• Title/Summary/Keyword: Time-Mean Film Thickness

Search Result 19, Processing Time 0.027 seconds

Mixed Lubrication Analysis of Parallel Thrust Bearing by Surface Topography (표면거칠기를 고려한 평행 스러스트 베어링의 혼합윤활 해석)

  • 이동길;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.134-141
    • /
    • 2000
  • The real area of contacts, average film thickness, mean real pressure, and mean hydrodynamic pressure are investigated numerically in this study, especially for the parallel thrust bearing. Model surface is generated numerically with given autocorrelation function and some surface profile parameters. Then the average Reynolds equation contained flow factors and contact factor is applied to predict the effects of surface roughness in mixed lubrication regimes. In this equation, flow factors are defined as correction terms to smooth out high frequency surface roughness and contact factor is introduced to relieve from obtaining the average film thickness. Therefore the computation time to obtain h can be reduced.

  • PDF

Mixed Lubrication Analysis of Parallel Thrust Bearing Considering Surface Roughness (표면거칠기를 고려한 평행 스러스트 베어링의 혼합윤활 해석)

  • 이동길;임윤철
    • Tribology and Lubricants
    • /
    • v.16 no.6
    • /
    • pp.455-460
    • /
    • 2000
  • The real area of contacts, average film thickness, mean real pressure, and mean hydrodynamic pressure are investigated numerically in this study, especially for the parallel thrust bearing. Model surface is generated numerically with given autocorrelation function and some surface profile parameters. Then the average Reynolds equation contained flow factors and contact factor is applied to predict the effects of surface roughness in mixed lubrication regimes. In this equation, flow factors are defined as correction terms to smooth out high frequency surface roughness and contact factor is introduced to relieve from obtaining the average film thickness. Therefore the computation time to obtain barh h can be reduced.

Local Mean Water Layer Thickness in Countercurrent Stratified Two -Phase Fllow (물-증기 역류 성층이상유동에서의 국부 평균 액체층 두께)

  • Kim, Hho-Jung;Kim, Kap
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.947-958
    • /
    • 1986
  • 물-증기 역류 성층이상유동에서의 평균 액체층 두께가 여러가지 경사각과 종횡비에 따라 측정되었다. 난류유동에 있어서 전단응력분포의 선형화와 von Karman의 혼합길이 이론을 근거로 평균 액체층의 두께에 대한 관계식이 제시되었으며 실험결과와 잘 일치하였음을 보였다. 접촉면에서의 조파저항이 고려되지 않은 해석결과는, 수평 성층유동의 경우에, 평균 액체층 두께보다는 오히려 파곡까지의 액체층 두께를 예측하고 있는 것으로 나타났다. 또한 평균 액체층 두께에 대한 실험 상관관계식이 계산시 편의를 위해 쉽게 인지할 수 있는 매개변수들의 항들롤 제시되었다.

액체미립화에 관한 실험적 연구

  • 이규영;신명순;양옥룡
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.4
    • /
    • pp.57-66
    • /
    • 1985
  • This paper deals with an experimental study on a liquid atomization to investigate the break- up mechanism of a liquid film flow which is formed by a high speed air flow in parallel direction and an atomization characteristics of a liquid film flow in order to provide the basic data for the development of the twin fluid atomizer. Authors had built the simplified, transparent new devices which can form a uniform thickness of liquid film and an electrical measuring circuit of the liquid film thickness. By introducing the new devices and the measuring circuit, the time variation of a liquid film thickness the mean diameter of the droplets, the droplet size distribution, the degree of the dispersion and the atomization rate of a liquid film are measured experimentally. As the analysis of the study, it can be said the experimental investigation will fairly contribute for further study in this field of study.

