• 제목/요약/키워드: Tooth Strength

검색결과 354건 처리시간 0.023초

Development of the Sub Gear for the Scissors Gear System for Automobile Engines

  • Nakazawa, Katsuhito;Nagata, Toshihiko;Motooka, Naoki
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.756-757
    • /
    • 2006
  • P/M enables the economical production of components for many kinds of gears. Functionally, the sub gear requires high tooth accuracy and bending fatigue strength. The whole tooth profile was sized after sintering to satisfy the gear tooth accuracy specification. The part was redesigned to reduce machining requirements. The required bending fatigue strength was achieved through appropriate material choice and induction of compressive residual stress by shotpeening after carburizing. The P/M sub gear replaced a forged steel gear, satisfied performance requirements, expanded the use of P/M applications and provided over 30% cost reduction.

  • PDF

DLP방식의 치과용 3D프린팅 임시치아 소재의 기계적 특성 (Mechanical Properties of DLP-type Dental 3D Printing Temporary Tooth Material)

  • 정효경;이승희;정효경
    • 한국산업융합학회 논문집
    • /
    • 제24권3호
    • /
    • pp.373-376
    • /
    • 2021
  • Tested the flexural strength and maximum load of two types of dental 3 D printed temporary tooth materials of the DLP method. The average flexural strength was 206.98 MPa in the test group and 139.77 MPa in the control group. The average flexural strength of the experimental group was 67.21 MPa higher than that of the control group. In the maximum load experiment, an average of 44.16N in the experimental group and 37.31N in the control group were measured. The average value of 6.85N was higher in the experimental group, and the durability of the artificial tooth restoration was improved.

Evaluation of shear bond strengths of gingiva-colored composite resin to porcelain, metal and zirconia substrates

  • An, Hong-Seok;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.166-171
    • /
    • 2011
  • PURPOSE. The purpose of this study is to evaluate and compare the shear bond strength of the gingiva-colored composite resin and the tooth-colored composite resin to porcelain, metal and zirconia. MATERIALS AND METHODS. Sixty cylindrical specimens were fabricated and divided into the following 6 groups (Group 1-W: tooth-colored composite bonded to porcelain, Group 1-P: gingiva-colored composite bonded to porcelain, Group 2-W: tooth-colored composite bonded to base metal, Group 2-P: gingiva-colored composite bonded to base metal, Group 3-W: tooth-colored composite bonded to zirconia, Group 3-P: gingiva-colored composite bonded to zirconia). The shear bond strength was measured with a universal testing machine after thermocycling and the failure mode was noted. All data were analyzed using the two-way analysis of variance test and the Bonferroni post-hoc test at a significance level of 0.05. RESULTS. The mean shear bond strength values in MPa were 12.39, 13.42, 8.78, 7.98, 4.64 and 3.74 for Group 1-W, 1-P, 2-W, 2-P, 3-W and 3-P, respectively. The difference between the two kinds of composite resin was not significant. The shear bond strength of Group 1 was the highest and that of Group 3 was the lowest. The differences among Group 1, 2 and 3 were all significant (P<.05). CONCLUSION. The shear bond strength of the gingiva-colored composite was not less than that of the tooth-colored composite. Thus, repairing or fabricating ceramic restorations using the gingiva-colored composite resin can be regarded as a practical method. Especially, the prognosis would be fine when applied on porcelain surfaces.

조속식 감속기(Harmonic Drive)의 설계에 관한 연구

  • 전완주;오박균
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1989년도 제10회 학술강연회초록집
    • /
    • pp.78-85
    • /
    • 1989
  • Conventional theory of gear mechanism can not be applied to analyze the harmonic drive due to specific movement of the tooth. Therefore, external tooth profile can't be manufactured by conventional exclusive tools which have pressure angle of 20$\circ$C. This paper deals with an analysis of kinematics and strength analysis of tooth. Then a theoretical new tooth profile of the flexspline and method of manufacture of external tooth profile are presented.

  • PDF

치과용 지르코니아 이장재 처리에 따른 지르코니아와 도재의 전단결합강도 비교 (Shear bond strength of a layered zirconia and porcelain according to treatment of zirconia liner)

  • 서정일;박원욱;김양근
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.43-52
    • /
    • 2017
  • Purpose: Physical and chemical properties of gold is most suitable to be restored of teeth to its original state. Recently zirconia was used instead of gold because of esthetical and intimacy of human body. Because of high strength and high abrasion resistance of zirconia, all zirconia artificial tooth lead to wear the original tooth of opposite site. To preserve this original tooth, zirconia artificial tooth covered with dental ceramic glass was used. When joining the zirconia core and dental ceramic glass, difference of their thermal expansion coefficient and wetting ability is generated the residual stress at interface lead to crack. In order to solve this problem, intermediate layer what is called zir-liner was imported to decrease the residual stress and increase the bonding strength. Methods: In this study, to identify the optimum conditions for manufacturing process, various methods to rough the surface of zirconia core were adopted, and vary the thickness of interlayer, and analyzed bond strength. Results: Bond strength of sanding specimens group showed higher than that of non-sanding specimens group, and once applied intermediate layer with sanding specimens showed highest bond strength with 28 MPa. SEM photomicrographs of zirconia cores fired at $1500^{\circ}C$ showed parallel straight lines in sanding and pockmarked surface in blasting surfaces as abrasion traces. Observation of the destruction section after shear test by SEM were carried out. Liner applied non-sanding group and non-liner applied sanding group all showed interfacial crack. Sandblasting group with non-liner showed remained dental ceramic glass on the surface of zirconia. Sandblasting group with once applied liner showed partially remained liner and dental ceramic glass on the surface of zirconia. XRD analysis revealed that sandblasting group showed higher monoclinic peaks than other specimens group and this result was due to the high collision energy for stress induced phase transformation. Conclusions: A study on the improvement of bonding strength between zirconia and dental ceramic glass steadily carried out for the future to practical use.

