Browse > Article
http://dx.doi.org/10.7855/IJHE.2014.16.3.085

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels  

Cho, Won Bum (Highway & Transportation Research Division, SOC Research Institute, Korea Institute of Construction Technology)
Jeong, Jun Hwa (Highway & Transportation Research Division, SOC Research Institute, Korea Institute of Construction Technology)
Publication Information
International Journal of Highway Engineering / v.16, no.3, 2014 , pp. 85-99 More about this Journal
Abstract
PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.
Keywords
vehicular traffic tunnel; threshold zone luminance; adaptation luminance; luminance ratio;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Narisada K. ; Yoshikawa K. ; Tunnel entrance lighting?effect of fixation point and other factors on the determination of requirements, Lighting Research & Technology Vol.6 No.1, pp.9- 19, 1974.   DOI
2 Korea Institute of Construction Technology, A Study for amendment road lighting guideline, 2011.
3 KS C 3703 : 2010, Tunnel lighting standard, Korean Agency for Technology and Standards, 2010.
4 Ministry of Land, Transport and Maritime Affairs, Guidelines for road safety facility installation and management, 2008
5 Ministry of Land, Transport and Maritime Affairs, Guideline and manual for road structure and facility. 2009.
6 Narisada K., Applied research on tunnel entrance lighting in Japan, Lighting Research & Technology, Vol.7 No.2, pp.87- 90 , 1975.   DOI
7 Road Traffic Authority, The effect of alert situation on driver behaviors and physiological signal during driving, 1998.
8 Schreuder. D. A., The lighting of vehicular traffic tunnels, 119, Centrex, Eindhoven, the Netherlands, 1964.
9 Adrian W, Investigations on the required luminance in tunnel entrances, Lighting Research & Technology 1982; Vol.14, No.3, pp. 151-159.   DOI
10 CIE 26-1973, International recommendations for tunnel lighting, International Commission on Illumination, 1973.
11 CIE 61-1984, Tunnel entrance lighting : A survey of fundamentals for determining the luminance in the threshold zone, International Commission on Illumination, 1984.
12 CIE 88-1990, Guide for the lighting of road tunnels and underpass, 1st Edition, International Commission on Illumination,1990.
13 CIE 88-2004, Guide for the lighting of road tunnels and underpass, 2nd Edition, International Commission on Illumination, 2004.
14 e-Index(http://www.index.go.kr)
15 Han, J. S., Lee, M. W. and Kim, H., Measurement and analysis of adaptation luminance in the threshold zone of the road tunnels, Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol.26, No.1, pp 1-7, 2012.   과학기술학회마을   DOI   ScienceOn
16 Japanese Highway Public Corporation, Recommendation for the lighting of vehicular traffic tunnels, 1969.
17 Ketvirtis A., Visibility study for long vehicular tunnels, Journal of the Illuminating Engineering Society Vol.4 No.2, pp.120- 127, 1975.   DOI
18 Korea Expressway Corportation, Guide for the lighting of road tunnels, 2011.
19 Wout van Bommel, Tunnel lighting practice world-wide, Lighting research & technology Vol.13, No.2, pp.80-86, 1981.   DOI