• 제목/요약/키워드: Total harmonic distortion improvement

검색결과 37건 처리시간 0.025초

3상 3레벨 인버터의 중성점 제어를 이용한 고조파 왜율 저감 효과 (The effect of Harmonic Distortion Reduction on Three Phase Three level Inverter Using Neutral Point Control)

  • 김정규;양오
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.90-94
    • /
    • 2018
  • In this paper, we applied a three-level T-type inverter with the one more voltage level than two-level inverter. However, the three-level T-type inverter has a systematic problem with voltage unbalances. So neutral point control is essential. Therefore, the voltage unbalance problem of the three - phase inverter was confirmed to be controlled within 5V using the neutral point control algorithm in charge and discharge mode. In addition, total harmonic distortion was reduced in three phases (u phase, v phase, w phase) when neutral point control was performed in charging mode and also in three phases (u phase, v phase, w phase) in discharge mode. In this paper suggests a neutral point control algorithm to solve the voltage unbalance of a three-level T-type inverter, and shows the improvement of the performance of the proposed algorithm through experiment.

반복제어기를 적용한 단상 계통연계형 인버터의 전력품질 개선 (Improvement of Power Quality of Single-phase Utility Interactive Inverter using Repetitive Controller)

  • 김재한;목형수;최규하;이진우;정교범;이정민;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 2007
  • In recent years, installation of the new and renewable energy system is rapidly increasing. Because the new and renewable energy system is a practical distributed generation system to save energy resources and to keep environments clean. Conventional single-phase utility interactive inverter controls output current by using PI current controller. However, this method is insufficient to suppress harmonic current resulted from nonlinear loads in grid line. In this paper, in order to suppress periodic waveform distortion and improve THD(Total Harmonic Distortion), new type current controller added a parallel repetitive controller is proposed and then performance of the proposed controller was verified with computer simulation.

  • PDF

전동차용 전원장치의 출력전압 제어 안정성 향상 (Stability Improvement of Output Voltage Control on the Power Supply for Railways)

  • 서광덕
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.134-141
    • /
    • 1999
  • 본 논문은 전동차량용 전원장치의 출력전압 제어 안정성을 향상시키기 위한 연구이다. 입력전압 변동 및 부하 변동 등 과도상태시 출력 정전압 제어를 수행할 경우, L-C 필터부에서 공진이 발생함으로써 출력전압이 흔들리고 시스템이 불안해진다. 본 논문에서, 출력전압제어의 안정성을 확보하기 위해 주필터부에 공진을 억제하는 댐핑회로를 새롭게 제안하고, 이에 적합한 제어방법을 소개한다. 제안한 댐핑회로는 R-L로서 소형이고 간단히 구성된다. 제어기에는 과도상태분의 궤환제어와 대역저지필터를 적용한다. 또한 전력회로는 3레벨 PWM방식을 적용하였다. 이로서 과도상태에서 출력전압의 흔들림없이 변동폭을 10[%]이하로 제어할 수 있었으며, 정상상태의 출력 전압 왜형율도 3[%]이하로 감소시켰다.

  • PDF

8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정 (The THD measurement of HEP equipment power installed on 8200 series Electric locomotive)

  • 김대성;이경락;안홍관;박종천
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.488-497
    • /
    • 2010
  • 2001년 KORAIL에 도입된 8100대 신형 전기기관차는 독일 SIEMENS사의 BR152 모델을 국내 설정에 맞도록 들어와 부분 수정 및 보완 통하여, 2003년 8200대 신형 전기기관차를 탄생하도록 한 PROTOTYPE 이다. 8100대 신형전기기관차와 8200대 신형 전기기관차는 유사하지만, 일부 수정되고 개선된 부분 중의 하나가 객차 전원 공급(이하'HEP) 장치이다. 이에 본 논문은 8200대 신형 전기기관차의 HEP 장치에서 무궁화호 객차로 공급되는 HEP 전원의 고조파 왜율에 대하여 원제작사의 조합시험 결과를 바탕으로 현재 운용중인 KORAIL 8200대 신형 전기기관차의 HEP 전원의 고조파 왜율을 실측하여 상호 비교하고, 전원 공급 장치의 고조파 왜율에 대한 국제규격 및 현황을 설명하고자 한다.

  • PDF

PLL 기법을 이용한 단상 PWM 인버터의 정상상태 성능개선 (Steady-State Performance Improvement of Single-Phase PWM Inverters Using PLL Technique)

  • 정세교;이대식
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.356-363
    • /
    • 2004
  • 본 논문에서는 무정전 전원장치와 같이 일정전압 일정주파수(constant voltage and constant frequency; CVCF) 운전에 사용되는 단상 PWM 인버터의 정밀 전압제어 기법을 다루었으며 정상상태에서 전압 오차를 최소화하기 위해 phase-locked loop(PLL) 기법을 이용한 새로운 전압 제어 방법을 제안하였다. 제안된 제어기법에서는 출력 커패시터 전압과 전류를 이용하여 PLL 보상기를 구성하였으며 주제어기에 PLL 보상기를 추가하여 출력 전압의 정상상태 성능을 개선하였다. 제안된 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였으며, 그 결과 기존의 방법에 비해 정상상태 전압제어 성능과 Total Harmonic Distortion(THD)이 현저히 개선됨을 입증할 수 있었다.

