• Title/Summary/Keyword: Total residual chlorine

Search Result 41, Processing Time 0.023 seconds

Study on Distribution of Microbes in Waterscape Facilities in Gyeonggi-do (경기도내 물놀이형 수경시설 중 미생물 분포 조사 연구)

  • Jeong, Ah-Yong;Park, Myoung-Ki;Kim, Yun-Sung;Lee, Chang-Hee;Lee, Jung-Hee;Lee, Hye-Yeoun;Kim, Young-Suk
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.710-718
    • /
    • 2020
  • Objectives: We analyzed water in waterscape facilities to investigate contamination levels of water-borne pathogens and four test items (pH, turbidity, residual chlorine, and Escherichia coli) at facilities including play fountains, splash parks, and artificial streams from June to October in Suwon City and in the whole of Gyeonggi-do. Methods: A total of 62 waterscape facility samples were collected from 36 sites and tested for pathogenic Escherichia coli and water-borne viruses that cause hand-foot-and-mouth disease, eye disease, and acute enteritis. Results: None of the water-borne pathogens were detected in waterscape facility samples collected from across Gyeonggi-do that were for pre-inspection for facility management. However, the results of samples from Suwon collected in hot weather and during the school vacation period showed five total inconsistencies in turbidity (four cases) and Escherichia coli (one case). Three out of the four inconsistent samples in turbidity were from the same facility which operated a sand filtration system due to its locational factors close to mountains. Conclusion: We suggest that the waterscape facilities in Gyeonggi-do are managed properly in the respect of microbial contamination and water quality.

Harmful Chemicals Migrating from Plastic Hoses Using Household into Tap Water (가정용 고무호스에서의 유해화학물질 용출)

  • Bae, Seok-Mun;Son, Hee-Jong;Jeong, Hyun-Chul;Choi, Jin-Taek;Bin, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.900-904
    • /
    • 2010
  • Polyvinyl chloride (PVC) hoses, polyethylene hose and silicone hose for tap water were tested with respect to migration of phenolic compounds to water. The highest concentrations (0.36~1.97 mg/L) of total phenolic compounds were observed in the test water from PVC hoses. Increasing residual Cl concentration from 0 to 0.5 mg/L or increasing water temperature from 4 to $25^{\circ}C$ increased 3~3.2 times and 100~104 times for migrated total phenolic compounds concentrations, in respectively. A major migrating phenolic compounds from PVC hoses were bisphenol-a (BPA) and it was observed that the concentration of migrating phenolic compounds in the order: DEHP > 2-chlorophenol > 2,4,6-trichlorophenol > 2,4-dichlorophenol from PVC hoses.

Analysis of Microbial Contamination in Poultry Slaughtering Operations for the Application of HACCP (HACCP 적용을 위한 도계처리 공정내 미생물 오염의 분석)

  • 홍종해;권혁무;고주언
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • The application of HACCP system, which was adopted by Codex Alimentarius Committee for the safe meat and poultry production, is one of the urgent task for competing in the world trade markets. But there have been no useful analytical studies to identify the causes of contamination in the poultry meat processing plants in Korea. This study was conducted to investigate the potential hazards during the operations by the microbiological examination for the poultry meat processing plant (20,000 birds capacity a day) located in Kangwon province. In spite of air contamination of work places, it may not directly affect the surface contamination of poultry meats. But the risk of Campylobacter jejuni/coli contamination was high. The number of total count was decreased about ten times, but remarkable changes of microbial contamination could not be recognized in each procedure during the operations. The washing water was already contaminated as much as $10^{3-6}CFU/ml$ in SPC before the operations. It means that to keep water tanks hygienic is a primary step to prevent the occurrences of microbial contamination. The overflow and recirculation of water in scalding, washing, and chilling was aslo an important factor for a hygienic control. Based on this study, the followings could be regarded as an important factors for hygenic control in the poultry slaughtering plants on a small scale. The temperature of water used for scalding should be constantly maintained on a required temperature, and the overflow rate of 1~1.5 liter per bird. The carcass surface and the body cavity should be washed thoroughly and the cross-contamination due to facilities, workers, and tools should be prevented. The chilling water sholud be maintained under 5$\circ$C of temperature with ice and overflow, and residual chlorine level of 50 ppm.

  • PDF

Cleaning and Storage Effect of Electrolyzed Water Manufactured by Various Electrolytic Diaphragm (격막 방식에 따라 제조한 전해수의 세척 및 보관 효과)

  • 김명호;정진웅;조영제
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.160-169
    • /
    • 2004
  • This study was carried out to investigate the efficacy of electrolyzed water manufactured with or without diaphragm on sterilization and preservation of cut-celery and shelled raw oyster. In cut-celery, total viable cell count and coliform group in the treatment of electrolyzed water were decreased to about 1/200∼1/1,000 level and about 1/100 level comparing non-treated ones. But moisture content, pH, hardness, vitamin C and residual chlorine content were showed a little difference among treatments up to 10 days at 10$^{\circ}C$. L and a color values were gradually increased in all treatments, and color differences($\Delta$E) were remarkable between treatment and untreatment sample. In overall acceptability, cut-celery treated with electrolyzed water showed somewhat higher score than that of other ones treated with tap water and 100 ppm NaClO solution until 5 days of storage. After 48 hours of storage, it was showed that VBN, total viable cell count and coliform count of shelled raw oyster treated with electrolyzed alkali water produced by non-diaphragm system are lower by about 3 mg%, 1∼2 log cycle and 2 log cycle respectively than that of ones treated with sea water. Total viable cell count of shelled raw oyster just after treatment was lower by about 1 log cycle than that of ones treated with sea water, and any significant increment was not found after 24∼48 hours of storage.