  • PDF

Anodization of Aluminium Samples in Boric Acid Solutions by Optical Interferometry Techniques

  • Habib, K.
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.217-221
    • /
    • 2005
  • In the present investigation, holographic interferometry was utilized for the first time to monitor in situ the thickness of the oxide film of aluminium samples during anodization processes in boric acid solutions. The anodization process (oxidation) of the aluminium samples was carried out by the technique of the electrochemical impedance spectroscopy(EIS), in different concentrations of boric acid (0.5-5.0% $H_3BO_3$) at room temperature. In the mean time, the real-time holographic interferometry was used to measure the thickness of anodized (oxide) film of the aluminium samples in solutions. Consequently, holographic interferometry is found very useful for surface finish industries especially for monitoring the early stage of anodization processes of metals, in which the thickness of the anodized film of the aluminium samples can be determined without any physical contact. In addition, measurements of electrochemical values such as the alternating current (A.C) impedance(Z), the double layer capacitance($C_{dl}$), and the polarization resistance(Rp) of anodized films of aluminium samples in boric acid solutions were made by the electrochemical impedance spectroscopy(EIS). Attempts to measure electrochemical values of Z, Cdl, and Rp were not possible by holographic interferometry in boric acid especially in low concentrations of the acid. This is because of the high rate of evolutions of interferometric fringes during the anodization process of the aluminium samples in boric acid, which made measurements of Z, Cdl, and Rp are difficult.

Experimental Analysis and Optimization of Experimental Analysis and Optimization of $CF_4/O_2$ Plasma Etching Process Plasma Etching Process (실험계획법에 의한 $CF_4/O_2$ 플라즈마 에칭공정의 최적화에 관한 연구)

  • Choi, Man-Sung;Kim, Kwang-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.1-5
    • /
    • 2009
  • This investigation is applied Taguchi method and the analysis of variance(ANOVA) to the reactive ion etching(RIE) characteristics of $SiO_2$ film coated on a wafer with Experimental Analysis and Optimization of $CF_4/O_2$ Plasma Etching Process mixture. Plans of experiments via nine experimental runs are based on the orthogonal arrays. A $L_9$ orthogonal array was selected with factors and three levels. The three factors included etching time, RF power, gas mixture ratio. The etching rate of the film were measured as a function of those factors. In this study, the etching thickness mean and uniformity of thickness of the RIE are adopted as the quality targets of the RIE etching process. The partial factorial design of the Taguchi method provides an economical and systematic method for determining the applicable process parameters. The RIE are found to be the most significant factors in both the thickness mean and the uniformity of thickness for a RIE etching process.

  • PDF

Soft computing techniques in prediction Cr(VI) removal efficiency of polymer inclusion membranes

  • Yaqub, Muhammad;EREN, Beytullah;Eyupoglu, Volkan
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.418-425
    • /
    • 2020
  • In this study soft computing techniques including, Artificial Neural Network (ANN) and Adaptive Neuro-Fuzzy Inference System (ANFIS) were investigated for the prediction of Cr(VI) transport efficiency by novel Polymer Inclusion Membranes (PIMs). Transport experiments carried out by varying parameters such as time, film thickness, carrier type, carier rate, plasticizer type, and plasticizer rate. The predictive performance of ANN and ANFIS model was evaluated by using statistical performance criteria such as Root Mean Standard Error (RMSE), Mean Absolute Error (MAE), and Coefficient of Determination (R2). Moreover, Sensitivity Analysis (SA) was carried out to investigate the effect of each input on PIMs Cr(VI) removal efficiency. The proposed ANN model presented reliable and valid results, followed by ANFIS model results. RMSE and MAE values were 0.00556, 0.00163 for ANN and 0.00924, 0.00493 for ANFIS model in the prediction of Cr(VI) removal efficiency on testing data sets. The R2 values were 0.973 and 0.867 on testing data sets by ANN and ANFIS, respectively. Results show that the ANN-based prediction model performed better than ANFIS. SA demonstrated that time; film thickness; carrier type and plasticizer type are major operating parameters having 33.61%, 26.85%, 21.07% and 8.917% contribution, respectively.

