• 제목/요약/키워드: Time-Amplifier

Search Result 462, Processing Time 0.025 seconds

A Study on the Optimization and the Transient Phenomena of the $Pr^{3+}$ doped Fiber Amplifier ($Pr^{3+}$이 도핑된 광섬유증폭기의 최적화 및 과도현상에 관한 연구)

  • 이재명;지명훈;염진용;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.333-336
    • /
    • 2001
  • The transient response in PDFA(Praseodymium-Doped Fiber Amplifier) is theoretically investigated. The PDFA has the spectral gain band in 1.3${\mu}{\textrm}{m}$. The transient model includes the transient buildup of the population inversion, the pump power, and the signal power and their transient variation along the fiber amplifier. The numerical analysis of transient model can predict the gain saturation, the variation of pump power and the gain as a function of the fiber length. It also shows the gain saturation and recovery effects depending on the pumping rate lead to distortion and saturation in the amplification of optical pulse. The results of numerical analysis, for the case of the Pr ion concentration of 1000ppm and the pump power of 0.5W the gain saturation is obtained 30dB at the length of 5m and the saturation time of upper level is 250 $mutextrm{s}$.

  • PDF

A New Method on the Nonlinear Distortion Analysis in the OFDM Communication System (OFDM 통신 시스템에서 비선형 왜곡분석의 새로운 분석기법)

  • 이동훈;정기호;유흥균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.538-545
    • /
    • 2002
  • In the orthogonal frequency division multiplexing (OFDM) system, the nonlinear distortion in the high power amplifier(HPA) degrades the system performance because of the high peak-to-average power ratio (PAPR). In this paper, a semi-analytical method is newly proposed for the performance evaluation of the nonlinearly distorted OFDM communication system. In the proposed method, at first, the probability density function (pdf) of the PAPR is generated by computer simulation. Then, mean and variance of the non-linear distortion noise process are computed. Next, the overall BER is found by the analytical method. When the equivalent SSPA model is applied in case of the QPSK/16-QAM and AWGN channel, the BER is calculated for the variation of the IBO(input back-off) and PAPR parameter. It is shown that the results by proposed method are very similar to those of the conventional Monte-Carlo method. The computation time can be considerably reduced than the conventional method that depends on the magnitudes of BER and IBO.

A Study on the Reversible SCR Servo Amplifier (정역전이 가능한 SCR 서보증폭기에 관한 연구)

  • Ahn, B. W.;Park, S. K.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.190-198
    • /
    • 1995
  • Many industrial servo amplifiers employ power transister as output device. Thyristor converters are not adopted to drive servo motor, although thyristor is superior to power TR in power rating, noise immunity, price, and size. The reason is, thyristor has no ability of self turn - off. Here in this paper line commutation, in which thyristor is turned off naturally since cathode voltage is higher than anode as time goes by, is employed to turn on thyristor with a delicate sequence. We developed thyristor servo amplifier which does not cause any damage on thyristor because it is designed to prevent triggering the two SCRs in the same arm simultaneously. And it was made clearly how to trigger SCR without any power line shorting and also harmonic analysis is carried out with the aid of FFT analyzer and proved that it can be used even severe reactive load. The designed circuit operated as a good DC amplifier in conventinal servomotor and the results can be use as a position control system application.

  • PDF

Design of a High-Performance Match-Line Sense Amplifier for Selective Match-Line charging Technique (선택적 매치라인 충전기법에 사용되는 고성능 매치라인 감지 증폭기 설계)

  • Ji-Hoon Choi;Jeong-Beom Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.769-776
    • /
    • 2023
  • In this paper, we designed an MLSA(Match-line Sense Amplifier) for low-power CAM(Content Addressable Memory). By using the MLSA and precharge controller, we reduced power consumption during CAM operation by employing a selective match-line charging technique to mitigate power consumption caused by mismatch. Additionally, we further reduced power consumption due to leakage current by terminating precharge early when a mismatch occurs during the search operation. The designed circuit exhibited superior performance compared to the existing circuits, with a reduction of 6.92% and 23.30% in power consumption and propagation delay time, respectively. Moreover, it demonstrated a significant decrease of 29.92% and 52.31% in product-delay-product (PDP) and energy-delay-product (EDP). The proposed circuit was validated using SPECTRE simulation with TSMC 65nm CMOS process.

