• Title/Summary/Keyword: Threshold of 0.5%

Search Result 1,181, Processing Time 0.028 seconds

Effect of Environmental Factors on the Determination of the Ecotoxicological Threshold Concentration of Cu in Soil Pore Water through Biotic Ligand Model and Species Sensitivity Distribution (Biotic ligand model과 종 민감도 분포를 이용한 토양 공극수 내 Cu의 생태독성학적 허용농도 결정에 미치는 환경인자의 영향)

  • Yu, Gihyeon;An, Jinsung;Jeong, Buyun;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.1
    • /
    • pp.49-58
    • /
    • 2017
  • Biotic ligand model (BLM) and species sensitivity distribution (SSD) were used to determine the site-specific Cu threshold concentration (5% hazardous concentration; HC5) in soil pore water. Model parameters for Cu-BLM were collected for six plants, one collembola, and two earthworms from published literatures. Half maximal effective concentration ($EC_{50}\{Cu^{2+}\}$), expressed as $Cu^{2+}$ activity, was calculated based on activities of major cations and the collected Cu-BLM parameters. The $EC_{50}\{Cu^{2+}\}$ varied from 2 nM to $251{\mu}M$ according to the variation in environmental factors of soil pore water (pH, major cation/anion concentrations) and the type of species. Hazardous activity for 5% (HA5) and HC5 calculated from SSD varied from 0.076 to $0.4{\mu}g/L$ and 0.4 to $83.4{\mu}g/L$, respectively. HA5 and HC5 significantly decreased with the increase in pH in the region with pH less than 7 due to the decrease in competition with $H^+$ and $Cu^{2+}$. In the region with pH more than 7, HC5 increased with the increase in pH due to the formation of complexes of Cu with inorganic ligands. In the presence of dissolved organic carbon (DOC), Cu and DOC form a complex, which decreases $Cu^{2+}$ activity in soil pore water, resulting in up to 292-fold increase in HC5 from 0.48 to $140{\mu}g/L$.

The Optimal Method to Determine Damage Threshold of Rock using Hwangdeung Granite (황등화강암을 이용한 암석의 손상기준 결정방법 연구)

  • Jang, Bo-An;Ji, Hoon;Jang, Hyun-Shic
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.89-100
    • /
    • 2010
  • Although various methods for determination of damage threshold in rock have been suggested, clear damage thresholds were determined by some methods, but different thresholds were measured by other methods. We determined the damage thresholds in Hangdeung granite using all the methods suggested, and investigated the best methods, applicability and errors of each method. The crack initiation threshold and the crack damage threshold which are important in investigation of characteristics of crack development and failure were verified by field strength ratio method and long-term constant load test. The crack closure stress and the crack initiation stress were 57.5 MPa and 77.6 MPa, and the most exact values were yielded by crack volumetric strain. The secondary crack initiation stress was 90.6 MPa and AE event count and AE event count rate were the effective methods. The volumetric stiffness, AE event count and AE event count rate were the most effective methods for determination of crack coalescence threshold and crack coalescence stress was 110.3 MPa. The crack damage stress was 127.5 MPa and was measured correctly by volumetric stiffness and AE event count rate. The ratio between crack initiation stress and uniaxial compressive strength was 0.47 which was very similar with the FSR value of 0.46. The ratio between crack damage stress and uniaxial compressive strength was almost the same as the ratio between long-term strength and uniaxial compressive strength, indicating that the crack initiation stress and the crack damage stress measured were correct.

Detecting Vehicles That Are Illegally Driving on Road Shoulders Using Faster R-CNN (Faster R-CNN을 이용한 갓길 차로 위반 차량 검출)

  • Go, MyungJin;Park, Minju;Yeo, Jiho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.1
    • /
    • pp.105-122
    • /
    • 2022
  • According to the statistics about the fatal crashes that have occurred on the expressways for the last 5 years, those who died on the shoulders of the road has been as 3 times high as the others who died on the expressways. It suggests that the crashes on the shoulders of the road should be fatal, and that it would be important to prevent the traffic crashes by cracking down on the vehicles intruding the shoulders of the road. Therefore, this study proposed a method to detect a vehicle that violates the shoulder lane by using the Faster R-CNN. The vehicle was detected based on the Faster R-CNN, and an additional reading module was configured to determine whether there was a shoulder violation. For experiments and evaluations, GTAV, a simulation game that can reproduce situations similar to the real world, was used. 1,800 images of training data and 800 evaluation data were processed and generated, and the performance according to the change of the threshold value was measured in ZFNet and VGG16. As a result, the detection rate of ZFNet was 99.2% based on Threshold 0.8 and VGG16 93.9% based on Threshold 0.7, and the average detection speed for each model was 0.0468 seconds for ZFNet and 0.16 seconds for VGG16, so the detection rate of ZFNet was about 7% higher. The speed was also confirmed to be about 3.4 times faster. These results show that even in a relatively uncomplicated network, it is possible to detect a vehicle that violates the shoulder lane at a high speed without pre-processing the input image. It suggests that this algorithm can be used to detect violations of designated lanes if sufficient training datasets based on actual video data are obtained.

