• Title/Summary/Keyword: Total Available Energy

Search Result 228, Processing Time 0.024 seconds

Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond (소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究))

  • Pak, Ee-Tong;Seo, Ji-Weon
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

Evaluation of reactor pulse experiments

  • I. Svajger;D. Calic;A. Pungercic;A. Trkov;L. Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1165-1203
    • /
    • 2024
  • In the paper we validate theoretical models of the pulse against experimental data from the Jozef Stefan Institute TRIGA Mark II research reactor. Data from all pulse experiments since 1991 have been collected, analysed and are publicly available. This paper summarizes the validation study, which is focused on the comparison between experimental values, theoretical predictions (Fuchs-Hansen and Nordheim-Fuchs models) and calculation using computational program Improved Pulse Model. The results show that the theoretical models predicts higher maximum power but lower total released energy, full width at half maximum and the time when the maximum power is reached is shorter, compared to Improved Pulse Model. We evaluate the uncertainties in pulse physical parameters (maximum power, total released energy and full width at half maximum) due to uncertainties in reactor physical parameters (inserted reactivity, delayed neutron fraction, prompt neutron lifetime and effective temperature reactivity coefficient of fuel). It is found that taking into account overestimated correlation of reactor physical parameters does not significantly affect the estimated uncertainties of pulse physical parameters. The relative uncertainties of pulse physical parameters decrease with increasing inserted reactivity. If all reactor physical parameters feature an uncorrelated uncertainty of 10 % the estimated total uncertainty in peak pulse power at 3 $ inserted reactivity is 59 %, where significant contributions come from uncertainties in prompt neutron lifetime and effective temperature reactivity coefficient of fuel. In addition we analyse contribution of two physical mechanisms (Doppler broadening of resonances and neutron spectrum shift) that contribute to the temperature reactivity coefficient of fuel. The Doppler effect contributes around 30 %-15 % while the rest is due to the thermal spectrum hardening for a temperature range between 300 K and 800 K.

UPTAKE OF COBALT BY GOLDFISH(Carassius auratus) (금붕어(Carassius auratus)에 의한 코발트 흡수)

  • Kim, Jin-Kyu;Lee, Jeong-Ho
    • Journal of fish pathology
    • /
    • v.1 no.2
    • /
    • pp.131-134
    • /
    • 1988
  • Radiocobalt was used as tracer to study the uptake of cobalt by fish either from water or food source, respectively. Four groups of goldfish were exposed to $^{57}Co$-labelled water under 4 different temperatures, while another four groups were fed labelled feed pellets at $15^{\circ}C$. Results indicate that water temperature has no significant effect on the uptake of cobalt from water. The uptake from water is quite a slow process since the cobalt uptaken from water reached 0.0006% of available activity at best on the 13th day of exposure. The uptake from a labelled feed source showed a linear increase with time over the period of ninety days. On the 90th day of experiment the percentage of available activity consumed seemed to be approaching an equilibrium point at roughly 12% of the total activity fed to the goldfish.

  • PDF

Simulation of Characteristics of Lens and Light Pipe for High Concentration Solar PV System (고집광 태양광 발전을 위한 렌즈 및 광 파이프 특성 시뮬레이션)

  • Ryu, Kwnag-Sun;Shin, Goo-Hwan;Cha, Won-Ho;Myung, Noh-Hoon;Kim, Young-Sik;Chung, Ho-Yoon;Kim, Dong-Kyun;Kang, Gi-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.282-286
    • /
    • 2011
  • The artificial increase in the solar intensity incident on solar cells using lenses or mirrors can allow solar cells to generate equivalent power with a lower cost. In application areas of Fresnel lenses as solar concentrators, several variations of design were devised and tested. Some PV systems still use commercially available flat Fresnel lenses as concentrators. In this study, we designed and optimized flat Fresnel lens and the 'light pipe' to develop 500X concentrated solar PV system. We performed rigorous ray tracing simulation of the flat Fresnel lens and light-pipe. The light-pipe can play imporatant roles of redistributing solar energy at the solar cell and increase the mechanical tolerance so that it can increase the lifetime of the high-concentration solar PV system and decrease the cost of manufacturing. To investigate the sensitivity of the solar power generated by the concentrated solar PV according to the performance of lens and light pipe, we performed raytracing and executed a simulation of electrical performance of the solar cell when it is exposed to the non-uniform illumination. We could conclude that we can generate 95 % or more energy compared with the energy that can be generated by perfectly uniform illumination once the total energy is given the same.

