• Title/Summary/Keyword: Toxic gas

Search Result 495, Processing Time 0.032 seconds

Establishment of Korea Gas Safety Standards for Hydrogen Appliance Inspection in Accordance with Hydrogen Law (수소법에 따른 수소용품 검사시행에 대비한 기술기준 제정)

  • Jung, Jae-Hwan;Kim, Wan-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.80-84
    • /
    • 2021
  • As the Hydrogen law was enacted, 4 types of hydrogen appliances were designated as inspection products. The types of hydrogen appliances are water electrolysis equipment, hydrogen extraction equipment, stationary fuel cells, and mobile fuel cells. The establishment fo safety standards for hydrogen appliance inspection defines risk factors for each hydrogen appliance and stipulates safety standards to prevent risk factors. The main safety standards for each hydrogen appliance are hydrogen quality and safety control for water electrolysis, toxic substances emission prevention and carbon monoxide emission prevention for hydrogen extraction facilities, vibration safety for mobile fuel cells.

A System on Air Dispersion System for Toxic Gas on Energy Plant Environment (에너지 플랜트 환경에서 독성가스를 위한 대기확산 시스템에 관한 연구)

  • Oh, Jeong-Seok;Sohn, Choong-Yeon;Sung, Jong-Gyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.1074-1077
    • /
    • 2011
  • 국내외 대규모 산업시설은 유해물질과 직 간접적으로 밀접하게 관련되어 유해물질 누출사고는 막대한 물적, 인적 피해를 발생시키며 누출물질, 저장시설, 대기 상태에 따라 유해물질 확산 속도 및 범위가 다르기 때문에 이를 예측하는 대기확산 시스템이 필요하다. 또한 기존의 대기확산 시스템은 산업시설 구조물 설계 단계에서 안전성을 확인하는 시뮬레이션용으로 사용되었기 때문에 누출사고 발생 시 즉각적인 처리와 대응이 어려우며 전문적 지식수준의 사용자 입력을 요구한다. 본 논문은 에너지 플랜트 환경의 특수성과 효율성을 고려하여 운영 중인 시설에 적용 가능한 대기확산 시스템 연구를 목적으로 한다. 이를 위하여 신속하고 효율적인 대기확산 모델을 선정 정의하고 융통성 있는 대기확산 시스템의 구성요소를 컴포넌트화하여 구현하였으며 사고 발생 시 빠르게 피해범위를 예측할 수 있는 실시간 대기확산 시스템 설계 방안을 제시하였다.

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Application of Membranes for Biological Waste Gas Treatment Processes (생물학적 폐가스 처리공정 내 멤브레인 활용)

  • Lee, Sang-hun
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.327-332
    • /
    • 2021
  • The use of membranes for MBRWG (Membrane Bioreactor for Waste Gas) treatment can provide highly selective separation of a waste gas stream followed by effective biological removal. MBRWG have several potential advantages, among which the most distinctive one is separation of gas and liquid phases at each side of membrane potentially allowing the optimal biomass control toward effective biodegradation of target gases as well as biofilm activation. This advantage becomes especially favorable for removal of hydrophobic toxic gases, such as xylene, by MBRWG systems, because the mass transfer, the toxicity, and thereby the biodegradation of hydrophobic gas treatment requires sensitive handling of liquid stream and water control near biofilm. Among various membranes for MBRWG treatment, PDMS-hollow fiber membranes provide the high gas mass transfer. Despite lower specific surface areas, capillary type membranes are also applied current MBRWG studies. In addition to the main application of membranes as biofilm supporter in MBRWG systems, there can be another application of membranes in a posterior process for removal of residual gases or dusts emitted from conventional biological waste gas treatment processes.

