• Title/Summary/Keyword: Tissue Doppler imaging

Search Result 27, Processing Time 0.032 seconds

Ultrasonic Measurement of Tissue Motion for the Diagnosis of Disease

  • Beach Kirk W.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.3-12
    • /
    • 2003
  • Ultrasonic pulsed Doppler velocimetry has become a standard international method of classifying carotid disease. Because the measured angle adjusted velocity increases as the Doppler angle increases, examinations should be performed at a convenient standard Doppler examination angle. An angle of 60 degrees is achievable throughout most examinations. Multiple Doppler viewing angles allow the acquisition of velocity vectors during the cardiac cycle, revealing the complex velocity patterns. Ultrasonic velocimetry (whether Doppler or time domain) is based on changes in the phase of the ultrasound echo. Other examinations can be done based on the echo phase. Slow motions of organs such as the brain can be used to monitor changes in edema. Measurements of tissue strain due to the pulsatile filling of the arterioles. This plethysmographic imaging method can display differences in tissue perfusion because of different tissue types and changes in autonomic activity.

  • PDF

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Velocity Vector Imaging (속도 벡터 영상 방법)

  • Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1E
    • /
    • pp.11-27
    • /
    • 2010
  • Nowadays, ultrasound Doppler imaging is widely used in assessing cardiovascular functions in the human body. However, a major drawback of ultrasonic Doppler methods is that they can provide information on blood flow velocity along the ultrasound beam propagation direction only. Thus, the blood flow velocity is estimated differently depending on the angle between the ultrasound beam and the flow direction. In order to overcome this limitation, there have been many researches devoted to estimating both axial and lateral velocities. The purpose of this article is to survey various two-dimensional velocity estimation methods in the context of Doppler imaging. Some velocity vector estimation methods can also be applied to determine tissue motion as required in elastography. The discussion is mainly concerned with the case of estimating a two-dimensional in-plane velocity vector involving the axial and lateral directions.

Echocardiographic Evaluation of Cardiovascular Function in Cloned Dogs (심장 초음파를 이용한 복제견의 심혈관계 기능 평가)

  • Yeo, Ju-Hwan;Kim, Jae-Hwan;Kim, So-Young;Lee, Seung-Jun;Park, Noh-Won;Oh, Hyun-Ju;Kim, Min-Jung;Kim, Geon-A;Jo, Young-Kwang;Lee, Byeong-Chun;Eom, Kidong
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.301-307
    • /
    • 2015
  • The purpose of this study was to compare echocardiographic parameters of cloned beagle dogs with the previously reported reference range. Seven cloned dogs were assessed for anatomical features and cardiac function through left- and right-sided heart and right ventricle outflow tract from M-mode, 2D-mode, pulsed wave Doppler and tissue Doppler imaging. In all the cloned dogs, there were no abnormalities in anatomical structure and measurements were within the normal reference range. In addition, left- and right-sided myocardial function was within the normal reference range. Especially, pulmonary hypertension and right-sided heart failure frequently encountered in cloned animals were not recognized in cloned dogs. In conclusion, no evidence of cardiovascular dysfunction in mature cloned dogs could be identified either at birth or the growing stage in this study. Therefore, serious adverse effects of somatic cell nuclear transfer technology including transgenesis on cardiac morphology and function were not found in cloned dogs.

Modified Tei index in patients with Kawasaki disease by tissue doppler imaging (가와사키병 환아에서 Tissue doppler imaging으로 측정한 modified Tei 지수)

  • Kim, Hee Jung;Cha, Jung Hwa;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1202-1210
    • /
    • 2006
  • Purpose : A quantitative and easily measured Doppler index of combined systolic and diastolic ventricular myocardial performance (Tei index) was recently proposed as a potentially useful predictor of global myocardial performance. However, presence of heart rate fluctuation makes it unreliable. Therefore, the modified Tei index was introduced by using tissue Doppler imaging (TDI) which enables measuring contraction and relaxation velocities from myocardium simultaneously. The purpose of this study was to investigate the effectiveness of the modified Tei index in the evaluation of global cardiac function. Methods : Forty eight patients in the acute phase of Kawasaki disease (KD) were studied. These patients were divided into two groups according to the modified Tei index. TDI and conventional echocardiography were performed. Systolic velocity, systolic displacement, E' velocity, E' displacement, A' velocity and A' displacement were measured at the base, mid-septum and the apex of the interventricular septum. Ejection fraction (EF), Tei index and modified Tei index were estimated. Results : Modified Tei index correlated negatively with systolic displacement, E' displacement and A' displacement at the base. Modified Tei index correlated positively with ESR and CRP. EF and Tei index were normal in KD patients. Conclusion : Modified Tei index is a safe, feasible and sensitive index for evaluating global ventricular functions in spite of normal EF and Tei index in KD.