Asymmetrical PWM for Harmonics Reduction and Power Factor Improvement in PWM AC Choppers Using Bee Colony Optimization

  • Sanjit, Panithi;Aurasopon, Apinan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.227-234
    • /
    • 2015
  • This paper presents the application of bee colony optimization (BCO) to obtain the optimal switching angles for single phase PWM AC choppers. The optimal switching angles are found in the region of 0-${\pi}$ based on the asymmetrical PWM technique. This PWM process results in improvements of the total harmonic distortion of the output voltage and in the input power factor. Simulation and experimental results are compared with the conventional PWM to verify the performance of the proposed PWM process.

Improvement of Input Current Waveform for Soft-Switching Boost DCM Converter with Unity Power Factor

  • Taniguchi K.;Watanabe T.;Morizane T.;Kimura N.;Lee Hyun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.556-560
    • /
    • 2001
  • In this paper, a soft-switching discontinuous mode (DCM) power factor corrected (PFC) converter is analyzed by applying the double Fourier series expansion. It is found that the fundamental component and higher-order harmonics included in the input current waveform are obtained by the Fourier series expansion of the mean value of the inductor current. From the theoretical analysis, a new method removing the distortion of the input current waveform is proposed. In spite of an open loop system, the proposed method makes a great improvement of the total harmonic distortion even if the ratio of output voltage to input voltage is very low.

  • PDF

CCFL유도등의 전기적 특성 분석 (Analysis of Electrical Characteristics of CCFL Exit Light)

  • 정종진
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.184-193
    • /
    • 2021
  • 연구목적: 본 연구에서는 CCFL유도등의 동작원리가 일반 조명기기와 동일하여 일반 조명기기의 램프 안정기 성능인증 기준인 KS기준에서 광원의 특성에 영향을 줄 수 있는 시험항목을 도출하여 CCFL유도등의 특성을 분석하였다. 또한 CCFL광원의 전기적 특성과 온도 특성의 연관성을 분석하여 광원 수명에 미치는 영향을 고찰하였다. 연구방법: 실험에 사용된 시료는 대형, 중형, 소형 등 각 크기별 2개 제조사의 제품을 대상으로 수행하였으며, 시험 항목은 역률, 파고율, 전류 고조파함유율이다. 연구결과: 역률은 모든 시료가 0.4~0.6사이의 값을 나타내어 KS기준에서 정한 0.9이상 보다 작은 값을 보였다. 파고율은 대형의 경우 3.6~3.7 정도의 값을 나타냈으며, 중형은 4.4~4.7, 소형은 3.5~3.7사이의 값을 나타내었다. KS기준인 1.7이하보다는 2배 이상의 높은 값을 나타냈다. 전류 고조파함유율은 81%~110%의 값을 나타냈으며, KS기준이 20% 이하임을 감안할 때 모든 시료가 KS기준을 상당히 넘어서는 값을 가짐을 확인할 수 있었다. 결론: 파고율과 전류 고조파함유율은 광원의 온도상승과 기기의 소손 등에 영향을 미칠 가능성이 있는 성분이므로 이런 전기적 특성을 KS기준의 범위 안에서 유도등을 개발한다면 유도등의 품질개선과 유지관리에 큰 도움이 되리라 생각된다.

가변형 수동 고조파 필터에 의한 단상 무정전전원장치의 고조파 저감에 관한 연구 (A Study on Harmonic Reduction of Single-phase UPS with Variable Passive Harmonic Filters)

  • 김성삼;황선환
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.495-501
    • /
    • 2019
  • 본 논문에서는 정류 브리지 다이오드를 갖는 단상 무정전전원장치의 전원측 고조파 및 역률 개선을 위한 가변형 고조파 필터를 제안한다. 2레벨 이상의 전력변환방식을 적용한 무정전전원장치는 전원측 고조파 및 역률 특성이 우수한 반면, 전 브리지 방식의 무정전전원장치는 전원측에 제 3고조파, 제 5고조파, 제 7고조파 및 역률 저하를 심각하게 야기한다. 이에 따라 단상 전 브리지 동작에 의해 야기된 (2n+1)차 고조파 제거 및 역률 개선을 위한 가변형 고조파 필터를 제안하고자 한다. 제안한 가변형 고조파 필터의 성능을 평가하기 위해 다양한 시뮬레이션과 실험을 진행하여 타당성을 검증하였다.

단상 Three-level boost converter의 역률개선 (Power Factor Improvement of Single-Phase Three-level Boost Converter)

  • 서영조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF