• Title/Summary/Keyword: Total internal energy

Search Result 210, Processing Time 0.025 seconds

Turbine Design for Turbo-compound System to Recover Exhaust Gas Energy Using 1-D Mean Line Flow Model (1-D Mean Line Flow Model을 이용한 엔진 배기에너지 회수를 위한 터보컴파운드 시스템용 터빈 설계)

  • Jang, Jinyoung;Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.74-81
    • /
    • 2016
  • The aim of this study was to find the initial design value of turbine blade for electrical type turbocompound system generating 10 kW. Turbocompound is one of the waste heat recovery system applying to internal combustion engine to recover exhaust gas energy that was about 30 % of total input energy. To design the turbine blade, 1-D mean line flow model was used. Exhaust gas temperature, pressure, flow rate and turbine rotating speed was fixed as primary boundary conditions. The velocity triangles was defined and used to determine the rotor inlet radius and width, the rotor outlet radius at shroud and radius at hub, the rotor flow angles and the number of blades.

Aspects of Preliminary Probabilistic Safety Assessment for a Research Reactor in the Conceptual Design Phase (연구용원자로 기본설계에 대한 예비 확률론적 안전성 평가)

  • Lee, Yoon-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.102-110
    • /
    • 2019
  • This paper describes the work and results of the preliminary Probabilistic Safety Assessment (PSA) for a research reactor in the design phase. This preliminary PSA was undertaken to assess the level of safety for the design of a research reactor and to evaluate whether it is probabilistically safe to operate and reliable to use. The scope of the PSA described here is a Level 1 PSA which addresses the risks associated with core damage. After reviewing the documents and its conceptual design, eight typical initiating events are selected regarding internal events during the normal operation of the reactor. Simple fault tree models for the PSA are developed instead of the detailed model at this conceptual design stage. A total of 32 core damage accident sequences for an internal event analysis were identified and quantified using the AIMS-PSA. LOCA-I has a dominant contribution to the total CDF by a single initiating event. The CDF from the internal events of a research reactor is estimated to be 7.38E-07/year. The CDF for the representative initiating events is less than 1.0E-6/year even though conservative assumptions are used in reliability data. The conceptual design of the research reactor is designed to be sufficiently safe from the viewpoint of safety.

Comparing Solar Heat Shading Performances of Internal Blinds in the Summer (내측 블라인드의 하절기 일사열 차폐 성능 비교)

  • Park, Eun-Mi;Choi, Dong-Ho;Park, Min-Yong;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

Concentration of Polybrominated Diphenyl Ethers and Their Composition in Octopus minor Collected from Seosan Intertidal Zone (낙지(Octopus minor)에서의 브롬계화합물(Polybrominated diphenyl ethers, PBDEs)의 잔류농도와 조성특성)

  • Lee, Hyo-Jin;Kim, Gi-Beum;Stapleton, Heather
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.68-74
    • /
    • 2010
  • Octopus(Octopus minor), benthic cephalopod, were collected from intertidal zone in Seosan, Choongnam and analyzed for polybrominted diphenyl ethers(PBDEs). PBDEs concentrations ranged from 29 to 109 ng/g lipid wt(mean; 54 ng/g) in mantle and from 12 to 89 ng/g lipid wt(mean; 48 ng/g) in internal organ. PBDEs concentrations in octopus internal organ were lower about two times than that in common squid collected in Yellow Sea, indicating Seosan is relatively less contaminated with PBDEs. Major congener was BDE 206, occupying 72% and 49% of total PBDE concentration in mantle and in internal organ, respectively, which is very different from PBDE composition in common squid with major congeners of BDE 47 and 99. From PBDE composition, octopus seemed to concentrate higher brominated BDE rather than lower brominated BDE. This PBDE composition in octopus may be affected by sediment with extremely high contribution of deca-BDE to total PBDE concentration.

Characteristics of Vibration Response Imaging in Healthy Koreans

  • Choi, Kyu-Hee;Kim, Kwan-Il;Bang, Ji-Hyun;Kim, Jae-Hwan;Choi, Jun-Yong;Jung, Sung-Ki;Jung, Hee-Jae
    • The Journal of Korean Medicine
    • /
    • v.32 no.6
    • /
    • pp.10-17
    • /
    • 2011
  • Background: Vibration response imaging (VRI) is a new technology that records energy generated by airflow during the respiration cycle. Analysis of lung sound using VRI may overcome the limitations of auscultation. Objectives: To set a VRI standard for healthy Koreans, we conducted a clinical assessment to evaluate breath sound images and quantification in healthy subjects and compared the findings with reported breath sound characteristics. Methods: Recordings were performed using the VRIxp. Eighty subjects took a deep breath four times during a 12-second interval while sitting upright. The quantitative aspect was analyzed using the VRI quantitative lung data (QLD) for total left lung, total right lung and for six lung regions: left upper lung (LUL), left middle lung (LML), left lower lung (LLL), right upper lung (RUL), right middle lung (RML), right lower lung (RLL). The qualitative aspect was provided through image assessments by three reviewers. Results: In all regions the left lung had significantly higher QLD than the right lung (P<0.005, paired t-test). The inter-rater agreement was 0.78. 84% of the images were found normal by the final assessment. Among the 16% (n=13) of images with abnormal final assessment, the most common flawed features were dynamic image (77%, n=10) and maximum energy frame (MEF) shape (77%, n=10). No significant differences were found between males and females for QLD but there were significant differences in qualitative aspects including dynamic images, MEF shape, and missing LLL. Conclusion: The characteristics of healthy Koreans are similar to those of Western subjects reported previously. VRI is easy to use and objective, and so is helpful to diagnose patients with respiratory diseases and to monitor the progress of diseases after medical treatments.