Assessment of neovascularization during bone healing using contrast-enhanced ultrasonography in a canine tibial osteotomy model: a preliminary study

  • Jeon, Sunghoon;Jang, Jaeyoung;Lee, Gahyun;Park, Seungjo;Lee, Sang-kwon;Kim, Hyunwook;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.10.1-10.12
    • /
    • 2020
  • Blood perfusion of skeletal muscle and callus was evaluated using contrast-enhanced ultrasonography (CEUS) in a canine osteotomy model to determine the applicability of CEUS in the assessment of neovascularization during fracture healing and to compare the vascular signals on CEUS between external skeletal fixation and cast-applied dogs. In 6 Beagle dogs, a simple transverse osteotomy was performed at the left tibial shaft and external skeletal fixation (n = 3) or a cast (n = 3) was applied. Radiography, power Doppler ultrasonography (power Doppler), and CEUS were performed until complete union was achieved. On CEUS, vascular changes were quantitatively evaluated by measuring peak intensity (PI) and time to PI in the soft tissue and callus and by counting the vascular signals. Vascular signals from the soft tissue were detected on power Doppler and CEUS on day 2. Significantly more vascular signals were detected by CEUS than by power Doppler. On CEUS, PI in the surrounding soft tissue was markedly increased after the fracture line appeared indistinctively changed on radiography in all dogs. In the cast-applied dogs, vascular signals from the periosteal and endosteal callus were detected on CEUS before mineralized callus was observed on radiography. CEUS was useful in assessing the vascularity of soft tissue and callus, particularly in indirect fracture healing, and provided indications of a normally healing fracture.

Assessment of cardiac function in syncopal children without organic causes

  • Kim, Heoungjin;Eun, Lucy Youngmin
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.11
    • /
    • pp.582-587
    • /
    • 2021
  • Background: Syncope is a common problem in children and adolescents. However, a large proportion of syncope cases have no underlying cause. Purpose: This study aimed to identify the factors affecting the severity of syncope using tissue Doppler imaging (TDI). Methods: This retrospective study included 61 children and adolescents with syncope who underwent echocardiography. The head-up-tilt test (HUT) was performed when there was a more severe syncopal event. We compared the echocardiographic findings between the execute HUT and nonexecute HUT, negative HUT result and positive HUT result, and normal electrocardiogram (ECG) and abnormal ECG groups. Data were analyzed using an unpaired t test post hoc analysis. Results: In the execute and nonexecute HUT groups, the odds ratios were 0.55 for medial E/E' (P=0.040) and 0.64 for lateral E/E' (P=0.049). Comparison of the results of the decreased, normal, and increased groups for lateral E/E' revealed a significant difference in the execution HUT and nonexecute HUT groups (overall, P=0.004; decreased vs. increased, P=0.003; normal vs. increased, P=0.050). Conclusion: Medial E/E' and lateral E/E' were decreased in patients with severe syncopal events. These findings suggest that the presence of left ventricular diastolic deterioration may cause hypoperfusion even in the absence of organic causes and, consequently, increase syncope severity and frequency. The TDI measured by echocardiography can be used as an index to predict syncope recurrence and/or severity.

A case of constrictive pericarditis presenting with protein-losing enteropathy (단백 소실성 장병증을 동반한 교착성 심낭염 1례)

  • Hong, Jeong Mi;Lee, Jae Young;Kim, Soo Jin;Jang, Gi Young;Shim, Woo Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.898-901
    • /
    • 2006
  • Constrictive pericarditis represents a rare cause of protein-losing enteropathy in children. Reported is an 11-year-old girl with protein-losing enteropathy (PLE) as the principal manifestations of constrictive pericarditis. After total pericardiectomy, symptoms and signs of PLE disappeared. Doppler echocardiography including tissue Doppler imaging is a useful noninvasive initial diagnostic tool for differential diagnosis of diastolic heart failure.

Clinical Usefulness of Ultrasonography in Oral and Maxillofacial Regions (구강악안면영역에서 초음파영상 진단)

  • Oh, Song Hee;Choi, Yong-Suk
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.690-699
    • /
    • 2019
  • Ultrasound sonography(US) is used to evaluate various diseases of maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. Nevertheless, the clinical application of US imaging is limited in the dental field. This is due to the lack of knowledge about the US image and the image characteristics of the anatomical structures. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging.

  • PDF