• Title/Summary/Keyword: Total Ionizing Dose

Search Result 73, Processing Time 0.032 seconds

The Study on the Design and Implementation of SHF band Low Noise Amplifier of Digital Satellite Communication (디지털 위성 중계기용 SHF 대역 저잡음 증폭장치 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1159-1164
    • /
    • 2016
  • This study describes the design and implementation of SHF band Low Noise Amplifier of Digital Satellite Communication. We have applied to HEMT part to minimize Noise Figure of system. and minimized the potential for the occurrence of such erroneous operation of equipment through the simulations of the space environment. We designed a reliable Low Noise Amplifier through simulation for a TID according to the vibration generated during the launch and space radiation environment, and compared pre-simulation of main performance results to test results about main performances of Low Noise Amplifier after production.

A high energy radiation evaluation test of the 74AC04 Hex Inverter (고준위 감마방사선 환경에서의 원격계측을 통한 74AC04 의 내방사선 영향평가 및 분석)

  • Oh, Seung-Chan;Lee, Hyun-Jin;Lee, Nam-Ho;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1788_1789
    • /
    • 2009
  • 본 논문에서는 핵폭발과 같은 고준위방사선환경에서의 전자부품소자의 피해평가분석을 통하여 군용전자장비의 내방사선화를 하기 위한 기반기술의 확립을 위한 연구의 일환으로 74AC04(Inverter) IC에 대한 고준위감마선조사시험을 통하여 Co-60 Gamma-ray 선원을 사용하여 총 400Krad[si] 누적 선량에 대한 74AC04 소자의 동작특성 및 전기적 파라메터의 변화분석을 진행하였다. 시험평가 방법 및 절차는 MIL-STD-883G 1019.7[1] 및 ESA/SCC Basic Specification No.22900[2] 절차를 기준으로 하여 동일 lot에 대한 5개의 샘플을 이용하여 동작특성에 영향을 미치는 주요한 전기 적파라메터인 정지소비전류, 입력누설전류, VIL(Maximum Low Level Input Voltage)에 대한 변화추이를 분석하였다. 이번 조사시험을 통하여 입력게이트에서의 누적선량에 따른 TID(Total Ionizing Dose) 효과로 인한 VIL의 감소 추이를 확인 할 수 있었으며 총 누적선량 160Krad 이상에서의 VIL은 허용기준치이하로 감소하였고 정지소비전류의 경우 누적선량에 따른 점진적 증가 현상과 200Krad부근에서의 설계스펙허용치를 초과하는 결과를 확인하였다.

  • PDF

The Study on the Design and Implementation of SHF band Upconverter of Digital Satellite Communication (디지털위성중계기용 SHF 대역 상향주파수 변환장치 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.261-266
    • /
    • 2017
  • This study describes the design and implementation of SHF band Upconverter Digital Satellite Communication. The SHF band Upconverter unit consists of PLDROand frequency converter. In frequency converter, microstripBPF and LPF designed through the pre EMsimulation are implemented to minimize the unwanted spurious in frequency converter. Through the pre-simulation analysis ofspace environment, the possibility of and minimized about the malfunction of equipment and we designed a reliable SHF band Upconverter through simulation for a TID according to the vibration generated during the launch and space radiation environment, and compared pre-simulation of main performance results to test results about main performances of SHF band Upconverter after production.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.

The Study on the Implementation and Design of Power Supply Unit of Digital of Dehop/Rehop Transponder of EQM (우주 인증용 대전자전중계기의 전원공급기 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.437-442
    • /
    • 2021
  • This study describes the design and implementation of power supply of dehop/rehop transponder of EQM(Engineering Qualification Model). We materialized the interface of the PLDIU and power supply of a satellite bus, and minimized the potential for the occurrence of such erroneous operation circuit ESD through the WCA of the space environment. We designed a reliable power supply through simulation for TID about space radiation and simulation of the vibration generated during it launched, and we confirmed that it satisfies the environmental test specification through the test space environment after production.