Analysis of Correlation among Oral Environment, Oral Myofunction, and Oral Microorganisms

  • Kim, Seol-Hee
    • 치위생과학회지
    • /
    • 제19권2호
    • /
    • pp.96-106
    • /
    • 2019
  • Background: Factors affecting oral function include tooth number, oral muscle strength, and oral diseases. This study aimed to investigate the relationship among oral environment, muscle, and microbiology. Methods: Fifty-six elderly individuals in a day care center were included in the study. The survey regarding tongue and lip muscle strength and oral microorganisms was conducted from November to December 2018. Results: Tongue and lip muscle strength were greater in men than women (p>0.05). Tongue muscle strength was greater in the ${\leq}80-year-old$ group ($34.94{\pm}9.85$) than the ${\geq}90-year-old$ group ($25.57{\pm}7.54$) (p<0.05). Tongue muscle strength and lip muscle strength were greater in the ${\geq}15$ functional teeth group ($34.08{\pm}9.31$ and $9.25{\pm}1.63$, respectively) than in the <15 functional teeth group ($28.08{\pm}7.53$ and $7.76{\pm}1.51$, respectively) (p<0.05). Age was significantly correlated with functional tooth number, denture use, and tongue muscle strength. The number of functional teeth was positively correlated with tongue muscle strength, lip muscle strength, and oral microorganisms. Denture use was negatively correlated with tongue and lip muscle strength. Tongue muscle strength was significantly correlated with lip muscle strength. The number of Eubacterium nodatum was higher in men than women. The number of Parvimonas micra and Enterococcus faecalis was higher in the groups with ${\geq}15$ functional teeth, denture use, and greater tongue and lip muscle strength. The number of Lactobacillus casei was higher in the group that uses dentures and with greater tongue strength. Conclusion: Oral microbiology is more important in oral environment and management than oral muscle function. The correlation between oral muscle and oral microorganism requires further study. Therefore, oral care training should be conducted to improve the oral care practice of elderly individuals, maintain oral health through oral care, and prevent the decrease in saliva secretion by aging.

치차성능의 최적성과 강건성을 고려한 치차제원 및 치면수정의 설계 (Design of Gear Dimension and Tooth Flank Form for Optimal and Robust Gear Performance)

  • 배인호;정태형
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.79-86
    • /
    • 2004
  • Tooth errors inevitable in the manufacturing process have large effect on the strength/durability and vibration performances of gear drives. We show that the manufacturing errors affect the overall gear performances, especially vibration performance, and propose a robust optimal design method for gear dimension and its tooth flank form that guarantees reliable performances to the variation of manufacturing errors. This method begins with a search of optimal design candidates by using the previously developed gear optimal design method for the strength/durability and vibration performances. Then, the statistical analysis method is applied to find a robust design solution for the vibration performance which is generally very sensitive to the manufacturing variations.

유성기어 감속기에서 전위계수가 기어 강도에 미치는 영향 (The Effect of Addendum Modification Coefficient on Gear Strength to Planetary Gear Reducer)

  • 곽기석;한동섭
    • 한국기계가공학회지
    • /
    • 제10권4호
    • /
    • pp.38-43
    • /
    • 2011
  • Industrial reducer is in general use to Deck Crane. High-precision and high-efficient reducer is minimized the power-loss and energy-loss of a machine. So it contribute the price reduction and life extension. Reducer is usually using the Planetary gear reducer. Planetary gear reducer is composed the sun gear, planet gear, internal gear and casing. Industrial reducer's wear and breakage have a short-life. To solve this problem, it is using the profile-shifted-gear or tooth modification. This study was carried out the effect of addendum modification coefficient on tooth fillet bending strength to planetary reducer. Tooth fillet bending stress is calculate. And all parameter were expressed the function of addendum modification coefficient. And then stress concentration factor of tooth fillet curve was express the function of addendum modification coefficient using comparison between theory and finite element analysis.

Effects of Dipping in Tooth Reserving Solution on Bond Strength of 4-META/MMA-TBB Dentin Bonding System.

  • Kubota, M.;Yanagidani, T.;Hashimoto, M.;Kudou, Y.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.569.1-569
    • /
    • 2001
  • The purpose of this investigation was to determine the effect of dipping in tooth reserving solution on bond strength of 4-META/MMA-TBB dentin bonding system. The flattened dentin surface of bovine lower incisor was used for this investigation. The tooth were dipped in the tooth reserving solution (ViaSpan; Du Pont Pharmatical / Teeth Server "NEO";Neo Dental Chemical products CO/LTD, Japan/ Saline, Fuso Chemical CO, LTD, Japan) for 30 min.(omitted)

  • PDF

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.