• Title/Summary/Keyword: Time-varying Effect

Search Result 596, Processing Time 0.025 seconds

Communication Under the Shallow Water Using an Equalizer (등화기를 이용한 천해에서의 수중통신)

  • Yoon, Byung-Woo;Shin, Yoon-Ki;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.13-22
    • /
    • 1989
  • Underwater channels can be regarded as time-varying systems in view of the acoustical characteristics due to the fact that the characteristics of the channel are affected by the environmental and geometrical conditions. Especially in shallow water case, the surface and bottom conduct as a waveguide so echo effect due tu the multipath reflections are severe. Therefore in shallow water communications, it is very important to equalize the transmitted signals distorted by the underwater channels with time-varying multipath fading. In this paper an equalizer system which employs the frequency domain adaptive filter to equalize the channels using inverse modeling technique is introduced.

  • PDF

A Study on the Sound Absorption Coefficient by Varying Sample Size (시편의 크기에 따른 흡음계수 변화 연구)

  • 정성수;이우섭;조문재;서상준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.83-88
    • /
    • 2001
  • The sound absorption coefficient of glass wool (bulk density of 48 kg/m:1 and 32 kg/m7) was measured by reverberation room method as varying their cross-sectional area. The results show that the absorption is larger for smaller samples because of edge effect. The absorption coefficient with two different kinds of sources. 1/.7-octave band and while noise, gives similar values.

  • PDF

Detection and Tracking of Time Varying Power System Frequencies and Harmonics using Subband Adaptive Filtering (적응 부밴드 필터링을 이용한 전력계통 시변 주파수와 고조파 검출 및 추적)

  • Sohn, Sang-Wook;Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.679-687
    • /
    • 2009
  • In this paper, a subband filtering and adaptive prediction technique for analyzing harmonics in power systems is presented. In this method, the filter banks are designed to decompose odd and even order harmonics separately. The adaptive prediction has been employed reduce the transient and white noise effect in time varying harmonics detecting and tracking. The frequencies and amplitudes of the decomposed harmonics are estimated by recursive algorithm. To demonstrate the performances of the developed technique, computer simulations to the signal with the time-varying frequency and THD are carried out.

A Study on the Harmonics Effect of SVC in Electric Arc Furnace Loads

  • Kim, Kyung-Chul;Jin, Seong-Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.54-60
    • /
    • 2006
  • Large steel industries have time-varying nonlinear loads such as electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. The main objective of the static var compensator is to maintain the rms voltage at the point of common coupling within the limit. In this research, harmonic mitigation studies were conducted with and without the SVC, and time-varying harmonics were evaluated according to the international harmonic standards (IEC 61000-3-6 and IEEE Std. 519) using a cumulative probabilistic approach.

On the in-duct acoustical source characteristics of a simplified time-varying fluid machine (시변하는 간단한 유체기계의 덕트 내 음원 특성에 대한 해석적 연구)

  • 이정권;장승호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.517-521
    • /
    • 2001
  • Measurement techniques for the in-duct source characteristics of fluid machines can be classified into direct method and load method, according to whether the technique employs an external acoustic source or not. It has been known that the two methods yield different results and the load method used to come up with a negative source resistance, in spite of the fact that a very accurate prediction of radiated noise can be obtained by using any result. This paper is focused to the effect of time-varying nature of fluid machines on the output result. For this purpose, a simplified fluid machine consisting of a reservoir, a valve and a pipe is considered as representing a typical linear, periodic, time-varying system and the measurement techniques are simulated by utilizing the Hill equation and its steady-state forced response. In the load method, the source impedance turns out being dependent on the valve impedance at the calculation frequency and the valve and load impedances at other frequencies as well.

  • PDF

On Improving Resolution of Time-Frequency Representation of Speech Signals Based on Frequency Modulation Type Kernel (FM변조된 형태의 Kernel을 사용한 음성신호의 시간-주파수 표현 해상도 향상에 관한 연구)

  • Lee, He-Young;Choi, Seung-Ho
    • Speech Sciences
    • /
    • v.12 no.4
    • /
    • pp.17-29
    • /
    • 2005
  • Time-frequency representation reveals some useful information about instantaneous frequency, instantaneous bandwidth and boundary of each AM-FM component of a speech signal. In many cases, the instantaneous frequency of each component is not constant. The variability of instantaneous frequency causes degradation of resolution in time-frequency representation. This paper presents a method of adaptively adjusting the transform kernel for preventing degradation of resolution due to time-varying instantaneous frequency. The transform kernel is the form of frequency modulated function. The modulation function in the transform kernel is determined by the estimate of instantaneous frequency which is approximated by first order polynomial at each time instance. Also, the window function is modulated by the estimated instantaneous. frequency for mitigation of fringing. effect. In the proposed method, not only the transform kernel but also the shape and the length of. the window function are adaptively adjusted by the instantaneous frequency of a speech signal.

