• Title/Summary/Keyword: Torsional strength

Search Result 299, Processing Time 0.025 seconds

Manufacturing of High-Strength and High-Ductility Pearlitic Steel Wires Using Noncircular Drawing Sequence (비원형 신선을 이용한 고강도-고연성 펄라이트 강선의 제조)

  • Baek, Hyun Moo;Hwang, Sun Kwang;Joo, Ho Seon;Im, Yong-Taek;Son, Il-Heon;Bae, Chul Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.743-749
    • /
    • 2014
  • In this study, a noncircular drawing (NCD) sequence for manufacturing high-strength and high-ductility pearlitic steel wires was investigated. Multipass NCD was conducted up to the 12th pass at room temperature with two processing routes (defined as the NCDA and NCDB), and compared with the wire drawing (WD). During the torsion test, delamination fracture in the drawn wire was observed in the 10th pass of the WD whereas it was not observed until the 12th pass of the NCDB. From X-ray diffraction, the circular texture component that increases the likelihood of delamination fracture of the drawn wire was rarely observed in the NCDB. Thus, the improved ability of the multipass NCDB to manufacture high-strength pearlitic steel wires with high torsional ductility compared to the WD (by reducing the likelihood of delamination fracture) was demonstrated.

A Simplified Approach to the Analysis of the Ultimate Compressive Strength of Welded Stiffened Plates (용접된 보강판의 압축 최종 강도의 간이 해석법)

  • C.D. Jang;Seung-Il Seo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.141-154
    • /
    • 1993
  • In this paper, a method to calculate the ultimate compressive strength of welded one-sided stiffened plates simply supported along all edges is proposed. At first initial imperfections such as distortions and residual stresses due to welding are predicted by using simplified methods. Then, the collapse modes of the stiffened plate are assumed and collapse loads for each mode are calculated. Among these loads, the lowest value is selected as the ultimate strength of the plate. Collapse modes are assumed as follows ; (1) Overall buckling of the stiffened plate$\rightarrow$Overall collapse due to stiffener bending (2) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener yielding (3) Local buckling of the plate part$\rightarrow$Overall collapse due to stiffener berthing (4) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener tripping. The elastic large deflection analysis based on the Rayleigh-Ritz method is carried out, and plastic analysis assuming hinge lines is also carried out. Collapse load is defined as the cross point of the two analysis curves. This method enables the utimate strength to be calculated with small computing time and a good accuracy. Using the present method, characteristics of the stiffener including torsional rigidity, bending and tripping can also be clarified.

  • PDF

A Investigation on Inelastic Lateral-Torsional Buckling Strength of I-Beam with Load Height Effects (하중고 효과가 비탄성 I형보의 횡-비틀림 좌굴거동에 미치는 영향 고찰)

  • Park, Yi Seul;Yoo, Sang Ryang;Oh, Jeong Jae;Park, Jong Sup
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.155-155
    • /
    • 2011
  • 일반적으로 I형 보에 횡하중이 작용하는 경우, 횡 변위와 함께 회전을 동반하는 횡-비틀림 좌굴(Lateral-Torsional Buckling)이 발생하게 된다. 이러한 I형 보의 탄성 및 비탄성 횡-비틀림 좌굴에 대한 해석적 이론적 연구는 이미 많은 연구자들에 의해 수행되었다(Timoshenko 등, 1961; Galambos, 1963; Lindner, 1974; Trahair, 1993). I형 보의 비지지 길이 내 하중이 작용할 때 모멘트 구배계수(Cb)는 하중이 부재 단면에 작용하는 위치에 따라 달라지게 되는데 이를 하중고 효과(Load Height Effects)라고 한다. 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수 제안식은 Nethercot & Rockey(1971)에 의해 연구된 바 있다. 또한 Helwig 등(1997)은 Nethercot & Rockey(1971)의 제안식을 간략화 하여 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수식을 제안하였다. 그러나 현재까지 진행 된 하중고 효과에 대한 연구는 탄성 영역 내 비지지 길이가 존재하는 I형 보에 대한 제안식이며 현재까지 비탄성 영역 내 비지지 길이를 갖는 I형 보의 하중고 효과에 대한 연구는 진행된 바 없다. 본 연구는 비탄성 영역 내 비지지 길이가 존재하는 I형 보의 하중고 효과를 고려한 비탄성 횡-비틀림 좌굴강도에 대한 연구를 수행하였다. 하중조건으로는 집중하중 과 등분포 하중을 적용시켰으며, 비선형 횡-비틀림 좌굴 해석을 위해 잔류응력 및 초기변형을 고려하였다. Pi와 Trahair(1995)이 고려한 단순직선분포를 잔류응력으로 가정하였으며, 국내 I형강 표준 치수 허용치(현대제철, 2006)에 근거하여 부재 길이의 0.1%를 초기 최대 횡 변위로 적용하여 초기제작오차로 고려하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)와 Helwig 등(1997)의 연구내용을 바탕으로 범용구조해석 프로그램(ABAQUS, 2007)을 이용하여 비탄성 영역 내 존재하는 I형보의 횡-비틀림 좌굴강도를 산정하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)및 Helwig 등(1997)의 모멘트구배계수 제안식과 비교 분석 하였고 회기분석프로그램 MINITAB(2006)을 이용하여 비탄성 영역 내 비지지길이가 존재하는 I형보의 하중고 효과를 고려한 모멘트구배계수식을 개발 제안하였다. 본 연구에서 개발된 제안식은 경제적이고 합리적인 휨부재 강도평가에 적극 활용될 수 있으며, 비탄성 영역내 I형보의 횡-비틀림 좌굴강도 및 휨강도 연구에 널리 활용될 것이다.

