• Title/Summary/Keyword: Torque Analysis

Search Result 2,238, Processing Time 0.036 seconds

A Novel Cogging Torque Reduction Method for Single-Phase Brushless DC Motor

  • Park, Young-Un;Cho, Ju-Hee;Rhyu, Se-Hyun;Kim, Dae-Kyong
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.117-124
    • /
    • 2013
  • Single-phase, brushless DC (BLDC) motors have unequal air-gaps to eliminate the dead-point where the developed torque is zero. Unfortunately, these unequal air-gaps can deteriorate the motor characteristics in the cogging torque. This paper proposes a novel design for a single-phase BLDC motor with an asymmetric notch to solve this problem. In the design method, the asymmetric notches were placed on the stator pole face, which affects the change in permanent magnet shape or the residual flux density of the permanent magnet. Parametric analysis was performed to determine the optimal size and position of the asymmetric notch to reduce the cogging torque. Finite element analysis (FEA) was used to calculate the cogging torque. A more than 28% lower cogging torque compared to the initial model with no notch was achieved.

Analysis of the Acoustic Noise Characteristics by Controlling Lead Angle in Brushless DC Motors (진상각 제어에 따른 BLDC 전동기의 소음 특성 해석)

  • 황상문;김경태;정승규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.101-109
    • /
    • 2000
  • Mutual torque ripple in a brushless DC motor is the main source of acoustic noise, especially fur motor operation with high speed and torque. This paper presents a method to obtain mutual torque ripple to identify acoustic noise source. Mutual torque ripple can be determined by analyzing phase current shape and magnetic circuit with different lead angles. Current shape is determined by state space model of voltage equation with the use of inductance calculated by FEM, and confirmed by experimental results. Mutual torque ripple is also determined by FEM analysis for the calculated current shape. Acoustic noise experiment reveals that mutual torque ripple with different lead angle is one of the main sources for noise generation in a brushless DC motor.

  • PDF

Modeling and Detent Torque Hormonic Analysis of Hybrid Type Step Motor (하이브리드형 스텝모터의 모델링 및 디텐트 토크 고조파 분석)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.14-21
    • /
    • 2002
  • This paper did the study target for modeling, characteristics analysis and harmonic reduce with the detent torque of a 4 phase and 5 phase hybrid type step motor. For this, it was attempted to derive the mathematical modeling and used the permeance method for flux field analysis. Through this analysis result, this paper acquired the detent torque of this model. To compare the characteristics analysis of phase difference with two motors structure it have obtained to derive the operating detent torque with this model. Here, 5 phase motor has known the harmonic reduce of detail torque compare with 4 phase motor. Also, that has showed to improved the step response. The analysis result has represent the effect that a fundamental component of the permeance distribution produces the average torque and that harmonic components produce the ripple torque.

Structure Analysis and Loading Test of Torque arm for Driving Gear Unit of Unique Model (독자모델 감속구동장치 토크암의 구조해석 및 하중시험에 관한 연구)

  • Cha Soo-Deok;Choi Jin-Wook;Yu Jai-Il;Lee Min-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.211-215
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of torque arm for driving gear unit. The purpose of the analysis and test is to evaluate an safety which torque arm shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Driving gear unit consist of gearbox and torque arm. Both components, torque arm is significant component subjected to the vehicle and motor loads. The evaluation methode is used the FEM analysis, static and fatigue test. The test results have been very safety and stable for design load conditions.

  • PDF

A Study on the Performance Analysis of Butterfly Valve in Water Fire Extinguishing System (수계소화시스템 버터플라이 밸브의 성능해석에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2007
  • Performance analysis of the butterfly valve in water fire extinguishing has been carried out. Performance analysis of the butterfly valve are investigated for torque characteristics, pressure loss and cavitations. The torque characteristics of disc are corrected for the angles of attack of valve disc by theoretical torque equation, and correction equation is added. The pressure loss coefficient on opening angle of valve has been formulated by applying the Carnot's equations. The torque characteristics, pressure loss and cavitations of the butterfly valve are analyzed for the ratio of disc thickness to the valve diameter. Cavitations are analyzed from the pressure loss coefficient of valve. The analysis of pressure loss and cavitation has been carried out change of the thickness ratio on opening angle of valve. These analysis data are utilize to necessary engineering data to develope of the butterfly valve.

Design and Torque Ripple Analysis of Brush-less DC Motor According to Delta Winding Connection

  • Lee, Tae-Yong;Seo, Myung-Ki;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.166-175
    • /
    • 2015
  • In this study, we describe the design method of a Brush-less DC (BLDC) motor with delta winding connection. After designing delta winding connection model with the $60^{\circ}$ flat-top region of the Back Electro-Motive Force (BEMF), an ideal current source analysis and a voltage source analysis, with a 6-step control, were conducted primarily employing Finite Element Method. In addition, as a current controller, we considered the Current Regulator with PI controller using Simulink for the comparison of torque characteristics. When the input current is controlled, the switching regions and reference signals are determined by means of the phase BEMF zero-crossing point. In reality, the input current variation depends on the inductance as well as input voltage, and it causes a torque ripple after all. Therefore, each control method considered in this research showed different torque ripple results. Based on the comparison, the causes of the torque ripple have been verified in detail.