  • PDF

Hybrid Interference Cancellation for OFDMA Uplink in Time-Varying Fading Channels (시변 페이딩 채널에서 상향 직교 주파수 분할 다중 접속을 위한 혼합 간섭 제거 기법)

  • Song, Hyung-Joon;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.6
    • /
    • pp.78-85
    • /
    • 2009
  • In time-varying multipath fading channels, orthogonal frequency division multiple access (OFDMA) uplink systems suffer severe performance degradation caused by inter-channel interference (ICI). In this paper, we propose a hybrid interference cancellation (HIC) for suppressing the degradation effect of ICI. The proposed HIC can achieve both exact interference cancellation and low detection complexity through efficient combination of parallel detection and serial cancellation. Simulation results show that, as the effect of Doppler increases, the proposed HIC achieves bit error rate (BER) performance enhancement in compared with severe performance degradation of conventional OFDMA receivers. In addition, both the computational complexity and total detection time are reduced.

Similarity between a stagnant point diffusion flame and an evolving jet diffusion flame (전개확산제트화염과 정체점 확산화염과의 유사성)

  • Park, Jeong;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.494-502
    • /
    • 1997
  • Experiments on corresponding jet flames with stagnant point diffusion flames have been carried out in initial injection periods. A compensated measurement of maximum flame temperature, which is based on the ion signal, has been employed to inspect flame responses to time-varying strain rates. The flame responses are obtained at two conditions for the slowly time-varying strain rate and the case of flame extinction, and analyzed to confirm similarity between a stagnant point diffusion flame and an evolving jet diffusion flame. Nonsteady effects are addressed via the comparison between several time scales. The time variation with low strain rates, in which illustrates the flame behavior of the upper branch far from extinction in the well-known S-curve, is confirmed to produce a quasi-steady flame response through the nonsteady experiments. The time variation with strain rates in the case of flame extinction indicates an unsteady effect of flame response. It is therefore found that the flame responses near jet tip depend on time histories of characterized strain rates in the developing process.

Time-varying characteristics analysis of vehicle-bridge interaction system using an accurate time-frequency method

  • Tian-Li Huang;Lei Tang;Chen-Lu Zhan;Xu-Qiang Shang;Ning-Bo Wang;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • v.33 no.2
    • /
    • pp.145-163
    • /
    • 2024
  • The evaluation of dynamic characteristics of bridges under operational traffic loads is a crucial aspect of bridge structural health monitoring. In the vehicle-bridge interaction (VBI) system, the vibration responses of bridge exhibit time-varying characteristics. To address this issue, an accurate time-frequency analysis method that combines the autoregressive power spectrum based empirical wavelet transform (AR-EWT) and local maximum synchrosqueezing transform (LMSST) is proposed to identify the time-varying instantaneous frequencies (IFs) of the bridge in the VBI system. The AR-EWT method decomposes the vibration response of the bridge into mono-component signals. Then, LMSST is employed to identify the IFs of each mono-component signal. The AR-EWT combined with the LMSST method (AR-EWT+LMSST) can resolve the problem that LMSST cannot effectively identify the multi-component signals with weak amplitude components. The proposed AR-EWT+LMSST method is compared with some advanced time-frequency analysis techniques such as synchrosqueezing transform (SST), synchroextracting transform (SET), and LMSST. The results demonstrate that the proposed AR-EWT+LMSST method can improve the accuracy of identified IFs. The effectiveness and applicability of the proposed method are validated through a multi-component signal, a VBI numerical model with a four-degree-of-freedom half-car, and a VBI model experiment. The effect of vehicle characteristics, vehicle speed, and road surface roughness on the identified IFs of bridge are investigated.

The Effect of Phase Noise from PLL Frequency Synthesizer (PLL 주파수 합성기에서 발생하는 위상잡음의 영향)

  • 조형래;최정수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.865-870
    • /
    • 2001
  • In this paper, we analyse the effect of phase noise from PLL frequency synthesizer on 64 QAM when detecting corrupted signals. To predict the phase noise of an oscillator very accurately, we assume that the oscillator is linearly time-varying when the input impulsive current to the oscillator is small. The performance of the detector which detects the corrupted signal by oscillator phase noise is compared with that when the detector is only affected by AWGN and then analyse how much the phase noise degrades the system performance for 64 QAM.

  • PDF