• Title/Summary/Keyword: Tilt System

Search Result 688, Processing Time 0.029 seconds

A Comparative Study of Characters of Muscle Activity in Lower Limb and Gait Pattern on Type of Heel Rockers (신발 아웃솔의 굴곡 형태에 따른 하지근육활동의 특성과 보행 패턴의 비교연구)

  • An, Song-Y;Kim, Sang-Bum;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.111-119
    • /
    • 2007
  • The purpose of this study was to investigate muscle activity and gait pattern in lower limb depending on the outsole of heel rockers. Fifteen healthy men volunteered for this experiment. Each subject performed totally three trails with two pairs of different heel rocker shoes and a pair of normal running shoes at speed of 1.33m/s for 1 minute during walking on a treadmill. Kinematic data gathered in 100Hz was recorded and analyzed by using the 3D motion capture system to measure the trunk tilt and joint angle of the right lower limb. And the lower extremity muscle activities were simultaneously recorded in 1000Hz and assessed by using EMG. The statistical analysis was the one-way ANOVA with the repeated measures to compare among the three kinds of shoes. The level of statistical significance for all tests was 0.05. Joint angle of lower limb was showed statistically significant different in MST(hip joint), LHS(ankle joint), and RTO(knee and ankle joint). Muscle activity of rectus femoris and biceps femoris was statistically increased in both heel rocker shoes during gait cycle on treadmill. The maximum peak time of tibialis anterior in the negative heel rocker showed the delay of approximately 23.8%time than normal shoes. Gait pattern variability of the negative heel rocker was increased in the first half of the stance phase and the variability of the positive heel rocker was increased in the terminal stance phase. In Conclusion, stability was decreased in between joints of lower limb on positive heel rocker than negative heel rocker. This study found that there were different joint angle, muscle activity, gait pattern and coordinate system of the lower limb in each kind of shoes. These unstability affected the lower extremity and the whole body. A further study has to be continued with study of rehabilitation and exercise for a long-term.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

m-shaper: A Sketch Drawing System for Musical Shape Generation (m-shaper: 음악적 형태 생성을 위한 스케치 드로잉 시스템)

  • Kwon, Doo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1381-1387
    • /
    • 2015
  • This paper proposes a sketch drawing system called m-shaper for musical shape generation. Through simple sketch drawing, users can generate musical shape configuration which can be played by a computer. One key ingredient of the process is a unique concept for the interactive musical shape generation that combines shape and sound based on the designers' manual inputs. m-shaper captures the numerical values of drawing characteristics and determines how the musical notes and shapes can be generated. Using a tablet, four sketch movements are captured such as pressure, tilt, rotation and speed. Each point of a shape corresponds to a certain musical note that represents a type of instrument, duration, pitch, and octave. The current m-shaper has been developed as a computational tool for supporting the schematic design process. Designers in m-shaper draw geometric sketches with a musical inspiration and explore possible conceptual forms. They also can control the parameters for results and transform their sketch drawing.

Adult Patients with Congenital Muscular Torticollis Treated with Bipolar Release : Report of 31 Cases

  • Lee, Gun Sang;Lee, Myung Ki;Kim, Woo Jae;Kim, Ho Sang;Kim, Jeong Ho;Kim, Yun-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Objective : We assessed the surgical results of bipolar release in 31 adult patients with uncorrected congenital muscular torticollis (CMT) and more than 12 months of follow-up. Methods : Thirty-one patients underwent a bipolar release of the sternocleidomastoid muscle (SCM) and were retrospectively analyzed. The mean follow-up period was 14.9 months (range, 12-30). The mean age at time of surgery was 30.3 years (range, 20-54). Patients were evaluated with a modified Lee's scoring system, cervicomandibular angle (CMA) measurement, and a global satisfaction rating scale using patient self-reporting. Results : The modified Lee's scoring system indicated excellent results in 4 (12.9%) patients, good in 18 (58.1%), and fair in 9 (29.0%) at the last follow-up after surgery. The improvements in neck movement and head tilt were statistically significant (p<0.05). The preoperative mean CMA was $15.4^{\circ}$ (range, 5.4-29.0), which was reduced to a mean of CMA of $6.3^{\circ}$ (range, 0-25) after surgery (p<0.05). The global satisfaction rating scale was 93.7% (range, 90-100). A transient sensory deficit on the ipsilateral lower ear lobe was noted in three cases. No significant permanent complications occurred. Conclusion : Bipolar release of the SCM is a safe and reliable technique for the treatment of CMT in adults.

A Study on Rotational Alignment Algorithm for Improving Character Recognition (문자 인식 향상을 위한 회전 정렬 알고리즘에 관한 연구)

  • Jin, Go-Whan
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.79-84
    • /
    • 2019
  • Video image based technology is being used in various fields with continuous development. The demand for vision system technology that analyzes and discriminates image objects acquired through cameras is rapidly increasing. Image processing is one of the core technologies of vision systems, and is used for defect inspection in the semiconductor manufacturing field, object recognition inspection such as the number of tire surfaces and symbols. In addition, research into license plate recognition is ongoing, and it is necessary to recognize objects quickly and accurately. In this paper, propose a recognition model through the rotational alignment of objects after checking the angle value of the tilt of the object in the input video image for the recognition of inclined objects such as numbers or symbols marked on the surface. The proposed model can perform object recognition of the rotationally sorted image after extracting the object region and calculating the angle of the object based on the contour algorithm. The proposed model extracts the object region based on the contour algorithm, calculates the angle of the object, and then performs object recognition on the rotationally aligned image. In future research, it is necessary to study template matching through machine learning.

