References
- S. Grimnes, "Impedance measurement of individual skin surface electrodes," Med. Biol. Eng. Comput., vol. 21, pp. 750-755, 1983. https://doi.org/10.1007/BF02464038
- OG. Martinsen, S. Grimnes, and J. Karlwen, "Electrical methods for skin moisture assessment," Skin Pharmacol., vol. 8, pp. 237-245, 1995. https://doi.org/10.1159/000211353
- 박성욱, 박종욱, "다층 신경망과 피부색 모델을 이용한 피부영역 검출", 한국산업정보학회 논문지, vol.16, No.2, pp.31-38, 2011년 6월.
- B. E. Lingwood, P. B. Colditz, and L. C. Ward, "Biomedical applications of electrical impedance analysis," Proc. of ISSAP, vol. 1, pp. 367-370, Aug. 1999.
- L. Zhao, L. K. Hung, and Y. T. Zhang, "Electrical properties of normal and scarred skin," Proc. of the IEEE Int. Conf. on Engineering in Medicine and Biology Society, vol. 6, pp. 2917-2920, Nov. 1998.
- A. F. Coston and J. K. -J. Li, "Transdermal drug delivery: An assessment of skin impedance models," Proc. of the IEEE Conf. on Bioengineering, pp. 319-320, March 2003.
- A. H. Lanckermeier, E. T. McAdams, G. P. Moss, and A. D. Wolfson, "On vivo impedance spectroscopy of human skin. Theory and problems in monitoring of passive percutaneous drug delivery," Ann. New York Acad. Sci., vol. 873, pp. 197-213, 1999. https://doi.org/10.1111/j.1749-6632.1999.tb09468.x
- G. Medrano, "Modeling the Influence of Body Position in Bioimpedance Measurements," Proceedings of the 29th Annual International Conference of the IEEE EMBS Lyon, France, 2007.
- L. Beckmann, D. Riesen, S. Leonhardt,"Optimal electrode placement and frequency range selection for the detection of lung water using Bioimpedance Spectroscopy," Proceedings of the 29th Annual International Conference of the IEEE EMBS Lyon, France, 2007.
- S. Grimnes and G. Martinsen, "Bioimpedance", wiley encyclopedia of Biomedical Engineering, John Wiley & Sons Inc 2006.
- S. Grimnes, O. Martinsen, "Bioimpedance and bioelectricity basics", in 1sted. Academic Press, 2000.
- K. S. Cole and R. H. Cole, "Dispersion and absorption in dielectrics. I. Alternating current characteristics," J. Chem. Phys., vol. 9, pp. 110-122, 1941.
- R. Buendia, P. Bogonez-Franco, L. Nescolarde, R. Seoane, "Influence of electrode mismatch on Cole parameter estimation from Total Right Side Electrical Bioimpedance Spectroscopy measurements," Med. Eng. & Phys. vol. 34, pp. 1024-1028, 2012. https://doi.org/10.1016/j.medengphy.2012.05.011
- R. Buendia, R. Gil-Pita, F. Seoane,"Cole parameter estimation from the modulus of the electrical bioimpedance for assessment fo body composition. A full spectroscopy approach," J electr. Bioimp. vol. 2, pp. 72-78, 2011.
Cited by
- Characteristics of Bio-impedance for Implantable Electrode Design in Human Skin vol.19, pp.4, 2014, https://doi.org/10.9723/jksiis.2014.19.4.009
- Analysis of Bioimpedance Change and the Characteristics of Blood Pressure according to Posture vol.19, pp.5, 2014, https://doi.org/10.9723/jksiis.2014.19.5.025
- Analysis of affected and non-affected sides of stroke hemiparalysis patients and correlations between rehabilitation therapy assessments using the bioelectrical impedance analysis method vol.28, pp.12, 2016, https://doi.org/10.1589/jpts.28.3306
- Predicting body compositions of live finishing pigs based on bioelectrical impedance analysis vol.63, pp.2, 2013, https://doi.org/10.5187/jast.2021.e31