Hearing Threshold Shift Level of Weavers on Wearing the Ear Plugs (이전장용여부(耳栓裝用與否)에 따른 난청도(難聽度)의 추이(推移))

  • Kim, Yeong-Hwan;Lee, Jong-Young;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.57-63
    • /
    • 1984
  • To assess the hearing conservation by the hearing protection devices in the field, 1,237 healthy female weavers of 16 to 24 year old were surveyed from April 1982 to January 1983. By reviewing the charts, their working durations, hearing threshold shift levels and whether wearing the ear plugs or not were checked. The hearing threshold levels were measured at 4,000Hz by audiometry AA-30A, RION Japan. They were divided into two groups: an experimental group with ear plug and the control group without it. The threshold shift level above 40dB in controls was 44.6% in left and 40.9% in right ear and that in experimental group 8.0% in left and 6.6% in right ear. The distribution of threshold shift levels between control and experimental group was significantly different in both ears, but that between left and right ear not significantly different in both groups. The longer the working durations were, the more the proportion of high threshold shift levels was and the larger the differences in the proportion of above 40dB between both groups were.

  • PDF

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels (터널 순응휘도와 경계부 휘도의 관계 연구)

  • Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.85-99
    • /
    • 2014
  • PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.

The analysis of leakage current of InGaAsP/InP PBH-LD fabricated by LPE (LPE 방법으로 제작된 InGaAsP/InP PBH-LD의 누설전류해석)

  • 최미숙;김정호;홍창희
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.481-485
    • /
    • 2002
  • In this study, we fabricated the PBH-LD by meltback method using the LPE. The PBH-LDs are analyzed the leakage current that flows through leakage current path like the p-n diode and p-n-p-n current blocking layer. We observed the variation of threshold current with the leakage width $W_{ι}$. As a consequence, we confirmed that the threshold current became low in the decrease of the leakage width and in the increase of the ratio of specific resistivity of leakage region to active region. We also compared between the calculated threshold current in the absence of leakage region and the measured threshold current in the device. As a result, the ratio of specific resistivity was about 0.5 in the measured LDs, which have the width of a active layer of 1.4${\mu}{\textrm}{m}$ and leakage width of 0.6${\mu}{\textrm}{m}$.

  • PDF

Effects of Ga Composition Ratio and Annealing Temperature on the Electrical Characteristics of Solution-processed IGZO Thin-film Transistors

  • Lee, Dong-Hee;Park, Sung-Min;Kim, Dae-Kuk;Lim, Yoo-Sung;Yi, Moonsuk
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.163-168
    • /
    • 2014
  • Bottom gate thin-film transistors were fabricated using solution processed IGZO channel layers with various gallium composition ratios that were annealed on a hot plate. Increasing the gallium ratio from 0.1 to 0.6 induced a threshold voltage shift in the electrical characteristics, whereas the molar ratio of In:Zn was fixed to 1:1. Among the devices, the IGZO-TFTs with gallium ratios of 0.4 and 0.5 exhibited suitable switching characteristics with low off-current and low SS values. The IGZO-TFTs prepared from IGZO films with a gallium ratio of 0.4 showed a mobility, on/off current ratio, threshold voltage, and subthreshold swing value of $0.1135cm^2/V{\cdot}s$, ${\sim}10^6$, 0.8 V, and 0.69 V/dec, respectively. IGZO-TFTs annealed at $300^{\circ}C$, $350^{\circ}C$, and $400^{\circ}C$ were also fabricated. Annealing at lower temperatures induced a positive shift in the threshold voltage and produced inferior electrical properties.