A Simulation-Based Analog Cell Synthesis with Improved Simulation Efficiency (시뮬레이션 효율을 향상시킨 시뮬레이션 기반의 아날로그 셀 합성)

  • 송병근;곽규달
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.10
    • /
    • pp.8-16
    • /
    • 1999
  • This paper presents a new simulation-based analog cell synthesis approach with improved simulation efficiency For the hierarchical synthesis of analog cells we developed the sub-circuit optimizers such as current mirror and differential input stage. Each sub-circuit optimizer can be used for synthesis of analog cells such as OTA(operational transconductance amplifier), 2-stage OP-AMP and comparator. To reduce the time spending of the simulation-based synthesis we propose 2-stage searching scheme and simulation data reusing scheme. With those schemes the synthesis time spending of OTA was reduced from 301.05sec to 56.52sec by 81.12%. Since our synthesis system doesn't need other additional physical parameters except SPICE parameters, and is independent of the process and its model level, the time spending to port to other process is minimized. We synthesized OTA and 2-stage OP-AMP respectively with our approach to show its usefulness.

  • PDF

A Study on the Electrical Difference for The Limbs and Thoracic Impedance using Real-Time Bio-impedance Measurement System (실시간 생체임피던스 측정 시스템을 이용한 사지와 흉부 임피던스에 대한 전기적인 차이 연구)

  • Cho, Young-Chang;Kim, Min-Soo;Yoon, Jeong-Oh
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.6
    • /
    • pp.9-16
    • /
    • 2013
  • Bio-impedance measurement system(BMS) is non-invasive and easy to implement a measurement method that allows determining the water content of a patient. The measurement conditions, the hardware specifications and the configurations of BMS devices must be well chosen in order to get correct and reproducible results. BMS was then conducted for the limbs and the thoracic using a lock-in amplifier and LabView control system with a frequency range of 1kHz-100kHz. From both the measurement data and the simulation results, we verified that the parameters in the proposed equivalent model and the trend of impedance variation according to the multi-frequency of applied current source are similar to those of human body. We believe that the real-time BMS developed in this study is highly reliable and applicable to the research on the clinical characteristics of the human being's impedance.

Development of the hybrid-type ultrasound speaker (하이브리드형 초음파 스피커 개발)

  • Lee, Hyoung-Sang;Kim, Bok-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.247-253
    • /
    • 2021
  • Directional ultrasonic speakers that are used to hear sound only in a specific area have been continuously researched on various improvements in terms of sound quality and cost compared to general speakers. In this paper, we propose a DSP based hybrid-type ultrasonic speaker that can be heard at the same time as a general speaker in order to compensate for the sound in the low-band range, considering that it is difficult to hear the low-band sound below 500 Hz due to the sensor characteristics of the ultrasonic speaker. In the case of the system that is implemented by simply connecting a general speaker and an ultrasonic speaker, there are issues of high cost and difficulties of control as two amplifiers are used to playback ultrasonic and general sound sources. In addition, sound quality deteriorates due to the difference in playback time between ultrasonic and general sound sources. In order to improve issues of cost, control and sound quality, we developed hybrid-type ultrasonic speaker with a DSP based amplifier that can simultaneously playback by synchronizing the general sound source with the regenerated ultrasonic sound source, in addition to implement the existing CODEC functions such as Dynamic Range Control (DRC) and Equalizer (EQ).

Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

Construction and Performance Characterization of Time-correlated Single Photon Counting System having Picosecond Resolution (피코초 분해능의 시간 상관 단광자 계수 장치 구성 및 동작 특성)

  • 이민영;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • Picosecond time-correlated single photon counting system and time-resolved luminescence spectrometer were constructed, employing a mode-locked picosecond laser, fast electronics, and microchannel plate tube. It has been shown that the instrument response function critically depends on laser pulse shape, timing jitter and walk of the electronics, and characteristics of detector and amplifier. Correcting time dispersion in the optical system, the best instrument response function obtained appears to be 25 ps, which made it possible to measure the luminescence lifetime with less than 10 ps resolution in the picosecond to microsecond range. range.

  • PDF

Development of a High Power SONAR System Measuring Velocity by Using Two Gated Sinusoidal Signals (두 개의 정현 신호를 이용한 속도 측정용 고전력 쏘나 시스템 개발)

  • 장순석;안흥구;이제형
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.1036-1041
    • /
    • 1999
  • This paper aims for the development of the high power sonar system for measuring the velocity of a moving object. The high power sonar system transmits two gated 190 kHz sinusoidal signals with 1.6 [ms] time interval to the moving object. Then the sonar system detects and calculates the changed time delay of the reflected ultrasonic signals in order to derive the velocity of the moving object. The transmission part uses a high power amplifier so that 250 W gated sinusoidal signals can be transmitted to the transmitter. 1M RAM is utilized for transmitting and storing of the ultrasonic signals. The time delay is calculted by the cross-correlation technique between the transmitted signals and the received signals. The measured value from the high power sonar system is compared with directly measured values by photo diodes. The result confirms the adjacency to 0.3% error.

  • PDF