• Title/Summary/Keyword: Total Thermal Resistance

Search Result 122, Processing Time 0.031 seconds

Analysis of the thermal management of a high power LED package with a heat pipe

  • Kim, Jong-Soo;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.96-101
    • /
    • 2016
  • The thermal management of high-power LED components in an assembly structure is crucial for the stable operation and proper luminous function. This study employs numerical tools to determine the optimum thermal design in LEDs with a heat sink consisting of a crevice-type vapor-chamber heat pipe. The effects of the MCPCB are investigated in terms of the substrate thicknesses on which the LEDs are mounted. Further, different placement configurations in a system module are considered. This study found that for a confined area, a power of 40 W/LED is applicable to a high-power package. Furthermore, the thermal conductivity of dielectric layer materials should ideally be greater than 0.9 W/m.K. The temperature conditions of the vapor chamber in a heat pipe greatly affect the thermal performance of the system. At an offset distance of 9.0 mm and a $2^{\circ}C$ increase in the temperature of the heat pipe, the resulting maximum temperature increase is approximately $1.9^{\circ}C$ for each heat dissipation temperature. Finally, at a thermal conductivity of 0.3 W/m.K, it was found that the total thermal resistance changes dramatically. Above 1.2 W/m.K, the resistance change reduces exponentially.

NUMERICAL STUDY ON THE EFFECT OF THE SHAPE OF THE HEAT TRANSFER PLATE ON THE THERMAL PERFORMANCE OF THE RADIATOR (변압기용 방열기의 방열판 형상이 방열특성에 미치는 영향에 관한 수치적 연구)

  • Kim, Y.J.;Doo, J.H.;Ha, M.Y.;Son, S.W.;Kim, J.K.;Lee, S.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.65-76
    • /
    • 2015
  • In this study, the natural convection phenomenon of the air side and the forced convection phenomenon of the oil side were simulated in the radiator through a 3-D numerical analysis, and the total heat released by the oil side into the radiator heating plate and then to the air side was evaluated. Also, a quantitative analysis was carried out on the effect of each thermal resistance on the overall heat transfer coefficient through a 1-D thermal circuit analysis on the heat transfer mechanisms of the radiators considered in this study. In addition, for the diverse shapes of the heating plates considered in this study, the pressure drops of the oil side were quantitatively compared and evaluated. The temperatures at the air side and the oil side outlets of the radiators with 8 different fin shapes considered in this study had almost similar values showing a difference of +/-3% and, accordingly, the total heat transfer also showed similar heat dissipation performance in all the models. As a result of the 1-D thermal circuit analysis, in all the models considered in this study, while the thermal resistance of the air side accounted for 92% to 96% of the total, that of the oil side was 5 to 7%, and that of the heating plate showed a very small value of 0.02%.

An Ananlysis on the Clothing Pracices between Seoul and yanbian -Focusing on the clothing weight- (서울.연변간 착의실태 조사분석 -착의량을 중심으로-)

  • Oh, Soon;Lee, Won-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.1019-1029
    • /
    • 1999
  • In order to find out the influences upon not only the thermal resistance of human body but also the clothing action and the clothing weight which are caused by the differences in the thermal living conditions by using air conditioner and so on to adapt themselves to the changes of their residential environment according to the changes of seasons we investigated the clothing practices upon the male and female students in Seoul and Korean male and female students in Yanbian who are estimated to have different thermal living conditions in spite that they are same folk as well as living in the same age. 1. The total clothing weight of body surface erea was increased in order of summer autumn spring and winter seasons and by seasons the changes of the clothing weight were found in both areas, In Seoul the changes of upper outwear clothing weight were found on both sexes but in Yanbian the changes of underwear weight were found on both sexes. And the underwear weight of both sexes in Seoul was lighter than that of both sexes in Yanbian. 2. Those in Seoul tended to fell colder in winter and hotter in summer than those in Yanbian on account that the formers are more sensitive of thermal conditions than the latters. 3. Comparing clo-value claculated by the fomula of with the Winshlow's clo-value those in Yanbian had higher thermal resistance than those in Seoul. Consequently those in Seoul adapted thermselves to the seasons by controling the upper outwear weight but those in Yanbian did it with underwear weight, The male and female students in Seoul tended to feel colder in winter and hotter in summer than hose in Yanbian because the thermal sense of the former is more sensitive than that of the latter.

