• Title/Summary/Keyword: Threshold stimulus

Search Result 68, Processing Time 0.024 seconds

A basic study for the behaviour control of sevenband grouper, Epinephelus septem fasciatus, to underwater low frequency sound I. The Auditory thresholds of sevenband grouper (수중 저주파에 의한 능성어 (Epinephelus septem fasciatus)의 행동제어에 관한 기초적 연구 I. 능성어의 청각문턱치)

  • 양용수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.4
    • /
    • pp.391-396
    • /
    • 1999
  • It is well known that fish hear a wide frequency range of sound using both laterial line and inner ear, and the sound is probably the most effective channel for long-range communication underwater than any other stimulus.The auditory threshold of svenband grouper, Epinephelus septem fasciatus was determined by conditioning method using a sound coupled with electric shock in a tank. The audio-signals and electric shock used in the experiment were pure tones of 100 to 1000Hz and DC 6n.The response of fish to the sound was observed by ECG intervals from precordial leads method (V1·V2 method). The auditory threshold curve for sevenband grouper was V-shaped, with most sensitive threshold at 350Hz in the range of 100~1000Hz. The Sevenband grouper were more sensitive to sounds of 200~400Hz than to adjacent frequencies.

  • PDF

A Multi-photodiode Array-based Retinal Implant IC with On/off Stimulation Strategy to Improve Spatial Resolution

  • Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.

Information Processing Characteristic for Changes in Impulse Patterns in the Neuron Pool (임펄스 패턴변화에 따른 집단신경세포의 정보처리 특성)

  • Kim, Yong-Man;Lee, Kyung-Joong;Lee, Myung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.127-140
    • /
    • 1981
  • This paper describes the mechanism of information processing in the nervous system through neuron pool model which is consisted of six single neural models. In the neuron pool model, summation characteristic of stimulus satisfies those of real nervous system and output impulse rate increases linearly to the input stimulus. Occlusion phenomena of the neuron pool model is approached to those of real nervous system and also if the threshold potential within sutlirninal fringe is increased, facilitation phenomena appreared. Therefore, the results of this study suggest that we can construct large neuron pool with many single neural models and verify the mechanism of information processing in the wide part of nervous system.

  • PDF

Fabrication and Evaluation of Tactile Stimulator Using Stacked PZT (적층형 액추에이터를 이용한 촉각자극기의 제작 및 평가 PZT)

  • 윤명종;권대규;김남균;유기호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.450-453
    • /
    • 2004
  • A tactile stimulator array using stacked PZT is fabricated and evaluated in this paper. The purpose of this research is the development of a tactile stimulator to represent the obstacle information for the visually disabled. As a first step of this research, we investigate the physiological characteristics of tactile stimuli and design a tactile stimulator based on the investigated results. Also we evaluated a fabricated tactile stimulator. The prototype of tactile stimulator which has 2$\times$2 tactor elements with 3mm spacing is fabricated using stacked PZT actuator. In order to evaluate the characteristics of this tactile stimulator, physiological experiments are carried out. In the experiment, the threshold of tactile stimulus intensity within a frequency range of 5-500Hz at various stimulus amplitudes are investigated. According to the obtained experimental result, the input signal of tactile stimulator for the effective transfer of obstacle information is determined. Also physiological experiments of multi-stimuli recognition such as shift and rotation are carried out

  • PDF

An Auto-range Fast Bilateral Filter Using Adaptive Standard Deviation for HDR Image Rendering (HDR 영상 렌더링을 위한 적응적 표준 편차를 이용한 자동 레인지 고속 양방향 필터)

  • Bae, Tae-Wuk;Lee, Sung-Hak;Kim, Byoung-Ik;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4C
    • /
    • pp.350-357
    • /
    • 2010
  • In this paper, we present an auto-range fast bilateral filter (FBF) for high-dynamic-range (HDR) images, which increases computation speed by using adaptive standard deviations for range filter (RF) of FBF in iCAM06. Many images that cover the entire dynamic range of the scene with different exposure times are fused into one High Dynamic Range (HDR) image. The representative algorithm for HDR image rendering is iCAM06, which is based on the iCAM framework, such as the local white point adaptation, chromatic adaptation, and the image processing transform (IPT) uniform color space. FBF in iCAM06 uses constant standard deviation in RF. So, it causes unnecessary FBF computation in high stimulus range with broad and low distribution. To solve this problem, the low stimulus image and high stimulus image of CIE tri-stimulus values (XYZ) divided by the threshold are respectively processed by adaptive standard deviation based on its histogram distribution. Experiment results show that the proposed method reduces computation time than the previous FBF.