A Study on the Safety Distance of Benzene and Acrylonitrile Releases in Sccordance with Dike and Hole Size (벤젠 및 아크릴로나이트릴 누출시 방류벽 유무 및 누출공에 따른 피해 영향범위 산정에 관한 연구)

  • Kawg, Youngmin;Oak, Jaemin;Yoon, Sukyoung;Jung, Seungho
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • As the industries become more developed, the amounts of hazardous materials have been increased. Because of that, the possibility of accidents in plants is expected to increase. Especially, the dispersions of toxic materials cause serious effect to human life and environment, So it is very important to confirm safety distance of discharge accident. For this paper, we proposed new algorithms for toxic liquid, such as benzene and acrylonitrile. and using this argorithm, we are going to predict safety distance. The scenario of accidental release was assumed to be the release of entire quantity in 10 minutes is defined as worst-case scenario and Instantaneous release. Also the release from a partial rupture of line is used as an alternative case scenarios as NICS(National Institute of Chemical Safety) guidelines. Using ALOHA program and the algorithm for liquid toxic materials and suggested the graph, as well as correlated equations which can utilize emergency responders.

An Implementation of an Integrated Degasing System for Aluminum Molten Metal in Continuous Casting (알루미늄 연속주조 용탕의 탈 가스 일체화 장치 개발)

  • Lee, Yong-Joong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • There are some methods that have been used to manage a degasing process in recent years, such as an injection method that uses aluminum molten metal powder and chemicals supplier and input method that supplies argon and nitrogen, or chlorine gas by using a gas blow-tube. However, these methods show some problems, and it shows that it is a difficult process to handle, pollution due to producing a lot of toxic gases like chlorine and fluoride gas, irregular effects, and lowering work efficiency due to the excessive processing time. The problems that are the most fatal are the producing a lot of sludge due to the reaction of aluminum molten metal with chemicals, loss of metals, and decreasing the life of refractory materials. In order to solve these problems, this paper develops a technology that is related to aluminum continuous casting molten metal and monolithic degasing apparatus. A degasing apparatus developed in this study improved the existing methods and prevented environmental pollution with smokeless, odorless, and harmlessness by using a new method that applies argon and nitrogen gas in which the methods used in the West and Japan are eliminated. The method developed in this study decreases the molten metal processing and settling time compared to the existing methods and improves the workers' health, safety, and environment because there is no pollution in processes.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

The Electron Temperature and Density Properties of Mixed Gases in ICP Lighting System : (Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe 및 Ne:Ar 혼합가스의 전자온도 및 전자밀도 특성)

  • Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee;Choi, Gi-Seung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.156-160
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem and root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixed gas lamp improve firing voltage of Xe gas lamp. Purpose of this study is to understand ideal mixing-ratio of Ne:Xe and Ne:Ar gas by electron temperature and electron density for mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by single-Langmuir probe. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

Characteristics of the Ceramic Filter with the Control of Particle Size and Graphite Additive for the Hazardous Particle and Gas Removal (입도와 흑연 첨가제에 따른 유해 입자 및 가스 동시제거용 세라믹필터 특성평가)

  • Cho, Eul-Hun;Lee, Kun-Jae
    • Journal of Powder Materials
    • /
    • v.21 no.6
    • /
    • pp.454-459
    • /
    • 2014
  • In this study, the porous ceramic filter was developed to be able to remove both dust and hazardous gas contained in fuel gas at high temperature. The porous ceramic filters were fabricated and used as a catalyst support. And the effects have been investigated such as the mean particle size, organic content and addition of foaming agent on the porosity, compressive strength and pressure drop of ceramic filters. With the increase of mean powder size and the organic content for the cordierite filter, the porosity was increased, but the compressive strength and pressure drop were decreased. From the results of the research, the optimum condition for the fabrication of ceramic filters could be acquired and they had the porosity of 58%, the compressive strength of 13.4 MPa and the pressure drop of 250 Pa. It was expected that this ceramic filter was able to be applied to the glass melting furnace, combustor, and dust/toxic gas removal filter.

Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor (중공사막 접촉기를 이용한 암모니아 물질전달 모델링)

  • Oh, Dae-Yang;Jeong, Joo-Young;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.