• Title/Summary/Keyword: Torque test

Search Result 1,080, Processing Time 0.04 seconds

Principle of Design and Performance of the Torque Sensor for a Electrical Power Steering (전동식 파워스티어링(EPS)용 토크센서의 설계원리와 성능테스트)

  • Lee Eung-Shin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.121-126
    • /
    • 2005
  • This paper describes the attributes, performance and development status of a high performance capacitive torque sensor intended for use in a electric power steering (EPS) system. The EPS system is composed of torque sensor, ECU, motor, gears and etc. Among the elements, torque sensor in the steering column is one of the core technologies. The new capacitive torque sensor in this paper is developed differently from working principle and mechanical structure compare to extant torque sensors in market and patent. Based on the result of numerical analysis, a experimental equipment is made which is composed of a test jig and a capacitive sensor and validity of numerical analysis and feasibility of the torque sensor are verified.

A Study on the Torque Control Method of a Hydraulic Actuation System for Measuring the Dynamic Stiffness of Missile Fin Actuators (유도무기용 날개구동기의 동적 강성 측정을 위한 유압 구동장치의 토크제어 기법에 관한 연구)

  • Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • This paper presents a torque control method of a hydraulic actuation system for measuring the dynamic stiffness of missile fin actuators. We propose a new control technique called Dual Dynamic Torque Feedback Control(DDTFC), which improves the stability of the torque control system and enables fast tracking of torque command. The developed control scheme is derived from the physical understanding based on mathematical modelling and analysis. The dynamics of hydraulic torque control servo-system is unravelled via physics-based modelling and nonparametric system identification. In order to verify the effectiveness of the method, the experiment is carried out with a test equipment for measuring the dynamic stiffness. The experiment and simulation results show that DDTFC gives stability improvement.

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

Design of Two-axis Force/Torque Sensor for Hip Joint Rehabilitation Robot (고관절 재활로봇의 2축 힘/토크센서 설계)

  • Kim, Han-Sol;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.7
    • /
    • pp.524-529
    • /
    • 2016
  • We describe the design and fabrication of a two-axis force/torque sensor with parallel-plate beams (PPBs) and single beams for measuring force and torque in hip-joint rehabilitation exercise using a lower rehabilitation robot. The two-axis force/torque sensor is composed of an Fz force sensor and a Tz torque sensor, which detect z direction force and z direction torque, respectively. The two-axis force/torque sensor was designed using the FEM (Finite Element Method) and manufactured using strain gages. The characteristics experiment of the two-axis force/torque sensor was carried out. The test results show that the interference error of the two-axis force/torque sensor was less than 0.64% and the repeatability error and the non-linearity of the two-axis force/torque sensor were less than 0.03%. It is thought that the developed two-axis force/torque sensor could be used for a lower rehabilitation robot.

Direct Torque Control of Synchronous Reluctance Motor Using the AC standstill Test (교류 정지시험법을 이용한 동기형 릴럭턴스 전동기의 직접토크제어 특성 연구)

  • Yun, Jun-Bo;Kim, Sol;Lim, Jin-Jae;Lee, Moon-Ju;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.56-58
    • /
    • 2003
  • The Synchronous inductance in Synchronous Reluctance Motor is an element that is proportional to torque. the exact value must be found for controlling and the performance development of motors. In this paper, the inductances that are obtained by the Finite Element Method and AC standstill Test are compared each other. When controlling the direct torque. the fast response characteristics has been carried out with the inductace by the AC stanstill Test. To test the proposal controller, A Synchronous Reluctance Motor has been designed and manufactured and the adequacy of the proposal control are confirmed thought simulations and experiments.

  • PDF

Method of Decreasing the Deviation of Corrected Engine Torque using Knock Correction Rate in Gasoline Engine Performance Test on Dynamometer (가솔린엔진 대상 성능시험시의 노킹보정률을 사용한 엔진 수정토크의 편차개선)

  • Cho, Yoon-Ho;Kim, Woo-Tai;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • Recent trends of development in small size gasoline engines are both to have higher compression ratio for the purpose of improved fuel consumption and to advance spark timing up to DBL in a low to mid engine speed region for a good acceleration performance of vehicles. However, there occurs the deviation of corrected engine torque results during engine performance test on dynamometer because test conditions influence the onset of knock. Therefore, this research shows the test deviation of corrected engine torque decreases when knock correction rate is used.

Study of a Durability Test for Single-input Multi-output Power Take-off Gearboxes (단일입력 다출력 PTO 기어박스의 내구성시험에 관한 연구)

  • Lee, Yong Bum;Yoo, Han Ju
    • Journal of Drive and Control
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This study analyzed a life test method for a power take-off (PTO) gearbox. An engine transfers mechanical power (rotation and torque) to a hydraulic pump through a PTO Gearbox with one input shaft and three output shafts. PTO gear box durability under high loads over long time periods was tested using dynamometers. In order to reflect the rated operating conditions, power must be distributed to each output shaft, and experiments were conducted under various conditions to verify the characteristics of the distributed power. An accelerated life test was designed using speed and torque as acceleration factors. Also, efficiency tests were conducted under various load conditions. Also, a lubrication oil composition analysis was performed to analyze gearbox wear status.

A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery (고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구)

  • Lee, Yong-Bok;Kim, Tae-Ho;Kim, Chang-Ho;Lee, Nam-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.199-206
    • /
    • 2002
  • This paper describes a reliability characteristics of an air foil journal bearing for high speed turbomachinery at room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with motor driven test rig. Lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About load carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, The trends in change of start torque, stop torque, and bearing temperature were shown during 10,000 cycle start-stop test of an air foil journal bearing. from the results of this work, an air foil bearing will be done well, as a supported bearing for high speed turbo-compressor.

  • PDF

A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery (고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구)

  • Kim, Tae-Ho;Lee, Yong-Bok;Kim, Chang-Ho;Lee, Nam-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.7-14
    • /
    • 2003
  • This paper describes reliability characteristics of an air foil journal bearing for high-speed turbomachinery at a room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with a motor-driven test rig. A lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About a load-carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, the trends in change of start torque, stop torque, and bearing temperature were shown during a 10,000-cycle start-stop test of an air foil journal bearing. We found that an air foil bearing performs well, as a supported bearing for the high-speed turbocompressor.