  • PDF

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates (HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.407-418
    • /
    • 2014
  • As a continuing work of previously conducted standard tension tests, full-scale flexural tests were conducted in this study to assess the structural performance the CJP groove welded joints connecting thick HSA800 plates. Two welding electrodes were available at the time of this experimental research; one was GMAW-based electrode A and the other FCAW-based electrode B. Three full-scale box-type beam specimens with single bevel- and V-groove CJP welded joints were fabricated from 60mm and 25mm thick HSA800 plates according to the AWS-prequalified groove welded joint details. In designing the specimens, all possible limit states like local and lateral torsional buckling were carefully controlled in order to induce flexural plastic yielding or eventual joint fracture. All the CJP joints made by both welding electrodes showed satisfactory performance and were able to transfer the tensile flange forces higher than that corresponding to the measured tensile strength of HSA800 flange plates. However, it should be noted that, during fabrication, serious concerns about the welding efficiency and workability of the GMAW-based electrode were raised by a certified welder. The fracture occurred at the unbeveled (or vertical) interface between the weldment and the base metal when the GMAW-based electrode was used in the single-bevel joint, implying the possibility of insufficient melting. Thus, the FCAW-based electrode B is again recommended as the choice of welding electrode for HSA800 plates. The limited test data of this study implies that the V-groove CJP joint should be used in favor of the single bevel CJP joint, if possible.

An Evaluation on the Shear Strength of New Type Shear Connectors for a Simple Steel-Concrete Composite Deck (초간편 강합성 바닥판 신형식 전단연결재의 전단내력 평가)

  • Yoon, Ki Yong;Kim, Sang Seup;Han, Deuk Cheon
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.519-528
    • /
    • 2008
  • A simple steel-concrete composite deck is developed for preventing the lateral torsional buckling of girders that are under construction and for reducing the term of works using H-shaped rolled beams as bridge girders. A new type of shear connectors is also developed for the composite behavior between a simple steel-concrete composite deck and the rolled beams by the connecting conditions between the deck and the girders. One is a connector bolt that is lengthened and split or tightened with two nuts and the other is an I-shaped rolled beam welded on a steel plate with a number of holes punched through the web. In this study, to estimate the shear strength of those shear connectors the push-out tests are performed and the test results are compared with that of the previous studies and the codes. The result of the push-out tests of the connector bolts showed that the shear performance is similar to that of the stud connector and revealed that the equation for the shear strength in the Korean Specification of Highway Bridge overestimates the shear capacity of the connector bolt whose diameter is larger than 19mm. From the push-out tests of punched I-shaped rolled beams with varying welding amounts, with the small amount of welding, shear capacity is governed by the shear capacity of welding. On the other hand, shear capacity is governed by the size of the punched I-shaped rolled beams, regardless of the amount of welding.

