• Title/Summary/Keyword: Tm(III)

Search Result 103, Processing Time 0.027 seconds

Preparation of Fe4[Fe(CN)6]3 Coated on Mica or TiO2/Mica for Infrared Reflective Blue Pigments and Isolation-heat Properties of These Paints (Fe4[Fe(CN)6]3가 코팅된 Mica 또는 TiO2/Mica 적외선 반사용 청색안료 제조 및 이 도료의 차열 특성 평가)

  • Jung, Ha-Young;Kim, Dae Sung;Lee, Hyun-Jin;Lee, Seung-Ho;Lim, Hyung Mi;Choi, Byung-Ki;Kang, Kwang-Jung;Choi, Jin-Sub
    • Korean Journal of Materials Research
    • /
    • v.23 no.12
    • /
    • pp.672-679
    • /
    • 2013
  • $Fe_4[Fe(CN)_6]_3$ coated on a mica or $TiO_2$/mica surface as infrared reflective blue pigment was prepared by a hydrothermal method. $Fe_4[Fe(CN)_6]_3$, used as coloring agent, was uniformly coated on mica or $TiO_2$/mica under the optimized condition of a 1.2 : 1 weight ratio between iron(III) chloride hexahydrate and potassium ferrocyanidetrihydrate at the initial pH level of 4.5 at $70^{\circ}C$. The infrared (IR)-reflective pigments were characterized by SEM, Zeta-potenial, FT-IR, and UV-VIS NIR spectrophotometry. Especially the CIE color coordinate and total solar reflectance(TSR) properties of the pigments were investigated in relation to variation of the coating and coated substrate thicknesses. Isolation-heat paint was prepared with 20 wt% blue pigments fully dispersed in acryl-urethane resin and several additives to coat the film uniformly. The films were also measured with CIE color coordinate, TSR, and the surface temperature was recorded by an isolation-heat measuring system. The pigments and films of $Fe_4[Fe(CN)_6]_3$ coated on mica and $TiO_2$/mica showed high TSR values compared with the TSR value of $Fe_4[Fe(CN)_6]_3$ itself. According to the increase of TSR value, the property of isolation-heat is effective. To realize the optimal blue color, we applied the the pigment to $TiO_2$ coated mica(TM(b)) which has blueish interference color. The pigment of $Fe_4[Fe(CN)_6]_3$ coated on TM(b) shows a strong blue color compared with that of $Fe_4[Fe(CN)_6]_3$ coated on $TiO_2$/Mmca(TM(w)), which has a whitish interference color.

Electrooptic Modulator with InAs Quantum Dots (InAs/InGaAs 양자점을 이용한 전계광학변조기)

  • Ok, Seong-Hae;Moon, Yon-Tae;Choi, Young-Wan;Son, Chang-Wan;Lee, Seok;Woo, Deok-Ha;Byun, Young-Tae;Jhon, Young-Min;Kim, Sun-Ho;Yi, Jong-Chang;Oh, Jae-Eung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.278-284
    • /
    • 2006
  • We have fabricated and measured electrooptic modulator using coupled stack InAs/InGaAs quantum dots. The height of the quantum dot is 16 nm and quantum dots are stacked including an InGaAs capping layer. The peak wavelength of photoluminescence is 1260 nm at room temperature and 1158 nm at 12 K. The operation characteristics of the quantum dots show high modulation efficiency of electrooptic modulator at 1550 nm compared to that of existing III-V bulk and MQW type semiconductor. The measured switching voltage ($V\pi$) is 540 and 600 mV, for TE mode and TM mode, respectively. From the results, the modulation efficiency can be determined as 333.3 and $300^{\circ}/V{\cdot}mm$ for TE and TM modes. The results reported here may lead to the design and fabrication of a novel electrooptic modulator with low switching voltage and high efficiency.

Crystal Structures and Thermal Properties of 2,6-Dinitrophenol Complexes with Lanthanide Series

  • Kim, Eun-Ju;Kim, Chong-Hyeak;Kim, Jae-Kyung;Yun, Sock-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1157-1161
    • /
    • 2008
  • 2,6-Dinitrophenol (2,6-DNP) complexes with lanthanide series including yttrium (except Pm, Tm, and Lu) have been synthesized and their crystal structures have been analyzed by X-ray diffraction methods. Singlecrystal X-ray structure determinations have been performed at 296 K on the Ce$\rightarrow$Yb species and shown them to be isomorphous, triclinic, P1, a = 8.6558(2)$\rightarrow$8.5605(3) $\AA$, b = 11.8813(3)$\rightarrow$11.6611(4) $\AA$, c = 13.9650(3) $\rightarrow$13.8341(5) $\AA$, $\alpha$ = 73.785(1)$\rightarrow$73.531(2)o, $\beta$ = 74.730(1)→74.903(2)${^{\circ}}$, $\gamma$ = 69.124(1)→ 69.670 $(2){^{\circ}}$, V = 1266.86(5)→1221.53(7) $$\AA^{3}$$, Z = 2. In Ln(III) complexes, three 2,6-DNP ligands coordinate directly to the metal ion in the bidentate fashion. The nine coordinated Ln(III) ion forms slightly distorted tri-capped trigonal prism. There are no water molecules in the crystal lattice. The dependences of metal to ligand bond lengths are discussed on the atomic number of lanthanide elements. The thermal properties of lanthanide complexes of 2,6- DNP have also studied by TG-DTG and DSC thermal analysis methods.