Automated FEA Simulation of Micro Motor (마이크로 모터의 자동화된 FEA 시뮬레이션)

  • Lee Joon-Seong
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.3
    • /
    • pp.13-22
    • /
    • 2002
  • This paper describes an automated evaluation of electrostatic field for micro motors whose sizes range 10 to 103um. Electric field modeling in micro motors has been generally restricted to in-plane two-dimensional finite element analysis (FEA). In this paper, the actual three-dimensional geometry of the micro motor is considered. An automatic FE mesh generation technique, which is based on the fuzzy knowledge processing and computational geometry techniques, is incorporated in the system, together with one of commercial FE analysis codes and one of commercial solid modelers. The system allows a geometry model of concern to be automatically converted to different FE models, depending on physical phenomena to be analyzed, electrostatic analysis and stress analysis and so on. The FE models are then exported to the FE analysis code, and then analyses are peformed. Then, analytical analysis and FE analysis about the torque generated by electrostatic micro motor are performed. The starting torque is proportional to $V^2$, the calculated starting torque from the two-dimensional analytical solutions are three times larger than those from the three-dimensional FE solutions.

  • PDF

Influence of Cogging Torque Reduction Method on Torque Ripple in a Surface-Mounted Permanent Magnet Synchronous Motor

  • Kim, Tae-Woo;Chang, Jung-Hwan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.109-114
    • /
    • 2012
  • The torque characteristics of a surface-mounted permanent magnet synchronous motor (SPMSM) are analyzed in this study. The harmonics of the back electromotive force (EMF) and cogging torque are analyzed by the finite element method to study their effects on the torque ripple. Although low cogging torque can be achieved by varying geometric parameters such as the permanent magnet (PM) offset and notch depth on the stator teeth, the torque ripple is increased in some cases. The analysis results show that the ripple of the generated torque is determined by not only the amplitudes but also the phases of harmonics for the back EMF and cogging torque.

Effect of tightening torque on the connection stability of a custom-abutment implant system: 3D finite element analysis (지대주 나사 조임 토크가 맞춤형 지대주 임플란트 시스템의 연결부 안정성에 미치는 영향: 3차원 유한 요소 해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.99-105
    • /
    • 2021
  • Purpose: This study aims to examine the stress distribution effect of tightening torques of different abutment screws in a custom-abutment implant system on the abutment-fixture connection interface stability using finite element analysis. Methods: The custom-abutment implant system structures used in this study were designed using CATIA program. It was presumed that the abutment screws with a tightening torque of 10, 20, and 30 N·cm fixed the abutment and fixture. Furthermore, two external loadings, vertical loading and oblique loading, were applied. Results: When the screw tightening torque was 10 N·cm, the maximum stress value of the abutment screw was 287.2 MPa that is equivalent to 33% of Ti-6Al-4V yield strength. When the tightening torque was 20 N·cm, the maximum stress value of the abutment screw was 573.9 MPa that is equivalent to 65% of Ti-6Al-4V yield strength. When the tightening torque was 30 N·cm, the maximum stress value of the abutment screw was 859.6 MPa that is similar to the Ti-6Al-4V yield strength. Conclusion: As the screw preload rose when applying each tightening torque to the custom-abutment implant system, the equivalent stress increased. It was found that the tightening torque of the abutment influenced the abutment-fixture connection interface stability. The analysis results indicate that a custom-abutment implant system should closely consider the optimal tightening torque according to clinical functional loads.

Reduction and Analysis for Cogging Torque of Permanent Magnet Synchronous Generators with Multi-Pole Rotor for Wind Power Application (풍력발전용 영구자석 다극 동기발전기의 코깅토크의 해석 및 저감)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2008
  • This paper deals with reduction and analysis of cogging torque for permanent magnet synchronous generators with multi-pole rotor for wind power applications. Open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions, we also derive open-circuit field solutions considering stator slotting effects. By using open-circuit field solutions considering stator slotting effects and energy variation methods, this paper analytically predicts the cogging torque considering skew effects. All analytical results are shown in good agreement with those obtained from finite element (FE) analyses. In order to reduce the cogging torque, by predicting the variation of the cogging torque according to pole arc/pitch ratio using analytical and FE methods, pole arc/pitch ratio which makes the cogging torque minimum are determined. However, we confirm that measured value for cogging torque of the PMG with determined pole arc/pitch ratio is twice higher than predicted value. Therefore, the reason for an error between measured and predicted cogging torque is discussed in terms of a shape of PMs and is proved experimentally.