Undisturbed Sampler for Characterizing the Behaviour of Weathered Granite Residual Soils (화강풍화토의 거동 특성 규명을 위한 비교란 시료채취기 개발)

  • 정순용;이승래
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.13-24
    • /
    • 1997
  • In Korea, granite is abundant and occupies around two-thirds of the country's ground. Bven though weathered granite residual soils are widely distributed, undisturbed sampling of this soil is extremely difficult because of the particultate structure. This difficulty has kept away the researchers from investigating !he deformational characteristics of weathered granite residual soil. Thus, a special undisturbed sampling device was developed and undisturbed samples were prepared for triaxial compression (TX), resonant column(RC), and torsional shear (75) tests. Local deformation transducer (LDT) was fabricated for internal strain measurements during TX tests. Both undisturbed samples and statically compacted samples of same density were tested by using TX with LDT, RC, and 75 test equipments. The behaviour of statically compacted specimens was almost the same as that of undisturbed samples in the strain ranges below 1 percent. The stiffness and strength decreased with increasing degree of weathering. In case of undisturbed specimens, strains at failure are widely varied from 2 percent to 11 percent, and planes of failure are irrelevant to the angle of internal friction due to the inhomogeneous nature.

  • PDF

Effects of Number of bays and Bracing Member on the Ultimate Behavior of System Scaffolds (Bay 수와 가새재 설치가 시스템 비계 극한거동에 미치는 영향)

  • Lee, Sun-Woo;Jang, Nam-Kwon;Won, Jeong-Hun;Jeong, Seong-choon
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.6-15
    • /
    • 2020
  • This study examined the structural behaviors and ultimate loads of assembled system scaffolds by load tests. Considering the number of bay and bracing installation, four specimens were tested. The bays were divided into 1 bay and 2 bays, with and without the bracing member installed. Failure modes and horizontal displacements show that the whole column buckled without showing no point of inflection in the column, regardless of whether or not braces were installed. Thus, the current design method of selecting the vertical spacing between the horizontal members of the system scaffold as the effective buckling length underestimates the effective buckling length. In case of 1 bay specimens, the ultimate loads between specimens with and with bracing members are similar. However, in case of 2 bay specimens, the specimen with bracing members shows the increased ultimate load of 36% compared with that without bracing members. In addition, as the number of bays in the system scaffold increases, the ultimate load of the unit vertical column increases in case of the specimen with bracing installation. However, in the specimen without bracing members, the ultimate load of the unit column reduces with the increment of the number of bays due to the torsional buckling. Therefore, it is essential to install bracing members to increase the whole strength of system scaffolds and the ultimate load of the unit column.

Influence of Lateral Bracing on Lateral Buckling of Short I-Beams Under Repeated Loadings (반복하중을 받는 짧은 I형 보의 횡좌굴에 대한 횡브레이싱의 영향에 관한 고찰)

  • 이상갑
    • Computational Structural Engineering
    • /
    • v.5 no.1
    • /
    • pp.109-118
    • /
    • 1992
  • Lateral bracing has long been used in design practice to enhance the carrying capacity of the lateral buckling of the beam. Many factors, critically important to lateral bracing performance, do not appear in design formulas. Some of these factors are discussed in this study for the application to short I - beams under repeated loadings through parametric studies with an analytical model : the brace location along the length of the beam, the height of the bracing above the shear center of the beam, and the strength and stiffness of the brace. The parametric studies are carried out using a propped cantilever arrangement, and also using a geometrically (fully) nonlinear beam model for the brace as well as the beam to capture the system buckling. An idealized bracing system is configured to restrain lateral motion, but not rotation. A multiaxial cyclic plasticity model is also implemented to better represent cyclic metal plasticity in conjunction with a consistent return mapping algorithm.

  • PDF

Dynamic Response of Unreinforced Masonry Building (비보강 조적조의 동적 거동)

  • Kim, Nam-Hee;Kim, Jae-Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.1-14
    • /
    • 2004
  • The seismic behavior of a 1/3-scale model of a two-story unreinforced masonry (URM) structure typically used in constructing low-rise residential buildings in Korea is studied through a shaking table test. The purposes of this study are to investigate seismic behavior and damage patterns of the URM structure that was not engineered against seismic loading and to provide its experimental test results. The test structure was symmetric about the transverse axis but asymmetric to some degrees about longitudinal axis and had a relatively strong diaphragm of concrete slab. The test structure was subjected to a series of differentlevels of earthquake shakings that were applied along the longitudinal direction. The measured dynamic response of the test structure was analyzed in terms of various global parameters (i.e., floor accelerations, base shear, floor displacements and storydrift, and torsional displacements) and correlated with the input table motion. Moreover, different levels of seismic performance were suggested for performance-based design approach. The results of the shaking table test revealed that the shear failure was dominant on a weak side of the 1stfloor while the upper part of the test model remained as a rigid body. Also, it was found that substantial strength and deformation capacity existed after cracking.