Orofacial Thermal Quantitative Sensory Testing (QST): A Study of Healthy Korean Women and Sex Difference

  • Ahn, Sung-Woo;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.3
    • /
    • pp.96-101
    • /
    • 2015
  • Purpose: Thermal sensory test as an essential part of quantitative sensory testing (QST) has been recognized as a useful tool in the evaluation of the trigeminal nerve function. Normative data in the orofacial region have been reported but the data on differences in the test site, sex and ethnicity are still insufficient. Thus, this study aimed to investigate the normal range of orofacial thermal QST data in the healthy Korean women, and assess sex difference of thermal perception in the orofacial regions. Methods: Thermal QST was conducted on 20 healthy women participants (mean age, 26.4 years; range, 21 to 34 years). The thermal thresholds (cold detection threshold, CDT; warm detection threshold, WDT; cold pain threshold, CPT; and heat pain threshold, HPT) were measured bilaterally at the 5 trigeminal sites (the forehead, cheek, mentum, lower lip and tongue tip). The normative thermal thresholds of women in the orofacial region were evaluated using one-way ANOVA and compared with the previously reported data from age- and site-matched 30 healthy men (mean age, 26.1 years; range, 23 to 32 years) using two-way ANOVA. One experienced operator performed the tests of both sexes and all tests were done in the same condition except the time variability. Results: Women showed significant site differences for the CDT (p<0.001), WDT (p<0.001), and HPT (p=0.047) in the orofacial region. The CDT (p<0.001) and the CPT (p=0.007) presented significant sex difference unlike the WDT and the HPT. Conclusions: The thermal sensory evaluation in the orofacial region should be considered in the context of site and sex and the normative data in this study could be useful for assessment of the sensory abnormalities in the clinical setting.

The changes of acute toxicity of pesticides depending on the exposure time to killifish, Oryzias latipes. (농약의 노출시간에 따른 급성어독성의 변화)

  • Shin, Chun-Chul;Lee, Sung-Kyu;Roh, Jung-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.7 no.2
    • /
    • pp.124-129
    • /
    • 1988
  • Prolonged aquatic toxicity tests (7-days) of six pesticides to the freshwater fish Oryzias latipes were performed to confirm the adequacy of the exposure times, 48-hr or 96-hr, which has been required by the protocols for the aquatic acute toxicity test. The toxicity curves were plotted for each chemical, and the significance of the difference between lethal threshold concentrations and 48-hr or 96-hr LC50's was analysed statistically. The lethal threshold concentrations of butachlor, fenobucarb, and chlorothalonil were clearly defined on the 5th day, 2nd day, and 2nd day at 0.53mg/1, 10.3mg/l, and 0.085mg/1, respectively. But the toxicity curves of alachlor, diazinon, and iprobenfos continued with no threshold for 7 days. Four out of six test pesticides failed to show the threshold concentration during the 96-hr exposure time. Therefore, the results of the acute toxicity test using 48-hr or 96-hr exposure time would not describe the ideal toxicity of pesticides. It is recommended that the prolonged exposure should be continued long enough to define the threshold adequately.

  • PDF

The Effects of Mechanical Stimulation using Graston on Changing Trigger Point Pressure Pain Threshold and Muscle Tone of the Same Spinal Segment in Neck Disk Patient (목 디스크 환자에게 그라스톤을 이용한 기계적 자극 시 동일 척수 분절의 통증 유발점 압통 역치 및 근 긴장도에 미치는 영향)

  • Kim, Do-Hyung;Lee, Byoung-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.198-205
    • /
    • 2019
  • The purpose of this study was to identify whether cutaneous sensory (CS) changes induced by mechanical intervention(MI) increases the trigger point threshold and muscle tone of the same spinal segment to neck disc patients. Thirty persons with Neck disc patients were recruited in this experiment. The subjects consisted of 10 men and 20 women. The mechanical stimulus group induced CS changes for 5 minutes using the Graston instrument and the control group received no action. The CS changes were estimated by using the Von Frey Filament, PPT changes were measured by using the pressure threshold meter and msucle tone changes were measured by using Myotone pro. CS threshold increased significantly when MI was applied (p<0.05). On the same spinal segment, increases in the right infraspinatus PPT and muscle tone was observed (p<0.05) and decreases in the right trapezius PPT was observed(p<0.05). However, the PPT and muscle tone changes in other muscles were not significantly different. Furthermore, the control group CS, PPT and muscle tone were not significantly different. As a result, CS changes induced by MI make to change PPT and muscle tone on the same spinal segment. Therefore, application of MI to the same spinal segment may be of clinical significance as a new rehabilitation method for increasing pain threshold, muscle tone and pain control in neck disc patients.