EXPERIMENTAL STUDY ON QUANTITATIVE EVALUATION OF FILM-BASED DIGITAL IMAGING SYSTEM (방사선사진용 디지털 영상시스템의 정량적 평가에 관한 실험적 연구)

  • Cho Heang-Hee;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.137-147
    • /
    • 1994
  • A digital imaging system using Machintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quickcapture Frame Grabber Board was evaluated for quantitative analysis of standardized periapical film with aluminum step wedge. The results were as follows: 1. Correlation between Al thickness and gray level was high-positively associated(r²=0.99, p<0.001). 2. Correlation between measured weight of experimental lesion and estimated relative lesion volume by digital subtracted radiography was also high-positively associated (r²=0.98, p<0.001). 3. As exposure time was increased, mean gray level was decreased(p<0.01) and slope of regression line between Al thickness and gray level was also decreased (p<0.01). And when the exposure time was shorter than 0.2 second, the value of r² was relatively low. On the basis of the above results, it is considered that this digital imaging system using a Macintosh Ⅱ ci computer & a high resolution CCD monochrome camera will be useful in evaluating digitized image from standardized periapical film quantitatively.

  • PDF

Polyurethane Semi-occlusive Dressing for Full Thickness Skin Graft Application (전층식피술에 적용한 폴리우레탄 반밀봉드레싱)

  • Lee, Hyuk Gu;Son, Dae Gu;Kim, Hyun Ji;Kim, Jun Hyung;Han, Ki Hwan
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.607-612
    • /
    • 2005
  • A traditional tie-over dressing may be applied to support the take of a skin graft. Although there are many advantage of this method, it has significant disadvantages, including time-consuming application. Furthermore, when the dressing is changed, the gauze becomes hard and can be stuck to the graft, causing damage and pain upon removal. The purpose of our study is to evaluate the effect of semi-occlusive dressing using polyurethane foam and film dressing($Allevyn^{(R)}$, $Opsite^{(R)}$) after full thickness skin graft. The authors treated 45 cases including burn scar contracture(n=38), syndactyly (n=1), absence of nipple-areolar complex(n=4), traumatic skin defect(n=1) and contact burn(n=1) with authors' method and 39 patients including burn scar contracture (n=39) with the tie-over dressing between 2000 and 2004. The patients in polyurethane foam and film dressing group ranged from 1 to 62 years of age (mean age, 15.1 years) and the patients in tie-over dressing group ranged from 2 to 60 years of age(mean age, 21.3 years). The postoperative results were analyzed according to the following measures: (1) the duration of graft-taking, (2) the admission period, (3) complications. Compared with the traditional tie-over dressing, polyurethane foam and film dressing was shown to be more successful in a reduced duration of graft-taking, in which was similar to the former in the rate of graft-taking, a reduced admission period and patient's discomfort. We concluded that semi-occlusive dressing using $Allevyn^{(R)}$ and $Opsite^{(R)}$ was an effective method after full thickness skin graft, which was easy to shape to difficult body locations, such as web spaces, fingers and maintains a moist environment for wound healing and does not stick to the wound.

Preparation of C-plane oriented BaFe12O19 film by electrospray deposition of colloidal precursor particles (정전분무 장치를 이용한 C축 일방향 바륨페라이트(BaFe12O19) 박막형성)

  • Lee, Hye Moon;Kim, Yong Jin
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • New process consisting of electrospray and epitaxial crystal growth processes was applied to the preparation of c-plane oriented barium ferrite ($BaFe_{12}O_{19}$) thin film for high density magnetic recording media. Sodium citrate aided process was proper to preparation of amorphous $BaFe_{12}O_{19}$ nanoparticles with geometric mean diameter of 3 nm and geometric standard deviation of 1.1. The electrospray was applicable to the prepare of amorphous $BaFe_{12}O_{19}$ thin film on a substrate, and the film thickness could be controlled by adjusting the electrospray deposition time. The c-plane oriented $BaFe_{12}O_{19}$ thin film was successfully prepared by 3 step annealing process of the $BaFe_{12}O_{19}$ amorphous film on a sapphire($Al_2O_3$) substrate; annealing at $350^{\circ}C$ for 30 min, annealing at $500^{\circ}C$ for 30 min, and annealing at $700^{\circ}C$ for 60 min.