  • PDF

A Study on the Performance Characteristics of a Heat Pipe Combined with PCM (상변화 물질을 조합한 히트파이프의 성능 특성에 관한 연구)

  • Park, Young-Hark;Jung, Eui-Guk;Boo, Joon-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2119-2123
    • /
    • 2007
  • This study deals with performance characteristics of heat pipe combined with a solid-liquid phase change material(PCM). The outer diameter of the heat pipe was 9.5 mm and the total length was 600 mm, where the evaporator, the adiabatic section and the condenser lengths were equally 200 mm. A paraffin wax having a melting point of 58.5$^{\circ}C$ was used as PCM. The paraffin container was attached to the adiabatic section of the heat pipe. The paraffin container had outer diameter of 18 mm, wall thickness of 1.2 mm and the total length of 100 mm. The heat pipe was tested with tilt angle of horizontal degree and favorite angle 10 degree, with evaporator lower position to provide stable operation of the heat pipe. Input thermal load was varied from 40 W, with increment of 40 W, to above 100 W until the maximum temperature of the heat pipe wall reached 200$^{\circ}C$. Test results of the PCM heat pipe were presented in comparison with conventional heat pipe of the same basic dimensions. The performance was analyzed in terms of temperature distribution, thermal resistance and heat transport capability.

  • PDF

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

Development and Performance Evaluation of Body Armor for Wear Comfort Enhancement (착용쾌적성이 향상된 방탄복 개발과 성능평가)

  • Kim, Soyoung;Lee, Yejin;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.10
    • /
    • pp.1050-1057
    • /
    • 2012
  • This study helps develop a cool body armor that maintains a tight-fit configuration to the body surface and evaluates the performance of newly developed body armor in a wear test. Three types of body armor were used for evaluation. One was a tight fitting body armor that was constructed to improve the degree of fit and ease of movement for Korean soldier using 3D technology. Another was ventilating body armor with attached spacers on the shoulder to reduce the thermal stress on the soldier. The third was a prevailing body armor produced by a Korean body armor company. In order to evaluate the performance of the body armor, a human wear test, a thermal mannequin test, and computational fluid dynamics (CFD) were executed. Five subjects participated in the wear test. Subjective wear sensation, total amount of sweat and dynamic change of clothing microclimate were observed during and after exercise on a treadmill; subsequently, it was found that subjects rated tight fitting body armor and ventilating body armor lighter, drier, and easier to move than the conventional body armor (p<.05). Total amount of sweat was the least in the case of ventilating body armor. The thermal resistance and vapor resistance of the ventilating body armor were improved remarkably. In addition, the skin temperature of the ventilating body armor with spacers was lower than the tight fitting body armor by at least $1^{\circ}C$ in the CFD result. It is noted that thermal-wet comfort of the 3D body armor with ventilating feature is superior to the conventional body armor, especially when the ventilating channel is not closed due to a backpack.

Evaluation of Physical, Mechanical Properties and Pollutant Emissions of Wood-Magnesium Laminated Board (WML Board) for Interior Finishing Materials

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.86-94
    • /
    • 2020
  • This study serves as basic research for the development of a new wood-based building finishing material that improved the weakness of inorganic materials such as gypsum board and magnesium board widely used as interior finishing materials and brought out the strength of the wood. The results of evaluating the physical and mechanical properties and the environmental effect related to hazardous substance discharge having manufactured a wood-magnesium laminated composite are as follows. The thermal conductivity and thermal resistance of WML board was improved by about 28~109 percent over magnesium board due to the low thermal conductivity of wood. The adhesive strength of WML board showed a similar result to that of plywood as it exceeds 0.7N/㎟, the adhesive standard of wood veneer which is presented by KS F 3101. Bending strength and screw holding strength were more improved by manufacturing WML board than magnesium board. The WML board manufactured in this study satisfied the criteria for emissions of hazardous substances prescribed in the Indoor Air Quality Control Act, and confirmed the possibility of development as a new wood-based composite material that can replace existing inorganic materials.

Carbon Nanotube Heater Generating High Heat Flux

  • Kang, Yong-Pil;Lee, Hyun-Chang;Kim, Duck-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.530-530
    • /
    • 2012
  • Many practical applications of carbon nanotubes(CNTs) have been proposed and there have been attempts to utilize CNT films as transparent electrodes for solar cells and displays. Our group has considered the use of the CNT film as a thin film heater (TFH) and proposed it for the first time and reported the thermal behavior of the TFH made of single walled CNTs. However, due to the relatively high electrical resistance of the CNT film, using the TFH in application areas requiring high heat flux has been a difficult problem. To overcome this obstacle, we adopted a 'branch electrodes' concept to increase the film conductance dramatically. If two branch electrodes are inserted into a TFH whose original electrical resistance is R, the total resistance will be reduced to R/9. Because of the increased aspect ratio, the resistance of each segmented TFH will be reduced to R/3. Furthermore, since they are connected in parallel, the total resistance reduces to R/9. This could be extended to n branch electrodes, and the total resistance of the film will be reduced to R/(n+1)2, if the resistance of electrodes are negligibly small. We fabricated the heaters with different number of branch electrodes. The number of branch electrodes of the fabricated heaters are 0, 2, 4, 8 and their electrical resistance are 101.4, 39.5, 20.0, $15.4{\Omega}$, respectively. We applied 20V to each heater and monitored the temperature variations. We could achieve high heating temperature even with low voltage supply. This technique could be applied to relevant industrial applications which need high power film heater.

