• 제목/요약/키워드: Total Flow Control

검색결과 584건 처리시간 0.031초

Preliminary Studies on Double-Diffusive Natural Convection During Physical Vapor Transport Crystal Growth of Hg2Br2 for the Spaceflight Experiments

  • Ha, Sung Ho;Kim, Geug Tae
    • Korean Chemical Engineering Research
    • /
    • 제57권2호
    • /
    • pp.289-300
    • /
    • 2019
  • We have conducted a preliminary numerical analysis to understand the effects of double-diffusive convection on the molar flux at the crystal region during the growth of mercurous bromide ($Hg_2Br_2$) crystals in 1 g and microgravity (${\mu}g$) conditions. It was found that the total molar fluxes decay first-order exponentially with the aspect ratio (AR, transport length-to-width), $1{\leq}AR{\leq}10$. With increasing the aspect ratio of the horizontal enclosure from AR = 1 up to Ar = 10, the convection flow field shifts to the advective-diffusion mode and the flow structures become stable. Therefore, altering the aspect ratio of the enclosure allows one to control the effect of the double diffusive natural convection. Moreover, microgravity environments less than $10^{-2}g$ make the effect of double-diffusive natural convection much reduced so that the convection mode could be switched over the advective-diffusion mode.

Enhancement of the nucleation density for diamond film on the pretreated glass substrate by the application of cyclic modulation of the source-gas flow rate

  • Kim, T.-G.;Kim, S.-H.;Kim, Y.-H.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제4권1호
    • /
    • pp.18-22
    • /
    • 2000
  • For the enhancement of the nucleation density of the diamond film, we introduced the cyclic process. The cyclic process was carried out by the on/off control of CH$_4$ flow rate for a relatively short time (10 min), compared with the total reaction time (6 h). Prior to depositing the diamond film, we made the pretreated glass substrate via the unidirectional scratch using ∼l $\mu\textrm{m}$ size diamond powders. Diamond films were deposited on the pretreated glass substrate in a microwave plasma enhanced chemical vapor deposition (MPECVD) system. We observed the enhancement of the nucleation density of the diamond films caused by the cyclic process. Detailed surface morphologies of the substrate were investigated after the cyclic process. Based on these results, we discussed the cause for the enhancement of the nucleation density on the pretreated glass substrate by the cyclic process.

  • PDF

철로 역사에서 발생 가능한 비점오염물질의 특성 및 관리방안 (Characteristics and Control of Nonpoint Pollutants in Railway Station)

  • 어성욱;김이형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1695-1700
    • /
    • 2004
  • Nonpoint pollutants were monitored on railway station land use. Lots of pollutant mass were washed-off in a first hour. The 95$\%$ confidence interval of pollutant concentrations ranges from 61.6 to 115.4 mg/L for TSS(mean= 88.50 mg/L). 103.8$\∼$244.1 mg/L for COD(mean= 174 mg/L) and 7.68$\∼$17.32 mg/L for Oil & Grease(mean= 12.5 mg/L). The various metals were also washed-off during storm runoff from railway station. The ranges of 95$\%$ confidence intervals were 39.2$\∼$84.0 ug/L for total Cu(mean= 61.6 ug/L), 14.0 $\∼$ 25.8 ug/L for total Pb(mean= 19.9 ug/L) and 182.2 $\∼$ 376.1 ug/L for total Zn(mean= 279.2 ug/L). As a result of this research, we concluded that up to 50$\%$ of the total pollutant mass can be removed when first 30$\%$ of the total flow are treating, and it can be a first flush criteria for best management practices.

  • PDF

승용차 외장측면거울 주위의 유동 특성 (Wake Flow Characteristics around the Side Mirror of a Passenger Car)

  • 한용운;김정현;황인호;서정복;임병훈;정의헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2573-2578
    • /
    • 2007
  • In order to investigate the vortex body frame interaction around the side mirror of a passenger car, velocity vector fields in the wake, pressure distributions and boundary layer flows over both the mirror surface and the mirror housing, have been measured by several experimental tools. It was resulted that only within an half downstream distance of the mirror span there appears the recirculation zone, and also found that vortex trail towards to the driver side window between A and B pillars, making the acoustic noise and vibration. Wake vortex rolls up after this recirculating zone and makes the trail of the vortex center towards the driver side window, which was also confirmed by measurements of wake velocity vectors in the vertical sections of the trail and visualization over the side mirror surfaces as well. It was also observed that total pressure distribution over the mirror surface has the minimum peak near the lower tip region which can be considered as the origin of the vortex center. It can be concluded that the geometrical modification of the lower tip and the upper root area of the mirror housing is the key to control the wake vortex.

  • PDF

Influence of ground pumice powder on the bond behavior of reinforcement and mechanical properties of self-compacting mortars

  • Benli, Ahmet;Karatas, Mehmet;Sastim, M. Veysel
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.283-290
    • /
    • 2017
  • The aim of this study is to investigate the effect of the bond strength of self-compacting mortars (SCMS) produced from ground pumice powder (GPP) as a mineral additive. In this scope, six series of mortars including control mix were prepared that consist of 7%, 12%, 17%, 22% and 27% of ground pumice powder by weight of cement. A total of 54 specimens of $40{\times}40{\times}160mm$ were produced and cured at the age of 3, 28 and 90-day for compressive and tensile strength tests and 18 specimens of $150{\times}150{\times}150mm$ mortar were prepared and cured at 28 days for bond strength tests. Flexural tensile strength and compressive strength of $40{\times}40{\times}160mm$ specimens were measured at the curing age of 7, 28 and 90-day. Mini V-funnel flow time and mini slump flow diameter tests were also conducted to obtain rheological properties. As a result of the study, it was observed that the SCMs containing 12% of GPP has the highest bond strength as compared to control and GPP mortars. Compressive strength slightly increased up to 12% of GPP.