Towards defining a simplified procedure for COTS system-on-chip TID testing

  • Di Mascio, Stefano;Menicucci, Alessandra;Furano, Gianluca;Szewczyk, Tomasz;Campajola, Luigi;Di Capua, Francesco;Lucaroni, Andrea;Ottavi, Marco
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1298-1305
    • /
    • 2018
  • The use of System-on-Chip (SoC) solutions in the design of on-board data handling systems is an important step towards further miniaturization in space. However, the Total Ionizing Dose (TID) and Single Event Effects (SEE) characterization of these complex devices present new challenges that are either not fully addressed by current testing guidelines or may result in expensive, cumbersome test configurations. In this paper we report the test setups, procedures and results for TID testing of a SoC microcontroller both using standard $^{60}Co$ and low-energy protons beams. This paper specifically points out the differences in the test methodology and in the challenges between TID testing with proton beam and with the conventional gamma ray irradiation. New test setup and procedures are proposed which are capable of emulating typical mission conditions (clock, bias, software, reprogramming, etc.) while keeping the test setup as simple as possible at the same time.

Simulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications

  • Gandha Satria Adi;Dong-Seok Kim;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.568-574
    • /
    • 2024
  • The development of radiation-tolerant radio-frequency (RF) systems can be a solution for applications in extreme radiation environments, such as nuclear power plant monitoring and space exploration. Among the crucial components within an RF system, the low noise amplifier (LNA) stands out due to its vulnerability to TID effects, mainly relying on transistors as its main devices. In this study, the TID effects in the LNA using standard 0.18 ㎛ complementary metal oxide semiconductors (CMOS) technology are estimated and analyzed. The results show that the LNA can withstand absorbed radiation up to 100 kGy. The S21, S11, noise figure (NF), stability (K), and linearity of the third input intercept point (IIP3) slightly shifted from the initial values of 0.8312 dB, 0.793 dB, 0.00381 dB, 1.34406, and 2.36066 dBm, respectively which are still comparable to the typical performances. Moreover, the standard 0.18 ㎛ technology has demonstrated its radiation tolerance, as it exhibits negligible performance degradation in the conventional LNA even when exposed to radiation levels up to 100 kGy. In this context, simulation approach offers a means to predict the TID effects and estimate the radiation exposure limit for electronic devices, particularly when transistors are used as the primary RF components.

Effect of lonizing Radiation on the Host Resistance Against Listeria Monocytogenes Infection and the Cytokine Production in Mice (방사선조사후 마우스에서의 Cytokine 생산능 및 Listeria monecytogenes에 대한 저항성의 변화)

  • Oh, Yoon-Kyeong;Chang, Mee-Young;Kang, In-Chol;Oh, Jong-Suk;Lee, Hyun-Chul
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.175-186
    • /
    • 1997
  • Purpose : To evaluate the qualitative immunologic changes by ionizing radiation. we studied the altered capacities of the macrophages and lymphocytes to produce cytokines in conjunction with resistance to Listeria monocytegenes (LM) infection in mice Materials and Methods : BALB/c mice and Listeria monocytogenes were used. The mice were infected intraperitoneally with $10^5LM$ at 1 day after irradiation (300cGy) and sacrificed at 1, 3, 5 days after infection, and then the numbers of viable LM per spleen in the irradiated and control group were counted. Tumor necrosis factor-alpha ($TNF-\alpha$), interferon-gamma ($IFN-\gamma$). interleukin-2 (IL-2), and nitric oxide (NO) were assessed after irradiation. Results : Under gamma-ray irradiation with a dose range of 100-850cGy, the number of total splenocytes decreased markedly in a dose-dependent manner, while peritoneal macrophages did so slightly Cultured peritoneal macrophages produced more $TNF-\alpha$ in the presence of lipopolysaccharide (LPS) during the 24 hours after in vitro irradiation, but their capacity of $TNF-\alpha$ Production showed a decreased tendency at 5 days after in vivo total body irradiation. With 100cGy and 300cGy irradiation, cultured peritoneal macrophages produced more NO in the presence of LPS during the 24 hours after in vitro irradiation than without irradiation. Activated splenocytes from irradiated mice (300cGy) exhibited a decreased capacity to Produce IL-2 and $IFN-\gamma$ with Concavalin-A stimulation at 3 days after irradiation. When BALB/c mice were irradiated to the total body with a dose of 300cGy, they showed enhanced resistance during early innate phase, but a significant inhibition of resistance to LM was found in the late innate and acquired T-cell dependent phases. Conclusion : These results su99es1 that increased early innate and decreased late innate and acquired immunity to LM infection by ionizing radiation (300cGy) may be related to the biphasic altered capacity of the macrophages to produce $TNF-\alpha$ and the decreased capacities of the lymphocytes to produce IL-2 and $IFN-\gamma$ in addition to a marked decrease in the total number of cells.