Design Optimization of QTP-UAV Prop-Rotor Blade Using ModelCenter (ModelCenter를 이용한 QTP-UAV 프롭로터 블레이드 형상 최적설계)

  • Kang, Hee Jung
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.4
    • /
    • pp.36-43
    • /
    • 2017
  • Blade design optimization of QTP-UAV prop-rotor was conducted using ModelCenter(R). Performance efficiency of the blade in hover and forward flight were adopted as the multi-objective function. Required power and pitch link force applied to constraint in each flight mode and limited lower than the value of the baseline blade. Design variables of root chord length of the blade, taper ratio, twist slope, twist angle at 0.5R of the blade, anhedral angle, parabolic coefficient of a tip shape and location of airfoil were used to generate the blade planform. CAMRAD-II, the comprehensive analysis program of rotorcraft, was used for performance analysis of prop-rotor blade in design process. Performance of the optimized blade improved 1.6% of figure of merit in hover and 13.6% of propulsive efficiency in forward flight. Pitch link force also reduced approximately 30% less than that of the baseline blade.

Study of the Reflector Shape of a Test Lamp for a Flame Detector with Little Influence of Error in Optical-system Fabrication (광학계 제작 시 오차 영향이 적은 불꽃감지기용 테스트램프 반사경 형상에 관한 연구)

  • Park, Hye-Jin;Kang, Dong-Hwa;Kong, Mi-Seon;Kim, Eun-Ji;Lee, Ye-Eun;Jo, Ye-Ji;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.233-240
    • /
    • 2018
  • In this paper, a design method to reduce fabrication errors in reflector shape of a test lamp for a flame detector is carried out. Although the test lamp should be operated in parallel with a high-intensity light, it is difficult to fix the small reflector that controls the central light during fabrication. To solve these problems, a small spherical reflector is designed to minimize the performance degradation for a light loss factor of less than 5%, even during tilt and decenter, and a spherical shape is proposed for a small reflector with little effect on the error when designing the optical system.

Implementation of Omni-directional Image Viewer Program for Effective Monitoring (효과적인 감시를 위한 전방위 영상 기반 뷰어 프로그램 구현)

  • Jeon, So-Yeon;Kim, Cheong-Hwa;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.939-946
    • /
    • 2018
  • In this paper, we implement a viewer program that can monitor effectively using omni-directional images. The program consists of four modes: Normal mode, ROI(Region of Interest) mode, Tracking mode, and Auto-rotation mode, and the results for each mode is displayed simultaneously. In the normal mode, the wide angle image is rendered as a spherical image to enable pan, tilt, and zoom. In ROI mode, the area is displayed expanded by selecting an area. And, in Auto-rotation mode, it is possible to track the object by mapping the position of the object with the rotation angle of the spherical image to prevent the object from deviating from the spherical image in Tracking mode. Parallel programming for processing of multiple modes is performed to improve the processing speed. This has the advantage that various angles can be seen compared with surveillance system having a limited angle of view.

Development of Multi-channel Fiber Laser and Beam Alignment Method (다채널 광섬유 레이저 및 다중 빔 정렬 기술 개발)

  • Kim, Youngchan;Ryu, Daegeon;Noh, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2022
  • We have developed a multi-channel fiber laser for tiled laser beam combining and a laser output array system for multi-beam alignment. The fiber laser is a master oscillator power amplifier configuration that has a common seed, a preamplifier, and a 7-channel amplifier. The output power of each channel is more than 10 W. The laser output array system is a packed cylindrical configuration for a high fill-factor, and it has capabilities for collimation and tilt control with built-in PZT. Multi-beam alignment to a target is successfully implemented using PZT controlled with a stochastic parallel gradient descent (SPGD) algorithm.

Optomechanical Design and Structure Analysis of Prototype Siderostat for Testing Local Volume Mapper Telescope Control System

  • Lee, Sunwoo;Han, Jimin;Ahn, Hojae;Kim, Changgon;Yang, Mingyeong;Ji, Tae-geun;Lee, Sumin;Kim, Taeeun;Pak, Soojong;Konidaris, Nicholas P.;Drory, Niv;Froning, Cynthia S.;Hebert, Anthony;Bilgi, Pavan;Blanc, Guillermo A.;Lanz, Alicia E.;Hull, Charles L;Kollmeier, Juna A.;Ramirez, Solange;Wachter, Stefanie;Kreckel, Kathryn;Pellegrini, Eric;Almeida, Andr'es;Case, Scott;Zhelem, Ross;Feger, Tobias;Lawrence, Jon;Lesser, Michael;Herbst, Tom;Sanchez-Gallego, Jose;Bershady, Matthew A;Chattopadhyay, Sabyasachi;Hauser, Andrew;Smith, Michael;Wolf, Marsha J;Yan, Renbin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.4-39
    • /
    • 2021
  • The Local Volume Mapper (LVM), for the Sloan Digital Sky Survey V, consists of four 16 cm telescopes with three fiber spectrographs in the Las Campanas Observatory in Chile. With the fixed telescopes on optical tables, the Alt-Alt mounted siderostats point and guide targets during spectrograph exposures. We are developing the integrated LVM instrument control software. Considering international travel restrictions caused by the COVID-19 pandemic in 2021, we decided to make a simplified version of siderostat to test the LVM telescope control system in Korea. The prototype siderostat consists of two aluminum flat mirrors, optomechanical housing structures made by aluminum profiles, and the Planewave L-350 mount. We designed the optical mirrors and the optomechanical structure of the siderostat. From structural analysis at various pointing cases, we estimated the tilt misalignments of mirrors within 4 arcsec, which would affect the telescope pointing errors.

  • PDF