원료및 제품저장조를 포함하는 병렬 비연속 공정의 최적설계 (Optimal design of parallel noncontinuous units with feedstock/product storages)

  • 이경범
    • 제어로봇시스템학회논문지
    • /
    • 제3권5호
    • /
    • pp.532-541
    • /
    • 1997
  • This article derives an analytic solution to determine the optimal size of multiple noncontinuous process and storage units. The total cost to be minimized consists of the setup cost of noncontinuous processing units and the inventory holding cost of feedstock/product storages. A novel approach, which is called PSW(Periodic Square Wave) model, is applied to represent the material flow among non-continuous units and storages. PSW model presumes that the material flow between unit and storage is periodic square wave shaped. The resulting optimal unit size has similar characteristics with the classical economic lot sizing model such as EOQ(Economic Order Quantity) or EPQ(Economic Production Quantity) model in a sense that the unit size is determined as the balance between setup and inventory holding cost. However, the influence of inventory holding cost of PSW model is different from that of EOQ/EPQ model. EOQ/EPQ model includes only the product inventory holding cost but PSW model includes all inventory holding costs around the non-continuous unit with proportional contribution. PSW model is suitable for analyzing interlinked process-storage system. The optimal lot size of PSW model is smaller than that of EOQ/EPQ model. This is quitea remarkable result considering that the EOQ/EPQ model has been is widely used since last half century.

  • PDF

비정상 압축파와 비정상 팽창파의 간섭에 관한 수치해석적 연구 (Numerical study on the interaction between unsteady compression and unsteady expansion wave)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1413-1421
    • /
    • 1997
  • A new control method to alleviate the impulsive noise at the exit of high-speed railway tunnel was applied to the compression wave at the entrance of the tunnel. This method uses the interaction phenomenon of unsteady expansion wave and unsteady compression wave. Unsteady expansion wave was assumed to be made instantaneously by the simple theory of shock tube. Total Variation Diminishing method was employed to solve the axisymmetric unsteady compressible flow field with a specified compression wave. Numerical results show that the maximum pressure gradient of the propagating compression wave decreases with increase of the wave length of the unsteady expansion wave. It is found that the impulsive noise reduction can be obtained when the unsteady expansion wave with a large wave length is emitted just before the train enters the tunnel. The present results give the possibility to reduce the impulsive noise at the exit of tunnel.

연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석 (Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building)

  • 김성실;김영일
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

전술환경에서 QoS 보장을 위한 클래스 기반 FQ-Codel 알고리즘 적용 연구 (Application Study of FQ-CoDel Algorithm based on QoS-guaranteed Class in Tactical Network)

  • 박주만
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.53-58
    • /
    • 2019
  • 본 논문은 전술 통신망에서 QoS 향상을 위한 클래스 기반의 FQ-CoDel(Flow queue-Control Delay) 알고리즘을 제안한다. 전술 통신망에서 다양한 응용체계 서비스를 제공하게 되면서 병목현상으로 인한 트래픽 손실 및 지연 문제가 대두되었고 따라서 효과적인 트래픽 처리 방안 연구에 대한 필요성이 제기되었다. 제안방안은 클래스 기반의 FQ-CoDel 알고리즘을 이용한 동적인 버퍼 관리 및 스케줄링 기술로써 서비스 특성 및 중요도에 따라 해당 큐에 패킷을 분류하고 주기적으로 각 패킷의 대기시간을 체크하여 기준 대기 시간을 초과하는 경우 해당 패킷을 폐기하여 큐에 저장된 트래픽 양을 일정 수준으로 조절한다.

가압중수형 원자로의 중성자 감속재 순환 유동가시화와 삼차원 전산해석 (Visualization and 3D Numerical Analysis of the Circulation Flow of the Neutron Moderator in a Heavy-Water Nuclear Reactor)

  • 엄태광;이재영
    • 대한기계학회논문집B
    • /
    • 제36권2호
    • /
    • pp.189-196
    • /
    • 2012
  • 현 운행중인 중수로의 안전장치인 감속재는 원전사고시 최종 열침원의 역할을 감당한다. 감속재 연구 수행을 위해 CANDU6 의 축소화 모델인 HUKINS 는 최대출력 10kW 로, 칼란드리아 직경은 원모델의 1/8 에 해당하는 0.95m 이며 축방향 길이가 38.4mm 의 열원 88 개가 삽입되어 있다. HUKINS 내 감속재 유동패턴의 발생 여부를 판단하고자 화학처리기법을 활용하였고 그 결과 출력파워 약 7.7kW 에서 각입력유량을 4,7,11L/min 으로 유입시 감속재의 유동패턴이 부력기조유동, 혼합양상유동, 모멘텀 기조유동의 양상을 나타났다. 3 가지 유동패턴에 대해 육면체 격자를 기본으로 구성된 약 190 만개의 격자수 내에서 난류모델 $k{\varepsilon}$의 예측결과와 실험결과간에 유사성을 보임으로써 HUKINS 가 CANDU6 감속재 유동의 실험적 연구에 사용 가능함을 입증했다.