pore size and interlinked pore system, when compared to commercial adsorbents (activated carbon, zeolite, and silica powder). MA has free hydroxyl groups, serving as useful adsorption sites for $NH_3$. In an adsorption isotherm test, MA exhibited 4.7-6.5 times higher uptake capacities for $NH_3$ than commercial adsorbents. Although the larger surface areas of adsorbents are important features of ideal adsorbents, a regular and interlinked adsorbent pore system was found to be a more crucial factor to adsorb $NH_3$.

Production of T-2 Toxin and Its Metabolites by Fusarium sporotrichioides Isolates from the Corn Producing Area in Korea (우리나라 옥수수산지에서 분리한 Fusarium sporotrichioides 균주들에 의한 T-2 독소 및 관련 대사물의 생성)

  • Lee, Yin-Won;Kim, Kook-Hyung;Chung, Hoo-Sup
    • The Korean Journal of Mycology
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 1990
  • Four isolates of Fusarium sporotrichioides obtained from the corn producing area were tested for their toxicities by feeding the crude cultures to rats. Three out of four isolates were highly toxic and killed all rats within 3-4 days after feeding. The chemical analyses of toxic cultures by thin layer chromatography and gas chromatography-mass spectrometry revealed that two isolates from Jeongsun district produced T-2 toxin and its related trichothecenes. This is the first report that F. sporotrichioides isolates produce T-2 toxin in Korea.

  • PDF