Analysis of Elasto-Plastic Stress Waves by a Time-Discontinuous Variational Integrator of Hamiltonian (해밀토니안의 시간 불연속 변분적분기를 이용한 탄소성 응력파 해석)

  • Cho, S.S.;Huh, H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.231-234
    • /
    • 2008
  • This paper is concerned with the analysis of elasto-plastic stress waves by a time discontinuous variational integrator based on Hamiltonian in order to more accurate results in one dimensional dynamic problem. The proposed algorithm adopts both time-discontinuous variational integrator and space-continuous Hamiltonian so as to capture discontinuities of stress waves. This study enables to preserve total mechanical energy such as internal energy, kinetic energy and dissipative energy due to plastic deformation for long integration time. Finite element analysis of elasto-plastic stress waves is carried out in order to demonstrate the accuracy of the proposed algorithm.

  • PDF

Pressure Loss Analysis of the 75 kW MCFC Stack with Internal Manifold Separator (75 kW 용융탄산염 연료전지 (MCFC) 스택 내 압력 손실 해석)

  • Kim, Beom-Joo;Lee, Jung-Hyun;Kim, Do-Hyeong;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.367-376
    • /
    • 2008
  • To obtain the data of the pressure loss and differential pressure at the inside of the stack that was composed of 126 cells with 7,500 cm2 electrode area, 75kW molten carbonate fuel cell system has been operated. Computational fluid dynamics was applied to estimate reactions and thermal fluid behavior inside of the stack that was adopted with internal manifold type separator. The pressure loss coefficient K showed 72.29 to 84.01 in anode and 6.34 to 8.75 in cathode at low part of cells at the inside of 75 kW MCFC stack respectively. Meanwhile, the pressure loss coefficient of the higher part of cells at the interior of the stack showed 15.36 and 56.44 in anode and cathode respectively. These results mean that there is no big total pressure difference between anode and cathode at the inner part of 75 kW MCFC stack. This result will be reflected in 250kW MCFC system design.

The Clinical report of Asthmatic Patients with CVA by treatment of Homins Placenta Aqua-Acupuncture (뇌졸중을 동반한 천식 환자 자하거 약침 투여 2례)

  • Kim, Sung-Kyun;Han, Jong-Hyun;Shim, Yun-Seub;Lee, Jung-Hee;Kim, Eun-Gon
    • Journal of Pharmacopuncture
    • /
    • v.7 no.3
    • /
    • pp.123-129
    • /
    • 2004
  • Nowadays Asthma is considered to be an inflamatory disease characterized by airway hyperresponsiveness and pulmonary eosinophilia. Hominis Placenta is the dried placenta of a healthy women. It has correspondence to the meridians of lung and kindey. Hominis Placenta acupuncture therapy has effect on invigoration of vital energy nourishing blood and tonifying the essence. It can be applied to the disease as Asthma, pulmonary tuberculosis, chronic hepatitis, liver cirrhosis, degenerative change and cerebrovascular disease. We treated two patients of Asthma with CVA by Homins Placenta Aqua-Acupuncture. The effect of Homins Placenta Aqua-Acupuncture was assessed by analyzing the pulmonary function test(PFT) and Quality of Life Questionnaire for adult Korean Asthmatics(QLQAKA) in patients before and after treatment. Total score was increased. The patients are satisfied our treatment. But further research concerning this is still necessary.

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

A Study on Sasang Constitution Discrimination Using Body Biomarkers - Based on Korean Medicine Cohort Study (신체 생체 지표를 이용한 사상체질 판별 연구 - 한의 코호트 연구를 중심으로)

  • Park, Jeong-Su;Sung, Hyun Kyung;Shin, Seon Mi;Go, Ho-Yeon;Lee, Si-Woo;Baek, Younghwa
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.21-30
    • /
    • 2019
  • Objective : The study aimed to report the results of workplace-based Korean Medicine cohort, The cohort collected the health information including physical measurements, questionnaires, and biomarkers. Method : This study was conducted on 200 faculty members of two hospitals and two universities in 2017 through 2018. The study analyzed physical measurement, cold-heat questionnaire, body compositions and pulse characteristics. Result : The heat-cold score, waist circumference, visceral fat area, and body water were different according to the Sasang constitution, in order of Taeum > Soyang > Soeum. The pulse energy difference was shown only in women. Conclusion : There were differences in body composition such as heat point, waist circumference, internal fat area and body water content by constitution, and also difference by body mass in total energy in pulse examination. It is believed that there were significant relation between physical, physical and energy metabolic aspects through Sasang constitution.