  • PDF

Heat Conduction Analysis of Metal Hybrid Die Adhesive Structure for High Power LED Package (고출력 LED 패키지의 열 전달 개선을 위한 금속-실리콘 병렬 접합 구조의 특성 분석)

  • Yim, Hae-Dong;Choi, Bong-Man;Lee, Dong-Jin;Lee, Seung-Gol;Park, Se-Geun;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.342-346
    • /
    • 2013
  • We present the thermal analysis result of die bonding for a high power LED package using a metal hybrid silicone adhesive structure. The simulation structure consists of an LED chip, silicone die adhesive, package substrate, silicone-phosphor encapsulation, Al PCB and a heat-sink. As a result, we demonstrate that the heat generated from the chip is easily dissipated through the metal structure. The thermal resistance of the metal hybrid structure was 1.662 K/W. And the thermal resistance of the total package was 5.91 K/W. This result is comparable to the thermal resistance of a eutectic bonded LED package.

Optimal flammability and thermal buckling resistance of eco-friendly abaca fiber/ polypropylene/egg shell powder/halloysite nanotubes composites

  • Saeed Kamarian;Reza Barbaz-Isfahani;Thanh Mai Nguyen Tran;Jung-Il Song
    • Advances in nano research
    • /
    • v.16 no.2
    • /
    • pp.127-140
    • /
    • 2024
  • Upon direct/indirect exposure to flame or heat, composite structures may burn or thermally buckle. This issue becomes more important in the natural fiber-based composite structures with higher flammability and lower mechanical properties. The main goal of the present study was to obtain an optimal eco-friendly composite system with low flammability and high thermal buckling resistance. The studied composite consisted of polypropylene (PP) and short abaca fiber (AF) with eggshell powder (ESP) and halloysite clay nanotubes (HNTs) additives. An optimal base composite, consisting of 30 wt.% AF and 70 wt.% PP, abbreviated as OAP, was initially introduced based on burning rate (BR) and the Young's modulus determined by horizontal burning test (HBT) and tensile test, respectively. The effects of adding ESP to the base composite were then investigated with the same experimental tests. The results indicated that though the BR significantly decreased with the increase of ESP content up to 6 wt.%, it had a very destructive influence on the stiffness of the composite. To compensate for the damaging effect of ESP, small amount of HNT was used. The performance of OAP composite with 6 wt.% ESP and 3 wt.% HNT (OAPEH) was explored by conducting HBT, cone calorimeter test (CCT) and tensile test. The experimental results indicated a 9~23 % reduction in almost all flammability parameters such as heat release rate (HRR), total heat released (THR), maximum average rate of heat emission (MARHE), total smoke released (TSR), total smoke production (TSP), and mass loss (ML) during combustion. Furthermore, the combination of 6 wt.% ESP and 3 wt.% HNT reduced the stiffness of OAP to an insignificant amount by maximum 3%. Moreover, the char residue analysis revealed the distinct differences in the formation of char between AF/PP and AF/PP/ESP/HNT composites. Afterward, dilatometry test was carried out to examine the coefficient of thermal expansion (CTE) of OAP and OAPEH samples. The obtained results showed that the CTE of OAPEH composite was about 18% less than that of OAP. Finally, a theoretical model was used based on first-order shear deformation theory (FSDT) to predict the critical bucking temperatures of the OAP and OAPEH composite plates. It was shown that in the absence of mechanical load, the critical buckling temperatures of OAPEH composite plates were higher than those of OAP composites, such that the difference between the buckling temperatures increased with the increase of thickness. On the contrary, the positive effect of CTE reduction on the buckling temperature decreased by raising the axial compressive mechanical load on the composite plates which can be assigned to the reduction of stiffness after the incorporation of ESP. The results of present study generally stated that a suitable combination of AF, PP, ESP, and HNT can result in a relatively optimal and environmentally friendly composite with proper flame and thermal buckling resistance with no significant decline in the stiffness.