  • PDF

An Analysis of Idling Stop Time Using Real On-road Driving Data (실도로 주행 데이터를 이용한 공회전 정지 시간의 분석)

  • Hong, Seong-Tae;Lee, Beom-Ho;Lee, Dae-Yeop;Sim, Mu-Gyeong;Im, Jae-Myeong
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.1
    • /
    • pp.25-38
    • /
    • 2010
  • In this study, the real on-road driving data were analyzed to draw the various characteristics related to idling of vehicles. The results revealed that the average idling time of a city bus corresponds to 30.9% of the total daily driving time. Among this, for about 21.6% of the total daily driving time, it is available that an engine can be halted while the vehicle stops. It is a daytime when the portion of time, for which idling stop is available, is peak. Due to idling stop, an increase of turnaround was not found throughout this analysis. When a city bus stops at a traffic right, idling periods were long enough to execute the idling stop, during which an engine halts. Whereas, during the idling time for bus stops, the idling periods were not so long enough to execute idling stop. Deceleration periods among the total turnarounds of a city bus occupies about 24.7%, during which, for about 30%, a deceleration maintains for more than four seconds. Thus, using the energy during deceleration period, which then can be recovered from braking energy, it was also found that a hybrid system can be effectively implemented to a city bus.

Three-dimensional FE analysis of headed stud anchors exposed to fire

  • Ozbolt, Josko;Koxar, Ivica;Eligehausen, Rolf;Periskic, Goran
    • Computers and Concrete
    • /
    • v.2 no.4
    • /
    • pp.249-266
    • /
    • 2005
  • In the present paper a transient three-dimensional thermo-mechanical model for concrete is presented. For given boundary conditions, temperature distribution is calculated by employing a three-dimensional transient thermal finite element analysis. Thermal properties of concrete are assumed to be constant and independent of the stress-strain distribution. In the thermo-mechanical model for concrete the total strain tensor is decomposed into pure mechanical strain, free thermal strain and load induced thermal strain. The mechanical strain is calculated by using temperature dependent microplane model for concrete (O$\check{z}$bolt, et al. 2001). The dependency of the macroscopic concrete properties (Young's modulus, tensile and compressive strengths and fracture energy) on temperature is based on the available experimental database. The stress independent free thermal strain is calculated according to the proposal of Nielsen, et al. (2001). The load induced thermal strain is obtained by employing the biparabolic model, which was recently proposed by Nielsen, et al. (2004). It is assumed that the total load induced thermal strain is irrecoverable, i.e., creep component is neglected. The model is implemented into a three-dimensional FE code. The performance of headed stud anchors exposed to fire was studied. Three-dimensional transient thermal FE analysis was carried out for three embedment depths and for four thermal loading histories. The results of the analysis show that the resistance of anchors can be significantly reduced if they are exposed to fire. The largest reduction of the load capacity was obtained for anchors with relatively small embedment depths. The numerical results agree well with the available experimental evidence.

A Study of Ultrasonic concentrator with Rotating parablic surace (회전 기물면을 이용한 초음파 집속기에 관한 연구)

  • 김주홍;전병실
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1974
  • This paper discribes the reflector type ultrasonic concentrator which makes hghintencity of ultrasonic field. This was made by rotating parabolic surface which only using total reflection aria, that makes boundary by the critical angle of reflection of sound. I made two binds of concentrator acording to the type of ultrasonic transduser: one is internal surface reflector type concentrator, which is available for disc type transducer, and the other is external surface reflector type concentrator which is available cylinderical transduser. In the mony aspects the reflector tripe concentrator is supel'ier to the reflection type concentrator as plastics lens; It is more durable in high temperature and high intencity ultrasonicfield then refrector type concentrator because of it is made by glass or metal, and it has higher. efficiency because of it wasts made by only total reflection aria that is without absoption lose. I think this is useful ultrasonic concentrator in mony industrial field, in which high intencitr of ultrasonic energy was used.