  • PDF

Effects of whole-body gamma-irradiation on the peripheral blood of ICR mouse (ICR 마우스에서 방사선 조사 용량에 따른 혈액변화의 관찰)

  • Kim, Sung-Ho;Lee, Jong-Hwan;Kim, Se-Ra;Lee, Hae-June;Lee, Yun-Sil;Kim, Tae-Hwan;Ryu, Si-Yun;Jo, Sung-Kee;An, Mi-Yeong
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.2
    • /
    • pp.183-190
    • /
    • 2002
  • The effects of ionizing radiation on the peripheral blood elements of ICR mouse were examined after varying doses of whole-body gamma-irradiation. ICR mice (n=50) were exposed to 0, 2, 4, 6 and 8 Gy gamma-ray ($^{60}Co$) at 10 Gy/min. The animals were studied for their hematological response on days, 3, 7, 14, 21, 42 and 56 post irradiation. No significant change was noted in erythrocyte, hemoglobin and hematocrit values after irradiation with dose of 2 Gy. Decreasing erythrocyte, hemglobin and hematocrit values occured after irradiation with doses of more than 4 Gy on day 7 after irradiation followed by a sharp fall on day 14. A recovery in these values was noted after 3 weeks of irradiation. Thrombocyte counts decreased on day 3, reaching minimal values on day 7. The total number of leukocytes was reduced on day 3, mainly because of a decrease in the lymphocyte population. An evident lymphopenia and neutropenia occur almost on the day 3 and last up to the day 28 after irradiation. All of the hematological values decreased in the blood in a dose-dependent manner at the same time.

Effects of External Whole-Body gamma-Irradiation on Blood Picture and Growth in Young Rabbits (Cobalt-60 gamma 선(線) 외부전신조사(外部全身照射)가 어린 토끼의 혈액상(血液像)과 성장률(成長率)에 미치는 영향(影響))

  • Sung, Jai Ki
    • Korean Journal of Veterinary Research
    • /
    • v.13 no.1
    • /
    • pp.85-102
    • /
    • 1973
  • In the event a population of animals is exposed to ionizing radiation, proper disposition of animals will minimize loss to the farmer and protect the public from unwholesome meat and dairy products. Clinical response is an important factor in considering salvage of animals for food following exposure to ionizing radiation whether the dose is lethal or not. It is the purpose of this report to present the discussions of blood picture and growth of y ung growing rabbits exposed to cobalt-60 gamma-irradiation. The experimental animals were Hyrnalayan rabbits of 65 days old. The body weight for all animals of the time of irradiation was approximately 450g. The 96 rabbits used in the experiment were allotted t groups of eight. Rabbits in one group served as controls and the others were exposed to single doses of 100, 200, 300, 400, 500, 600 and 700 Roentgens (R). The exposure does rate averaged 15 R per minute. Central blood was obtained by heart puncture. Erythrocyte and leukocyte enumerations and, determinations of hemoglobin in blood and hematocrit value were made in the usual manner. Erythrocyte counts, concentrations of hemoglobin in blood, and hematocrit readings dropped to the lowest value between 1 and 4 weeks postirradiation, returning towards the control values. But recovery was not complete at the time of the last determination on 6 weeks postirradiation. There was a progressive decrease with increasing radiation does in the above values. Mean corpuscular volume, mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration were not affected by the irradiation. After irradiation of each does the numbers of total leukocyte and the absolute numbers of various types of white cell began to decrease rapidly, and reached a minimum after 2 weeks, returning towards normal levels. But recovery was not complete at the time of the last determination on 6 weeks postirradiation. The reductions in total leukocyte and differential counts as the radiation does increases were apparent. Relative neutrophilia was observed in each irradiated group because of more expense of lymphocytes after irradiation. Growth rate of the rabbits was not affected by 100 R of whloe-body irradiation, while rabbits irradiated with 200, 300, 400 and 500 R showed marked depression of growth rate. As the radiation does increases, a depression of growth rate was apparent. The rabbits exposed to 600 and 700 R ceased from growing and recovery was not recognized during the experimental period.

  • PDF