Isolation and Managemental Method of Fungi Genera in Raw Water (수계에 존재하는 곰팡이속 분리동정 및 관리방안 조사)

  • Park, Hong-Gi;Jung, Eun-Young;Cha, Dong-Jin;Jung, Jong-Moon;Choi, Jin-Tack
    • Journal of Life Science
    • /
    • v.20 no.7
    • /
    • pp.1073-1077
    • /
    • 2010
  • Fungi, including allergenic, pathogenic or toxigenic species, may have direct effects on human health, interfere with the disinfection process and maintenance of chlorine residual, and add to taste and odor problems. We surveyed distribution of waterborne fungi from raw water in Busan metropolitan city using the EPA standard method. According to the survey, conducted from March 2008 to October 2008, the number of fungi in raw water was high in September and low in April. Quantitative enumeration of fungi per 100 ml of raw water ranged from 5 to 64 CFU, and a higher number was detected in the Mulgum region compared to the Maeri region. Total fungi numbers highly correlated with pH, water temperature and total coliform in this area. Predominant fungi genera grown in medium were identified as Aspergillus, Penicillum, Histoplasma, Rhizopus, Trichophyton, Mucor and Sporthrix species. Aspergillus flavus and Penicillum notatum were particularly dominant in both areas. There were a total of 6 and 9 species detected in the Mulgum and Maeri regions respectively, and the number of species was more verified in the Maeri region than the Mulgum region.

Concentration distributions and formation characteristics of trihalomethanes in drinking water supplies to rural communities (농촌지역 마을상수 중 trihalomethanes의 농도 분포 및 생성 특성)

  • Kim, Hekap;Kim, Seyoung
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.58-64
    • /
    • 2015
  • This study aimed to investigate the concentration distributions and formation characteristics of trihalomethanes (THMs) in drinking water supplies to rural communities. Water samples were collected twice from 40 rural households located on the outskirts of Chuncheon city of Gangwon Province in the summers of 2010 and 2011, and urban drinking water samples were collected from 20 faucets during the same period in 2011 for comparison purpose. Water temperature, pH, and residual chlorine (total and free) concentrations were measured in the field, and samples were analyzed for dissolved organic carbon (DOC) and THM concentrations in the laboratory. The average DOC concentrations in rural water samples were not greatly different between groundwater (n = 20) and surface water (n = 20) which were used as sources for drinking water (1.81 vs. 1.91 mg/L). However, the average concentrations of total THMs (TTHMs) in groundwater ($9.77{\mu}g/L$) were much higher than those in surface water ($2.85{\mu}g/L$) and similar to those in urban drinking water samples ($10.8{\mu}g/L$). Unlike urban water supply, rural water (particularly groundwater) contained more brominated THM species such as dibromochloromethane (DBCM), suggesting its relatively high content of bromide ion (Br-). This study showed that rural water supplies have different THM formation characteristics from urban water supplies, probably due to their differences in source water quality properties.

Ship Sewage Treatment Using Fixed Media Method (고정식 메디아법을 이용한 선박의 오폐수 처리)

  • Han, Sang-Hwa;Lee, Dea-Ho;Nyung, Bu-Nyung;Bae, Sang-Bum;Yoon, Jong-Mun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The purpose of this study is to develop Sewage Treatment Plant that treat sewage which occurred in ship using fixed media method and to consider applicable to the Pilot Scale device of the STP regulations in MLTM(Ministry of Land, Transport and Maritime Affairs) and MEPC(Marine Environment Protection Committee). In test results, pH geometric mean was 7.68, $BOD_5$(Biochemical Oxygen Demand) geometric mean was 7.28 mg/l, $COD_{cr}$(Chemical Oxygen Demand) geometric mean was 48.39 mg/l, TSS(Total Suspended Solid) geometric mean was 18.00/l, Residual chlorine geometric mean was 0.19 mg/l, and E. coli geometric mean was 1CFU/100 ml. In addition, about 97.4% of $BOD_5$ was reduced, the $COD_{cr}$ reduction averaged 96.4%and the TSS reduction averaged 97.6%. STP have been determined by the MLTM and MEPC regulation of the marine pollution prevention equipment for performance testing product.

The Research Trend and Social Perceptions Related with the Tap Water in South Korea (수돗물 이용에 대한 국내 연구동향과 사회적 인식)

  • Kim, Ji Yoon;Do, Yuno;Joo, Gea-Jae;Kim, Eunhee;Park, Eun-Young;Lee, Sang-Hyup;Baek, Myeong Su
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.208-214
    • /
    • 2016
  • We analyzed research trend and public perception related with tap water to identify major factors affecting low consumption of tap water. 805 research articles were collected for text mining analysis and 1,000 on-line questionnaires were surveyed to find social variables influencing tap water intake. Based on the word network analysis, research topics were divided into 4 major categories, 1) drinking water quality, 2) water fluoridation, 3) residual chlorine, and 4) micro-organism management. Compared with these major research topics, scientific studies of drinking behavior, or social perception were rather limited. 22.4% of total respondents used tap water as drinking water source, and only 1% drank tap water without further treatments (i.e. boiling, filtering). Experience of quality control report (B=0.392, p=0.046) and level of policy trust (B=1.002, p<0.0001) were influential factors on tap water drinking behavior. Age (B=0.020, p=0.002) and gender (B= - 1.843, p<0.0001) also showed significant difference. To increase the frequency of drinking the tap water by social members, the more scientific information of tap water quality and the water policy management should be clearly shared with social members.

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF

Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes (상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구)

  • Seo, Jeewon;Lee, Gyusang;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.