Effect of various intraoral repair systems on the shear bond strength of composite resin to zirconia

  • Han, In-Hae;Kang, Dong-Wan;Chung, Chae-Heon;Choe, Han-Cheol;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.248-255
    • /
    • 2013
  • PURPOSE. This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS. Thirty zirconia specimens were divided into three groups according to the repair method: Group I-CoJet$^{TM}$ Repair System (3M ESPE) [chairside silica coating with $30{\mu}m$ $SiO_2$ + silanization + adhesive]; Group II-Ceramic Repair System (Ivoclar Vivadent) [etching with 37% phosphoric acid + Zirconia primer + adhesive]; Group III-Signum Zirconia Bond (Heraus) [Signum Zirconia Bond I + Signum Zirconia Bond II]. Composite resin was polymerized on each conditioned specimen. The shear bond strength was tested using a universal testing machine, and fracture sites were examined with FE-SEM. Surface morphology and wettability after surface treatments were examined additionally. The data of bond strengths were statistically analyzed with one-way ANOVA and Tamhane post hoc test (${\alpha}$=.05). RESULTS. Increased surface roughness and the highest wettability value were observed in the CoJet sand treated specimens. The specimens treated with 37% phosphoric acid and Signum Zirconia Bond I did not show any improvement of surface irregularity, and the lowest wettability value were found in 37% phosphoric acid treated specimens. There was no significant difference in the bond strengths between Group I ($7.80{\pm}0.76$ MPa) and III ($8.98{\pm}1.39$ MPa). Group II ($3.21{\pm}0.78$ MPa) showed a significant difference from other groups (P<.05). CONCLUSION. The use of Intraoral silica coating system and the application of Signum Zirconia Bond are effective for increasing the bond strength of composite resin to zirconia.

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

COMPARATIVE STUDY ON FLUORIDE RELEASE AND RE-UPTAKE CAPACITY OF SEVERAL FLUORIDE-RELEASING RESTORATIVE MATERIALS (수종의 수복재의 불소 적용법에 따른 불소 유리에 관한 비교 연구)

  • Lee, Yeon-Ho;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.25-34
    • /
    • 2006
  • Fluoride released from dental restorative materials effectively declines the incidence and activity of dental caries and inhibits tooth demineralization. This study investigated the fluoride release and uptake characteristics of one composite resin $(Z-250^{TM})$ three glass ionomer-based restorative material ($Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$, Fuji IX GP $Fast^{(R)}$) Forty discs(6mm diameter and 1mm height) were prepared for each material. Each disc was immersed in 5ml of distilled water within polyethylene vial and stored at $37^{\circ}C$. The distilled water was changed every 24 hours and the release of fluoride was measured for 31 days. At the end of this period, each specimen was subjected to one of four treatments : (A) no fluoride treatment (control), (B) application of a fluoride dentifrice (500ppm) for three minutes three times; (C) application of the 1.23% acidulated phosphate fluoride(APF) foam for one minute once, (D) the same regimen as (B), plus application of the APF foam for one minute once. Then, all samples were reassessed for an additional 7 days. For all samples, the greatest fluoride release was observed after the first day of the study but diminished with time. On the 7th day of the study, fluoride release level was stabilized. Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ released higher amount of fluoride than other materials ; however, no statistically significant difference was found from Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$. The amount of fluoride of $Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ was increased after fluoride treatment, and diminished with time.

  • PDF

A Study of Characteristics of lnxGa1-xP by Photoreflectance measurement (Photoreflectance 측정에 의한 InxGa1-xP의 특성 연구)

  • Kim D. L.;Yu J. I.
    • Laser Solutions
    • /
    • v.8 no.3
    • /
    • pp.5-10
    • /
    • 2005
  • [ $InxGa_{1-x}P/GaAs$ ] structures were grown by chemical beam epitaxy(CBE), Pure phosphine($PH_3$) gases were used as group V sources. for the group III sources, TEGa, TmIn were used. $InxGa_{1-x}P$ epilayer was grown on SI-GaAs substrate and has a 1-${\mu}m$ thick. We have investigated the characteristics of $InxGa_{1-x}P$ by the photoreflectance(PR) spectroscopy, The PR spectrum of $InxGa_{1-x}P$ shows third-derivative feature whose Peaks Provide energy gap. The energy gap of $InxGa_{1-x}P$ has deduced composition x. From temperature dependance of PR spectra, temperature coefficient is $dEg/dT=-3.773{\times}10^{-4}$ eV/K, and Varshni coefficients $\alpha$ and $\beta$ values obtained $4{\times}10^4$ eV/K and 267 K respectively. Also, interaction $\alpha$B was 19.4 meV using the Bose-Einstein temperature relation, and $\Theta$ value related the average phonon frequency were 101.4 K. In particular, shoulder peak related to defects observed in PR signal that measured in temperature 82 K.