  • PDF

Fuzzy Algorithms to Generate Level Controllers for Nuclear Power Plant Steam Generators (원전 증기 발생기 수위제어용 퍼지 알고리즘)

  • Moon, Byung-Soo;Park, Jae-Chang;Kim, Dong-Hwa;Kim, Byung-Koo
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.222-232
    • /
    • 1993
  • In this paper, we present two sets of fuzzy algorithms for the steam generator level control ; one for the high power operations where the flow error is available and the other for the low power operations where the flow error is not available. These are converted to a PID type controller for the high power case and to a quadratic function form of a controller for the low power case. These controllers are implemented on the Compact Nuclear Simulator at Korea Atomic Energy Research Institute and tested by a set of four simulation experiments for each. For both cases, the results show that the total variation of the level error and of the flow error are about 50% of those by the PI controllers with about one half of the control action. For the high power case, this is mainly due to the fact that a combination of two PD type controllers in the velocity algorithm form rather than a combination of two PI type controllers in the position algorithm form is used. For the low power case, the controller is essentially a PID type with a very small integral component where the average values for the derivative component input and for the controller output are used.

  • PDF

A Gas-Phase Investigation of Oxygen-Hydrogen Exchange Reaction of O(3P) + C2H5 → H(2S) + C2H4O

  • Jang, Su-Chan;Park, Min-Jin;Choi, Jong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.839-844
    • /
    • 2014
  • The gas-phase radical-radical reaction $O(^3P)$ + $C_2H_5$ (ethyl) ${\rightarrow}$ $H(^2S)$ + $CH_3CHO$(acetaldehyde) was investigated by applying a combination of vacuum-ultraviolet laser-induced fluorescence spectroscopy in a crossed beam configuration and ab initio calculations. The two radical reactants $O(^3P)$ and $C_2H_5$ were respectively produced by photolysis of $NO_2$ and supersonic flash pyrolysis of the synthesized precursor azoethane. Doppler profile analysis of the nascent H-atom products in the Lyman-${\alpha}$ region revealed that the average translational energy of the products and the average fraction of the total available energy released as translational energy were $5.01{\pm}0.72kcalmol^{-1}$ and 6.1%, respectively. The empirical data combined with CBS-QB3 level ab initio theory and statistical calculations demonstrated that the title exchange reaction is a major channel and proceeds via an addition-elimination mechanism through the formation of a short-lived, dynamical addition complex on the doublet potential energy surface. On the basis of systematic comparison with several exchange reactions of hydrocarbon radicals, the observed small kinetic energy release can be explained in terms of the loose transition state with a product-like geometry and a small reverse activation barrier along the reaction coordinate.

Chemical Changes in Garlic Bulbs Resulting from Ionizing Energy Treatment at Sprout-Inhibition Dose (발아억제 선량의 전리에너지가 마늘의 성분변화에 미치는 영향)

  • Kwon, Joong-Ho;Yoon, Hyung-Sik;Byun, Myung-Woo;Cho, Han-Ok
    • Applied Biological Chemistry
    • /
    • v.31 no.2
    • /
    • pp.147-153
    • /
    • 1988
  • An assessment of the nutritional aspects on irradiated garlic bulbs, stored for 10 months at low$(3{\pm}1^{\circ}C,\;75{\sim}85%\;R.H.)$ and room$(12{\pm}5^{\circ}C,\;75{\sim}85%\;R.H.)$, was performed by means of investigations on the changes in some chemical composition. Ionizing energy treatment at 0.1kGy gamma-ray brought about no significant changes in the moisture content of stored garlic, but it contributed to the reduction of the changes in total available carbohydrate content of stored garlic. After 8 months of storage, the content of free sugars was significantly higher in nonirradiated garlic than in irradiated garlic, especially in low temperature storage. The 0.1kGy irradiation at the sprout-inhibition dose had no apparent effect on the content of ascorbic acid in stored garlic, and sulfurcontaining amino acids appeared to be little affected by the irradiation at 0.1kGy, even though there were some sensitive amino acids like glutamic and aspartic acids.

  • PDF