Study on Relation of Effects of Electro-acupuncture with Sex, Age, and Weight in Rats (흰쥐의 성별, 체중 및 주령에 따른 족삼리(足三里) 전침자극의 면화가 소장수송능(小腸輸送能)에 미치는 영향)

  • Hwang, Tae-Joon;Yu, Yun-Cho;Oh, Inn-Kun;Oh, Eun-Ki;Kim, Myung-Dong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.3
    • /
    • pp.748-754
    • /
    • 2007
  • Electroacupuncture is the combined treatment of mechanical and electric stimuli on the needle head, on which electricity runs after acupuncturing at the acupuncture points. It is reported that its treatment effect depends on the parameter of stimulus, which is wave of stimulus, frequency, voltage, and duration of electric current. To get the effective treatment, stimulus intensity over threshold is needed. We planned to experiment whether acupuncture effect is affected by sex, age, and weight. After we conducted electric stimulus at Zusanli(ST 36) which is known to increase small intestinal motility in normal rats, we observed the effects and got the following results. Though the increased effects of small intestinal motility of electro-acupuncture at Zusanli(ST 36) did not show the difference of sex, this effect was observed to have a tendency to decrease according to weight increase without distinction of sex. But the effect of electro-acupuncture shown in 4, 5, 7 weeks old without distinction of sex was observed to have a tendency to decrease with the growing of weeks-old in the male rat group. And the significant change without specific tendency was observed in the 4, 5 weeks old female rat group. This result suggested that sex, weight, and age should be considered to get the efficient electro-acupuncture. The more experimental study should be advanced to investigate the correlation between the factors that can affect the acupuncture treatment, and, afterward, the interconnection into the clinical use.

A Simulation Method for Bone Growth Using Design Space Optimization (설계공간 최적화를 이용한 뼈 성장 모사)

  • Jang In-Gwun;Kwak Byung-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.722-727
    • /
    • 2006
  • Bone fracture healing is one of the important topics in biomechanics, demanding computation simulations due to the difficulty of obtaining experimental or clinical results. In this study, we adopt the design space optimization method which was established by the authors as a tool for the simulation of bone growth using its evolutionary characteristics. As the mechanical stimulus, strain energy density is used. We assume that bone tissues over a threshold strain energy density will be differentiated and bone tissues below another threshold will be resorbed. Under compression and torsion as loadings, the filling process of the defect is well illustrated following the given mechanical criterion. It is shown that the design space optimization is an excellent tool for simulating the evolutionary process of bone growth, which has not been possible otherwise.

Measurement of the pain responses induced by electric pulp test (전기 치수 자극에 의해 유발된 동통 반응의 측정)

  • Ahn, Seon-Hui;Nam, Ki-Chang;Kim, Soo-Chan;Kim, Jae-Sung;Lee, Seung-Jong;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.727-730
    • /
    • 2003
  • Electric pulp test is a method to examine the vitality of dental pulp using the electrical stimulation. During the pulp test, the current stimulates intradental nerve, and makes patients painful. Some studies were accomplished to measure the responses of subjects by stimulating over the sensory threshold. In this study, we examined the time delay between pain feeling and stimulation stop in clinical situation. And we measured the activated responses(EMG in anterior belly of digastric muscle, voice, and finger span). As a result, it was verified that the minimum and maximum delay was EMG and voice, respectively. By reducing the excessive stimulus time, the unnecessary pain can be minimized using EMG that has the minimum delay.

  • PDF

Quantitative vibratory sense measurement systems of a diabetic neuropathy (당뇨병성 신경병증의 정량적 진동 감각 측정 시스템)

  • Ryu, Bong-Jo;Kim, Youngshik;Koo, Kyung-Wan
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.615-620
    • /
    • 2018
  • Evaluation of clinical usefulness of current perception threshold test and vibration sense perception threshold test in diagnosing the diabetic poly-neuropathy patients is one of the diagnosis methods for diabetic poly-neuropathy. Up to the present, some diagnostic methods were used for diabetic poly neuropathy patients. For example, there are neuropathy impairment score test of lower limbs, nerve conduction test, cooling detection threshold test, heat-pain threshold test and so on. However, most of the above tests require very expensive cost and take a lot of time in test. In this paper, a new apparatus estimating vibration sense ability is introduced. For this purpose, the VCM(voice coil motor) stimulating patient's peripheral nerve and current amplifier were manufactured. Also, softwares sensing and driving the vibration detection threshold test in order to measure the quantitative vibration sensory levels in diabetic poly-neuropathy patients were developed.

Normal data on axonal excitability in Koreans

  • Lee, Ju Young;Yu, Jin Hyeok;Pyun, So Young;Ryu, Sanghyo;Bae, Jong Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2017
  • Background: Automated nerve excitability testing is used to assess various peripheral neuropathies and motor neuron diseases. Comparing these excitability parameters with normal data provides information regarding the axonal excitability properties and ion biophysics in diseased axons. This study measured and compared normal values of axonal excitability parameters in both the distal motor and sensory axons of normal Koreans. Methods: The axonal excitability properties of 50 distal median motor axons and 30 distal median sensory axons were measured. An automated nerve excitability test was performed using the QTRACW threshold-tracking software (Institute of Neurology, University College London, London, UK) with the TRONDF multiple excitability recording protocol. Each parameter of stimulus-response curves, threshold electrotonus, current-voltage relationship, and recovery cycle was measured and calculated. Results: Our Korean normal data on axonal excitability showed ranges of values and characteristics similar to previous reports from other countries. We also reaffirmed that there exist characteristic differences in excitability properties between motor and sensory axons: compared to motor axons, sensory axons showed an increased strength-duration time constant, more prominent changes in threshold to hyperpolarizing threshold electrotonus (TE) and less prominent changes in threshold to depolarizing TE, and more prominent refractoriness and less prominent subexcitability and superexcitability. Conclusions: We report normal data on axonal excitability in Koreans. These data can be used to compare various pathological conditions in peripheral nerve axons such as peripheral neuropathies and motor neuron disease.