  • PDF

Low Prewwure MOCVD Growth and Characterization of $Ga_xIn_{1-x}P$ Grown on (100) GaAs Substrates (저압 MOCVD법에 의한 (100)-GaAs 기판위의 $Ga_xIn_{1-x}P$ 성장과 특성)

  • 전성란;손성진;조금재;박순규;김영기
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.1
    • /
    • pp.94-102
    • /
    • 1994
  • x- 0.51인 GaxIn1-x-P 에피층을 저압 MOCVD 성장법으로 TEGa(triethylgallium) TmIn(trimethylindium)등의 MO(metalorganic) 원료와 PH3(phosphine)를 사용하여 GaAs(100) 기판위에 성장하였다. 성장조건에 의한 표면 morphology 결정결함 성분비 PL spectra 운반자 농도와 이동도 및 DLTS spectra와 같은 성장층의 특성을 관찰하였다, $650^{\circ}C$의 성장온도와 V/III비, 즉 TEGa와 TMIn 두 원료의 유량에 대한 PH3 의유량변화에 아무런 영향을 받지 않음을 알 수 있었다. Ga0.51In0.49P에피층과 기판의 격자상수 차에 의한 격자 부정합 $\Delta$a /a0은 약 (3.7~8.9)x10-4 이었으며 실온과 5Kd서 에피층의 PL 피크 에너지는 각각 1.85eV와 1.9eV였다. 성장층의 운반자 농도와 이동도는 V/III 비에 따라 달라지 는데 그비가 120에서 220으로 증가함에 따라 농도는 1.8x1016cm-3에서 8.2x1016cm-3로 증가하였고 이동도 는 1010cm/V.sec에서 366cm/V.sec로 감소하였다.

  • PDF

Beneficial Effects of Growth Hormone Treatment in Prader-Willi Syndrome

  • Kim, Jinsup;Yang, Aram;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.2
    • /
    • pp.41-43
    • /
    • 2017
  • Prader-Willi syndrome (PWS) is a genetic disorder that is considered, especially on child, to cause poor feeding, hypotonia, failure to thrive, developmental delay and hypogonadism which is known to affect between 1 in 10,000 and 30,000 people. The children with PWS are viewed as affected by growth hormone (GH) insufficiency, although the exact mechanisms of GH deficiency are not fully understood. However, the benefits of GH treatment in children with PWS are well established. Myers, et al. (2006), Grugni, et al. (2016) indicated its positive effects on linear growth, body composition, motor function, respiratory function and psychomotor development. Despite of its effectiveness and advantages had been well known and proven in many other studies, there is only one recombinant GH product that is approved for PWS in Korea, $Genotropin^{(R)}$, till now. A phase III clinical study of GH treatment with $Eutropin^{TM}$, in 34 Korean PWS children is in progress, which is expected to have comparable effects and safety profile with the active control by assessing auxological changes such as height standard deviation score, body composition changes such as lean body mass and percent body fat, motor and cognitive development using Bayley scale, and safety profiles.

FLUORIDE RELEASE AND MICROHARDNESS OF GIOMER ACCORDING TO TIME (Giomer의 불소 유리 양상 및 미세경도에 관한 연구)

  • Kim, Sang-Min;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.429-437
    • /
    • 2010
  • The aim of this study was to evaluate the fluoride release and microhardness of Beautifil II as giomer(Group I), F2000 Compomer as compomer(Group II), GC Fuji II LC Capsule as resin-modified glass ionomer(Group III) and $Filtek^{TM}$ Z350 as composite resin(Group IV) according to time. Forty discs(5 mm diameter and 2 mm height) were prepared for each material. Each disc was immersed in 3 ml of de-ionized water within polyethylene tube and stored at $37^{\circ}C$. Evaluations were performed by pH/ISE meter for analysis of fluoride release and hardness testing machine for analysis of microhardness over 31 days. The results can be summarized as follows : 1. For all groups except group IV, the greatest fluoride release was observed after the first day of the study period and then dramatically diminished over time. On the 7th day of the study period, fluoride release level was stabilized. 2. Group III showed the highest fluoride release among test groups and then group II, group I were followed. Significant difference in cumulative fluoride release over 31 days was found between each groups. Group IV showed no fluoride release during study period. 3. Group IV showed the highest microhardness among test groups and then group I, group II, group III were followed. Significant difference in microhardness was found between each group, except between group I and group II. 4. After 31 days, microhardness was slightly diminished in every group. However, no significant difference was found.